  • Page 1 INTENSITY™ Select Combo II INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II This manual is valid for the Table of Contents Select Combo II Introduction ........4 1.1 General...
  • Page 3: Introduction

    Stimulation (TENS). TENS is intended to help relieve pain. The TENS unit sends comfortable impulses through the skin to stimulate the nerve (or The InTENSity Select Combo II stimulator is a portable electrotherapy nerves) in the treatment area. In many cases, this stimulation will greatly device featuring four therapeutic modes: Transcutaneous Electrical reduce or eliminate the pain sensation the patient feels.
  • Page 4: Indication For Use

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II EXPLANATION OF IF 1.3 Indication for use Select Combo II Stimulator may be used for the following conditions: treatment modality. Interferential stimulation is characterized by 1) Symptomatic relief of chronic intractable pain.
  • Page 5 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II DO NOT USE ON THESE INDIVIDUALS Contraindications • Pregnant women, because the safety of electrical stimulation during This stimulator must not be used in combination with the following medical pregnancy has not been established.
  • Page 6 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II CAUTION CAUTION (CONTINUED) WARNINGS AND PRECAUTIONS REGARDING THE PADS CAUTION WHILE USING THE STIMULATOR • United States Federal Law restricts this device to sale by or on the order of a •...
  • Page 7 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II GENERAL PRECAUTIONS POSSIBLE ADVERSE REACTIONS • The long-term effects of electrical stimulation are unknown. • Do not use to treat one region for extended periods of time (more than 30 minutes a session, up to 2 times/day) or muscles in that region may become •...
  • Page 8: Package Contents

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 3.1 Front and Rear Panel 3. PACKAGE CONTENTS Select Combo II Select Combo II Unit 2 × Lead wires 4 × Electrode pads (2" x 2")
  • Page 9: Lcd Display

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 3.2 LCD Display 4. SPECIFICATIONS 4.1 Technical Information 12 11 Channel Dual, isolated between channels Power Supply 3.7V LI rechargeable battery pack Charger output: 5.0V DC, 300mA (optional) Operating Conditions 5°C to 40°C (41°F to 104°F) with a relative...
  • Page 10: Program Parameters

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 4.2 Program Parameters Program Parameters (Continued) TENS NMES Body Treatment Pulse Pulse Contract Relax Ramp Body Treatment Pulse Pulse Cycle Program Program Part Time Rate Width...
  • Page 11 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 4.2 Program Parameters (Continued) IF (Sweep) IF (Sweep) Treatment Pulse Cycle Body Part Program Carrier F Beat Low Beat High Time Width Time 20 Min. 10,000Hz 100µs...
  • Page 12 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 4.2 Program Parameters (Continued) RUSSIAN (RUSS) RUSSIAN (RUSS) Treatment Carrier Pulse Burst Ramp Body Part Program Burst Time Contraction Relaxation Time Width Up/Down Burst/interval 10ms each 15 Min.
  • Page 13: Waveform Information

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 4.3 Waveform Information (Continued) 4.3 Waveform Information NMES TENS Synchronous Continuous intensity time Pulse Width Modulation IF (Interferential) Cycle time Pulse Rate Modulation RUSSIAN (RUSS) Cycle time...
  • Page 14: Instruction For Use

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 5. INSTRUCTIONS FOR USE 5.1 Battery Installation of Battery Push down on the belt clip to release it. Remove the battery cover and insert the battery, as shown on the diagram. Replace the battery cover and belt clip.
  • Page 15: Turn On The Device

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II Manual TENS Program — U1 5.4 Turn on The Device Press the [ ] button to turn on the device. A. Select Body Part Press the “M/II” button to choose TENS mode. Then select the body part which you want to treat.
  • Page 16 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II D. Set Pulse Width Manual NMES Program — U1 Press [ S ] button to enter the pulse width and the “µs” will flash. Then A. Select Body Part −...
  • Page 17 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II D. Set Pulse Width Press [ S ] button to enter the pulse width and the “µs” will flash. Then − press [ ] or [ ] button to adjust the pulse width.
  • Page 18 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II C. Start Treatment Press [CH1+] or [CH2+] to increase the output intensity of channel 1 and/or channel 2. Press [CH1−] or [CH2−] to decrease the output intensity of channel 1 and/or channel 2.
  • Page 19 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II Set Preset IF (Interferential) Program — P1 or P2 Manual RUSS (Russian) Program — U1 A. Select Body Part A. Select Body Part Press the “M/II” button to choose IF mode. Then select the body part Select the body part which you want to treat.
  • Page 20 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II C. Set Ramp Up Time Set Preset RUSS Programs — P1 and P2 Press [ S ] button to set the ramp up and down time and the “sec.”...
  • Page 21: Turn Off Device

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II Low Battery Indicator CAUTION When the low power indicator " " displays on the LCD, stop the 1) If the electrodes are not placed firmly on skin or the device has not device and charge the battery.
  • Page 22: Patient Compliance Meter

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 5.8 Patient Compliance Meter 6. CLEANING AND STORAGE You can store 90 sets of treatment records and a total treatment time of up to 100 hours on this device.
  • Page 23: Storing The Electrode Pads And Lead Wires

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 7. TROUBLESHOOTING CAUTION Problem Possible Causes Possible Solution 1) The life of electrodes may vary by the frequency of washing, Are the batteries Charge or replace the skin condition, and storage state.
  • Page 24: Disposal

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 7. TROUBLESHOOTING (Continued) 8. DISPOSAL Problem Possible Causes Possible Solution Used fully discharged batteries must be disposed of in a specially labeled collection container, at toxic waste...
  • Page 25: Electromagnetic Compatibility (Emc) Tables

    Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II 10. ELECTROMAGNETIC COMPATIBILITY Guidance and manufacturer's declaration — (EMC) TABLES electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is or provided by the manufacturer of this equipment could result in used in such an environment.
  • Page 26 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II Guidance and manufacturer’s declaration- Voltage dips, <5% UT <5% UT Mains power quality Electromagnetic immunity short (>95% dip in UT) (>95% dip in should be that of a interruptions for 0.5 cycle...
  • Page 27 Compass Health Brands Compass Health Brands InTENSity Select Combo II InTENSity Select Combo II Recommended separation distances between Interference may occur in portable and mobile RF communications equipment and the device . the vicinity of equipment marked with the following...
  • Page 28: Warranty

    Compass Health Brands InTENSity Select Combo II 11. WARRANTY Please contact your dealer or the device center in case of a claim under the warranty. If you have to send in the unit, enclose a copy of your receipt and state what the defect is. The following warranty terms apply: 1) The warranty period for device is one year from date of purchase.