5.1 Vibration testing

Checking of fan for mechanical vibration based on ISO 14694.
Recommendation: Every 6 months. Max. vibration severity is 3.5 mm/
s, measured at the motor fastening diameter on the motor support plate in
the direction of the motor axis of rotation and perpendicular to this.
Fig. 2: Example illustrating vibration measurement. The arrangement of
the sensors depends on the device concerned and the installation
situation.

5.2 Cleaning

To ensure a long service life, check the fans regularly for proper
operation and soiling. The frequency of checking is to be adapted
accordingly depending on the degree of soiling.
DANGER
Risk of injury from rotating fan.
→ Only clean when not in motion. Interrupt the power supply,
secure against renewed switch-on. Secure against start-up,
prevent air flow.
; Dirt deposits on the motor housing can cause overheating of the motor.
; Soiling of the impeller can cause vibration that will shorten the service
life of the fan.
; Severe vibration can destroy the fan.
; In such cases, switch off the fan immediately and clean it.
; The preferred method of cleaning is dry cleaning, e.g. using
compressed air.
; Do not use aggressive cleaning agents!
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not clean the device using a water jet or high-pressure
cleaner.
→ Do not use any acid, alkali or solvent-basedcleaning
agents.
→ Do not use any pointed or sharp-edged objects for cleaning
; Completely remove any cleaning agents used.
Item no. 16818-5-9970 · ENU · Change 210990 · Approved 2020-10-08 · Page 11 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
; If severe corrosion is visible on load-bearing or rotating parts, switch
off the device immediately and replace it.
; Repair of load-bearing or rotating parts is not permitted!
; Operate the fan for 2 hours at maximum speed so that any water that
has ingressed can evaporate.
; If cleaning does not eliminate vibrations, the fan may need to be
rebalanced. To have it rebalanced, contact ebm-papst.
; The fan is equipped with maintenance-free ball bearings. The lifetime
lubrication of the ball bearings is designed for a service life of 40,000
hours.
; If bearing replacement is necessary after that period, contact ebm-
papst.
; Adapt the maintenance intervals to the actual level of dust exposure.

5.3 Safety inspection

What to check
Contact
protection
cover for
intactness or
damage
Device for
damage to
blades and
housing
Fastening the
cables
Fastening the
protective earth
terminal
Insulation of
cables for
damage
Impeller for
wear/deposits/
corrosion and
damage
Condensation
drainage holes
for clogging,
where necessary
Abnormal
bearing noise
Vibration test

5.4 Disposal

For ebm-papst, environmental protection and resource preservation are
top priority corporate goals.
ebm-papst operates an environmental management system which is
certified in accordance with ISO 14001 and rigorously implemented
around the world on the basis of German standards.
Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.
The following section contains recommendations for ecological disposal
of the product and its components.
How to check
How often
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
acoustic
At least every
6 months
Vibration tester,
Recommended
start-up or
every 6 months
deceleration
measurement
What action?
Repair or
replacement of
device
Replacement of
device
Fasten
Fasten
Replace cables
Clean impeller
or replace device
Open holes
Replace device
Clean impeller
or replace device