  • Page 1 AcclAim lED FrEsnEl User ManUal...
  • Page 2: Additional Documentation

    AcclAim lED FrEsnEl UsEr mAnUAl INTRODUCTION OUR GOAL We are committed to providing you the highest quality in customer service. Our comprehensive resources are available to help your business succeed and ensure you get the full benefit of being a Strand customer. TECHNICAL SUPPORT Our Service and Support team is tasked with online and field support, repair, demo, commissioning, mainte- nance contracts, and technical training for fixtures and systems.
  • Page 3: Safety Warnings And Notices

    AcclAim lED FrEsnEl UsEr mAnUAl SAFETY WARNINGS AND NOTICES Read this user manual in full before attempting to install, operate or maintain the fi xture to which it relates. This user manual is intended to provide general guidance to such suitably qualifi ed personnel. Installation and opera- tion of the fi...
  • Page 4: Compliance Notice

    AcclAim lED FrEsnEl UsEr mAnUAl COMPLIANCE NOTICE FCC DECLARATION OF CONFORMITY This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment.
  • Page 5: How To Obtain Warranty Service

    AcclAim lED FrEsnEl UsEr mAnUAl HOW TO OBTAIN WARRANTY SERVICE A copy of the Limited Warranty card was included in the shipping package for this product. To obtain warranty service, please contact customer service at 1-214-647-7880, or entertainment.service@ signify.com and request a Return Material Authorization (RMA) for warranty service. You will need to provide the model and serial number of the item being returned, a description of the problem or failure and the name of the registered user or organization.
  • Page 6 quality, industry standard 4.75” front lens coupled with the engineering excellence that has set Strand apart for over a century. A AcclAim lED FrEsnEl UsEr mAnUAl true theatrical Fresnel, the Acclaim LED Fresnel offers superior control and light quality to comparable PAR fixtures. The adjustable 10°...
  • Page 7: Barndoor Installation

    OVerVIeW INCLUDED ITEMS This document provides basic setup instructions and safety AcclAim lED FrEsnEl UsEr mAnUAl warnings for the following product(s): POWEr cOnnEcTOr 54108-020 912400576885 acclaim leD Fresnel (black body) QUicK sTArT 2  WArrAnTY GUiDE InsTallaTIOn acclaim leD Fresnel (white body) 54109-020 912400576886 cArD...
  • Page 8: Connecting Data And Power

    AcclAim lED FrEsnEl UsEr mAnUAl CONNECTING DATA AND POWER A maximum of 32 luminaires may be connected in any one DMX data link. A maximum of 9 luminaires may be connected in 120V, 60Hz. A maximum of 16 luminaires may be connected in 230V, 50Hz. NOTE: This maximum limit applies to the luminaire “daisy chain”...
  • Page 9: Menu Operation

    MOUNTING The unit should be mounted via its screw holes on AcclAim lED FrEsnEl UsEr mAnUAl the bracket. Always ensure that the unit is fi rmly fi xed to avoid vibration and slipping while operating. Always ensure that the structure to which you are 3 ...
  • Page 10 AcclAim lED FrEsnEl UsEr mAnUAl LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT address 001~512 8 - Bit (Default) DMX Mode 16 - Bit Ch 1 - Intensity XXX (Value) Data Ch 2 - Intensity Fine XXX (Value) ……all functions DMX Hold (Default...
  • Page 11 AcclAim lED FrEsnEl UsEr mAnUAl LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT (no errors... or displays a status Give list of fi xture errors list of errors) Fan Check Give fans speeds Diagnostics Temp Give leD / Fixture temperatures Version VXXX (MM/DD/YY...
  • Page 12: Manual Menu

    AcclAim lED FrEsnEl UsEr mAnUAl NOTE: Not all menu options are available for every fi xture. DMX MENU Choose DMX, press the ENTER button to confirm, use the UP/DOWN button to choose from options listed. ADDRESS Choose Address, press the ENTER button to confirm. Use the UP/DOWN button to select range of values. Press the ENTER button to store.
  • Page 13 AcclAim lED FrEsnEl UsEr mAnUAl OUTPUT MODe Choose Output Mode, press the ENTER button to confirm. Use the UP/DOWN button to select Standard, Studio, or Whisper. Press the MENU button to return to previous menu. COlOr CalIBraTIOn Choose Color Cal, press the ENTER button to confirm. Use the UP/DOWN button to Choose ON or OFF. Press the MENU button to return to previous menu.
  • Page 14 AcclAim lED FrEsnEl UsEr mAnUAl NOTE: Incoming DMX must be removed from the fixture or software crossload will not be activated. PASSWORD Select Password(2606), press the ENTER button to confirm. Use the UP/DOWN button to select White Balance or Change Mode, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 15: Dmx Mapping

    AcclAim lED FrEsnEl UsEr mAnUAl 4  DMX MaPPInG The fixture can be operated by DMX controller. The following tables assumes a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in se- quence.
  • Page 16 AcclAim lED FrEsnEl UsEr mAnUAl COLOR PRESET CCT TARGET CRI (RA) 2700K 82.3 3200K 84.4 4500K 5600K 85.8 6500K 85.2 7000K 84.4 7472K 82.2 W W W.VA R I - L I T E .C O M...
  • Page 17 AcclAim lED FrEsnEl UsEr mAnUAl 5  rDM ParaMeTer IDs Remote Device Management (RDM) is a protocol enhancement to USITT DMX512 that allows bi-directional com- munication between a lighting or system controller and attached RDM compliant devices over a standard DMX line.
  • Page 18 AcclAim lED FrEsnEl UsEr mAnUAl ESTA DMX / UI RDM PARAMETER IDS VALUE COMMENT REQUIRED / ALLOWED ALLOWED STANDARD DESCIPTION Category - network Management DIsC_UnIQUe_BranCH 0x0001 DIsC_MUTe 0x0002 DIsC_Un_MUTe 0x0003 PrOXIeD_DeVICes 0x0010 PrOXIeD_DeVICes_COUnT 0x0011 COMMs_sTaTUs 0x0015 Category - status Collection QUeUeD_MessaGe 0x0020 sTaTUs_MessaGes...
  • Page 19 AcclAim lED FrEsnEl UsEr mAnUAl ESTA DMX / UI RDM PARAMETER IDS VALUE COMMENT REQUIRED / ALLOWED ALLOWED STANDARD DESCIPTION   Dimmer Curve Description 0x0344 Modulation Frequency 0x0347   Modulation Frequency 0x0348 Description Category - Power / lamp settings 0x04xx DeVICe_HOUrs 0x0400 Fixture Hours...
  • Page 20 AcclAim lED FrEsnEl UsEr mAnUAl ESTA DMX / UI RDM PARAMETER IDS VALUE COMMENT REQUIRED / ALLOWED ALLOWED STANDARD DESCIPTION Value range auto shutdown Mode 0x8aa4 depends on options leD Hours 0x8aa5 Dim snap (On/Off ) 0x8aa6 Color snap (On/Off ) 0x8aa7 auto Fan Mode (On/Off...
  • Page 21: Care And Maintenance

    AcclAim lED FrEsnEl UsEr mAnUAl Appendix A  CARE AND MAINTENANCE TROUBLeSHOOTinG The following are a few common problems that may occur during operation. Luminaire does not work; light and fan do not turn on. • Check power connection and main fuse. •...
  • Page 22: Fan Speed And Control

    AcclAim lED FrEsnEl UsEr mAnUAl Appendix B  FAN SPEED AND CONTROL FAN SPEED AND CONTROL All Vari-lite luminaires will be governed by the same Fan speed v Noise levels v Maximum power output rules as details below. These noises related to these levels will confi...
  • Page 23 AcclAim lED FrEsnEl UsEr mAnUAl This page intentionally blank W W W.VA R I - L I T E .C O M...
  • Page 24: Technical Support

    TECHNICAL GLOBAL 24HR TECHNICAL SUPPORT: Call: +1 214 647 7880 SUPPORT entertainment.service@signify.com NORTH AMERICA SUPPORT: Call: 877-VARI-LITE (877-827-4583) entertainment.service@signify.com EUROPEAN CUSTOMER SERVICE CENTER: Call: +31 (0) 543 542 531 entertainment.europe@signify.com ©2023 Signify Holding. All rights reserved. All trademarks are owned by Signify Holding or their respective owners. The information pro- vided herein is subject to change, without notice.