DISP: Connection plug to display
FLOW: Connection plug to the flow sensor
IN: Connection plug to the input temperature sensor
OUT: Connection plug to the output temperature sensor
Model | EVT-18K |
Voltage | 240 V |
Power | 18 kW |
Min. Required Circuit Breaker Size | 2 x 40 AMP |
Max. Amperage | 75 A |
Recommended Wire Size | 2X (8AWG/2) |
Min. Water Flow to Activate the Unit | 0.475 GPM / 1.8L/min |
Safe Operating Pressure | 7.25 PSI - 108.78 PSI |
Water Connections | 3/4" NPT |
Installation | Wall Mounted |
Temperature Setting | Digital Panel |
Dimensions (LxWxH) | 17.25'' x 12.22'' x 3.43'' |
Weight | 16.53 Lbs |
Remarks:
The above wire size and circuit breaker size are for this EVT-18K unit only. If you need other highpower appliances, please do further research for that.
SIZING GUIDE
Please use the chart below to see how many gallons per minute your tankless water heater can produce with your incoming water temperature. The gallons per minute is calculated assuming 108°F outlet temperature.
Model | Inlet Temp (°F) | GPM | Suggested Usage | Outlet Temperature (°F) |
EVT-18K | 41 | 1.7 | Kitchen Faucet | 108 |
50 | 2.0 | Shower | ||
59 | 2.4 | Shower | ||
68 | 2.9 | Shower | ||
77 | 3.8 | Shower |
ATTENTION
ATTENTION
The filter is to prevent any particles from entering the unit that may clog or damage the internal parts.
If the machine is blocked, it will stop working.
ATTENTION
DO NOT disassemble the panel. There is a wire connection between the panel and the heater. If you have removed the panel, please refer to the connection diagram in COMPONENTS section to restore the wiring to the original setting.
Confirm that your breaker panel can meet the required specifications for your unit.
18k: 240V Outlet, 2x 40A Double Pole Circuit Breaker, 2x 8AWG/2 Wires
If you do not have the correct infrastructure you will need a professional to install a new outlet, breaker, and/or wiring.
Under no circumstances should you attempt to clean, install, inspect, repair, disassemble or otherwise service this water heater without first shutting off all power to the unit directly at the circuit breaker box. Serious bodily injury or death could occur if you ignore this warning.
Wait until the water is fully flowing through the heater before turning on the breaker.
If the unit is paused there may be an initial burst of very hot water when resuming. Please allow the water to flow for a few moments to let the temperature settle. It's always advised to test the water temperature with your hand before hopping straight into the shower.
Note: Do not attempt to repair this water heater yourself if the unit is not working properly. Call a technician for assistance. The power supply always needs to be shut off before these operations are carried out.
To ensure consistent Maximum performance of the unit, it is recommended to follow these instructions:
![]() | Power On/Off | ![]() | Leakage of electricity |
![]() | Decrease/Down | ![]() | Temperature exceed 149°F/65°C |
![]() | Increase/Up | ![]() | Water inlet temperature sensor failure |
![]() | Not currently working | ![]() | Water outlet temperature sensor failure |
![]() | Working state | ![]() | No over-zero signal |
![]() | Excessive water flow | ![]() | Communication failure |
Issue | Possible Reason | Solution |
Water heater is not heating at all (water is flowing but the unit is not heating - the outgoing water temperature is the same as the cold water supply) - the digital display does NOT light up. | No power or incorrect wiring. | Make sure the breakers at main electrical panel are ON. You may have a faulty breaker or unit may be wired incorrectly. |
The screen is damaged, or the screen connection is poor. | Replace the screen or reconnect the wire. | |
Water heater is heating, but the water temperature is not hot enough. | User temperature setting too low. | Turn up the temperature setting on the unit. |
Flow rate is too high. | Depending on your incoming water temperature and the power output of your model, your water flow rate may exceed the physical heating capacity of your water heater. Turn down the water flow. | |
Voltage less than 240 volts. | The set voltage of the water heater is 240v. When the voltage used is lower than 240v, the water heater will generate less heating power. It would require a larger power model. (when the voltage cannot be changed). | |
Mixing too much cold water. | You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater. You may also have an anti-scald feature on your faucet that is mixing cold water. These types of faucets can usually be adjusted to reduce the amount of cold water mixed. | |
Leakage in the joint of inlet and outlet pipe | Poor connection of inlet and outlet pipe. | Reconnect the pipe. |
The rubber washer is damaged. | Replace the washer | |
The water pressure is less and less | The inlet filter or shower is blocked by water impurities. | Remove the inlet pipe, clean the inlet filter/shower. |
Water temperature is unstable | The voltage or water pressure is unstable. | The voltage water pressure is back to normal. |
Error Code | Failure Reason | Solution |
E1 (with 5 beeps sounds) | Leakage of electricity | Stop using the water heater and let a professional pinpoint the leaking parts. |
E2 (with 5 beeps sounds) | Temperature exceeds 149°F/ 65°C. (It is a high temperature warning, not a malfunction) |
|
E3 (with 5 beeps sounds) | Water inlet temperature sensor failure | Check whether the water inlet temperature sensor terminal is effectively plugged into the main board. |
E4 (with 5 beeps sounds) | Water outlet temperature sensor failure | Check whether the water outlet temperature sensor terminal is effectively plugged into the main board. |
E5 (with 5 beeps sounds) | No over-zero signal-The user's home voltage is low or the grid input voltage abnormal. |
|
EC | Communication failure | Contact Airthereal support for assistance. |
When installing or using any high voltage electrical appliance basic safety precautions should always be followed. Under no circumstance should you attempt to clean, install, inspect, repair, disassemble, or otherwise service this water heater without first shutting off all power to the unit directly at the circuit breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL, STATE, PROVINCIAL AND LOCAL ELECTRICAL & PLUMBING CODES. PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE. FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH. This manual should be given to the homeowner after installation and should be retained for future reference.
Safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater's thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below.
The chart shown below may be used as a guide in determining the proper water temperature for your home to prevent burns.
Time/Temperature Relationship in Scalds | |
Temperature | Time To Produce a Serious Burn |
120°F | More than 5 minutes |
125°F | 1 1/2 to 2 minutes |
130°F | About 30 seconds |
135°F | About 10 seconds |
140°F | Less than 5 seconds |
145°F | Less than 3 seconds |
150°F | About 1 1/2 seconds |
155°F | About 1 second |
Households with small children, any disabled person, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with overly "HOT" water. The temperature of the water in the heater is regulated by the electronic control on the front of the water heater.
Water temperature over 125°F can cause severe burns instantly or death from scalds.
Children, disabled and elderly are at highest risk of being scalded.
See instruction manual before setting temperature at water heater.
Feel water before bathing or showering. Temperature limiting values are available, see manual.
If the hot water unit has been paused during use, you may initially get a short burst of very hot water when you turn it on again. Please run water through for a few seconds to settle down the water temperature.
Notice: Mixing valves are recommended for reducing point of use water temperature by mixing hot and cold water in branch water lines. It is recommended that a mixing valve complying with the Standard for Temperature Actuated Mixing Valves for Hot Water Distribution Systems be installed.
How to request warranty services?
To obtain the benefit of this warranty, please email support@airthereal.com. Our customer service team will address your issue as soon as possible!
Always here to help you
www.airthereal.com
Produced for: West Ryder Technology LLC
2330 Paseo Del Prado STE C304
Las Vegas, NV 89102
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Airthereal EVENING TIDE EVT-18K - WATER HEATER Manual
Advertisement
Need help?
Do you have a question about the EVENING TIDE EVT-18K and is the answer not in the manual?
Questions and answers