Wind sensor with converter Safety instructions Electrical devices may be mounted and connected only by electrically skilled persons. Serious injuries, fire or property damage are possible. Please read and follow the manual fully. Danger of electric shock. Always disconnect before carrying out work on the device or load.
Wind sensor with converter Intended use – The converter and wind sensor are used to protect a blind/shutter against de- struction due to excessively strong winds. The blind/shutter is moved to a safe end position and locked there until the wind drops below the set wind speed value.
Page 5
Wind sensor with converter ■ Remove the housing lid of the converter by slackening the two screws (3). ■ For rear cable insertion, penetrate the rubber sheath (6) and insert the cable (see figure 3). Figure 3: Converter connection compartment ■ Fasten the device using two screws (10).
Wind sensor with converter Commissioning DANGER! Electric shock when live parts are touched. Electric shocks can be fatal. During commissioning, cover the parts carrying voltage on the device and in their surrounding area. Switching the wind detector switch in the converter ■...
SELV limit value AC 24 V~ Warranty The warranty is provided by the specialist trade in accordance with statutory require- ments. ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon: +49 2355 806-0 Telefax: +49 2355 806-204 kundencenter@jung.de...