1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
DANGER
2
Indicates an imminently hazardous situation which will result in
2
death or serious injury if the specified actions are not taken.
2
Compliance with the instructions is imperative.
2
WARNING
2
Indicates a potentially hazardous situation which can result in
2
death or serious injury if the specified actions are not taken.
2
Exercise extreme caution while working.
3
CAUTION
Indicates a potentially hazardous situation which can result in
4
minor or moderate injury or damage to property if the specified
4
actions are not taken.
5
5
NOTE
5
A potentially harmful situation can occur and, if not avoided, can
6
lead to property damage.
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
7
out a test run and to perform work on the electrical installation.
8
9

1.3 Basic safety rules

10
10
The safety hazards associated with the device must be assessed again
10
following installation in the final product.
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
11
increases the risk of accidents.
Note the following when working on the device:
11
; Do not perform any modifications, additions or conversions on the
12
device without the approval of ebm-papst.
12
12

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 6.3 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
·
·
·

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R3G310-AX52-90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ebm-papst R3G310-AX52-90

  • Page 1: Table Of Contents

    Note the following when working on the device: 6.1 Vibration testing ; Do not perform any modifications, additions or conversions on the 6.2 Cleaning device without the approval of ebm-papst. 6.3 Safety inspection 6.4 Disposal 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 6.3 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions R3G310-AX52-90 WARNING DANGER Live terminals and connections even with device Ejected parts switched off Missing protective devices may cause balancing weights or Electric shock broken fan blades to be ejected and cause injuries. → Wait five minutes after disconnecting the voltage at all poles →...
  • Page 3: Intended Use

    Operating instructions R3G310-AX52-90 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions R3G310-AX52-90 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Accessory part: inlet ring 31575-2-4013 with pressure tap (k-factor 116) not included in scope of delivery Max. clearance for screw 16 mm Cable diameter min. 4 mm, max. 10 mm; tightening torque 2.5 ± 0.4 Nm Tightening torque 3.5 ±...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load cycles. If you have special questions, consult ebm-papst for support. ; Use the device in accordance with its degree of protection.
  • Page 6: Mounting Data

    Operating instructions R3G310-AX52-90 Information on surface quality 4. CONNECTION AND STARTUP The surfaces of the products conform to the generally applicable industrial 4.1 Mechanical connection standard. The surface quality may change during the production period. This has no effect on strength, dimensional stability and dimensional CAUTION accuracy.
  • Page 7: Connection In Terminal Box

    Operating instructions R3G310-AX52-90 CAUTION 4.2.3 Reactive currents Voltage Because of the EMC filter integrated for compliance with EMC The fan is a built-in component and has no disconnecting switch. limits (interference emission and immunity to interference), → Only connect the fan to circuits that can be switched off with reactive currents can be measured in the supply line even an all-pole disconnection switch.
  • Page 8: Factory Settings

    Use a screwdriver to do so. When connecting, ensure that no wire ends fan out. Fig. 3: Cable routing for fans installed upright. 4.4 Factory settings Factory settings made for the device by ebm-papst. Mode parameter set 1 PWM control Mode parameter set 2...
  • Page 9: Connection Diagram

    Operating instructions R3G310-AX52-90 4.5 Connection diagram Drawing preliminary! Conn. Designation Function/assignment Protective earth terminal 1, 2, 3 L1, L2, L3 Power supply, voltage range (see nameplate), 50/60 Hz Floating status contact, break for failure floating status contact, changeover contact, common connection (2 A, max. 250 VAC, min.
  • Page 10: Checking Connections

    Operating instructions R3G310-AX52-90 4.6 Checking connections 4.8 Switching off the device ; Ensure isolation from supply (all phases). Switching off the device during operation: ; Make sure a restart is impossible ; Switch off the device via the control input.
  • Page 11: Maintenance, Malfunctions, Possible Causes And Remedies

    Din1 or by shorting remove mechanical Din1 to GND. blockage. Line voltage faulty Check line voltage, In the event of further malfunctions, contact ebm-papst. restore power supply. Attention! The error message resets 6.1 Vibration testing automatically. Device restarts Checking of fan for mechanical vibration based on ISO 14694.
  • Page 12: Cleaning

    6.4 Disposal → Do not use any pointed or sharp-edged objects for cleaning For ebm-papst, environmental protection and resource preservation are ; Completely remove any cleaning agents used. top priority corporate goals. ebm-papst operates an environmental management system which is ;...
  • Page 13 ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 51188-5-9970 · ENU · Change 212555 · Approved 2020-04-29 · Page 13 / 13 · ·...