Gossen MetraWatt PROFITEST EMOBILITY Operating Instructions Manual
Gossen MetraWatt PROFITEST EMOBILITY Operating Instructions Manual

Gossen MetraWatt PROFITEST EMOBILITY Operating Instructions Manual

Adapter for standards-compliant testing of single and 3-phase, mode 2 and 3 charging cables
Hide thumbs Also See for PROFITEST EMOBILITY:

Advertisement

Quick Links

Operating Instructions
PROFITEST
E
MOBILITY
Adapter for Standards-Compliant Testing of Single and 3-Phase,
3-349-981-15
Mode 2 and 3 Charging Cables
7/2.24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROFITEST EMOBILITY and is the answer not in the manual?

Questions and answers

Summary of Contents for Gossen MetraWatt PROFITEST EMOBILITY

  • Page 1 Operating Instructions PROFITEST MOBILITY Adapter for Standards-Compliant Testing of Single and 3-Phase, 3-349-981-15 Mode 2 and 3 Charging Cables 7/2.24...
  • Page 2: Table Of Contents

    Table of Contents Page Table of Contents Page Safety Instructions........3 Measuring RC (Testing of Resistance Coding) Application ..........4 (not possible with SECUTEST ST PRO) ..16 2.1 Intended Use / Use for Intended Purpose ..4 Storage and Transport ......16 2.2 Use for Other than Intended Purpose .....5 Maintenance ..........
  • Page 3: Safety Instructions

    Gossen Metrawatt GmbH are designed connected to any of the sockets. such as to ensure optimum compatibility • Measurements within electrical systems with the Gossen Metrawatt GmbH prod- are prohibited. ucts that are expressly provided for • Observe the manufacturer’s specifica- them.
  • Page 4: Application

    Intended Use / must not necessitate any undue force. Use for Intended Purpose • Never touch conductive ends (e.g. of The PROFITEST EMOBILITY is an adapter test probes). for standards-compliant testing of single and • Do not touch the insulation measuring 3-phase, mode 2 and 3 charging cables with instrument’s test probes during insula-...
  • Page 5: Use For Other Than Intended Purpose

    (including excerpts) are only permissible after Liability and guarantee granted by Gossen previously obtaining written consent from Metrawatt GmbH complies with the applica- Gossen Metrawatt GmbH. This applies in ble contractual and mandatory legal regula- particular to storage and processing in elec- tions.
  • Page 6: The Instrument

    The Instrument The Instrument Scope of Delivery Please check the scope of delivery for com- pleteness and intactness. 1 Test adapter PROFITEST EMOBILITY (M513R) in case 1 Mains power cable 1 Set of operating instructions (this docu- ment) Optional Accessories...
  • Page 7: Connections Overview

    The Instrument Connections Overview 1 N2: Input sockets for 3-phase mains 6 ICCB-OUT1*: Charging cable output sock- connection with the help of a CEE ets wired parallel to OUT2 for connecting adapter (16 A, 32 A with five 4 mm a test instrument for protective conduc- safety sockets) and mains connection tor and insulation measurement...
  • Page 8: Operating Overview

    The Instrument Operating Overview Top Switch Mains connect, mode 2 charging cable Status B, C, E – for fault simulation – for R measurement – for tripping test with I and measurement of time to trip Mains disconnect, mode 2/3 charging cable Riso –...
  • Page 9: Technical Data

    The Instrument Technical Data Mechanical Design Protection Housing: IP40 Terminals – test outlets (protection against Earth contact IN4: ingress of solid for- 1P+N+PE, 0.8 A, eign objects: 230 V  1.0 mm diameter, 3P+N+PE IN2/OUT2: protection against 0.8 A, 400 V ingress of water: not protected) Power Supply...
  • Page 10: Initial Startup

    Initial Startup Initial Startup See the connections overview for all con- Testing the LEDs nection variants on page 7. Single-Phase Mains Connection ➭ Insert the earthing contact plug into the Mains Connection earthing contact mains outlet, remove it, The test adapter must be connected to the rotate it 180°...
  • Page 11: Fault Simulation

    Fault Simulation Fault Simulation Mode 2 and 3 charging cables can be tested 6.1.2 Simulated Interruption with the test adapter with simulation of faults. ➭ Start with the bottom rotary selec- tor switch (S2) in the first ON position in Attention! the orange area for single-phase inter- In any case, comply with the manu-...
  • Page 12: Mode 2 (3-Phase) Charging Cable

    Fault Simulation Mode 2 (3-phase) Charging Cable ➭ Switch mains voltage on by turning the top rotary selector switch (S1) to the Status C position (system state: vehicle ready for charging). 6.2.1 Simulated Interruption ➭ Start with the bottom rotary selector switch (S2) in the first ON position in the green area for single-phase interruption.
  • Page 13: Measurements/Tests With Test Instruments

    Measurements/Tests with Test Instruments Measurements/Tests with Test PROFITEST MF XTRA, PROFITEST MF TECH, PROFITEST MXTRA, PROFITEST MXTRA IQ, Instruments PROFITEST MTECH+, PROFITEST MTECH+ IQ: General Information 2-pole measuring adapter When connecting a compatible test instru- PROFITEST PRIME, PROFITEST PRIME AC: ment, additional measurements/tests are probes L(1) and PE(3) possible which are described in this chapter.
  • Page 14: Charging Cable (Not Possible With Secutest St Pro)

    Measurements/Tests with Test Instruments SECUTEST ST PRO: 2-pole measurement We recommend the following procedure in with test probes P1 and P2 (P1-P2) order to prevent an upstream RCD (selective ➭ Connect the test object as described in RCD as well) from tripping, and to ensure that actual tripping current or correct time to chapter 5.3.
  • Page 15: Guided Test Sequences (Not Possible With Profitest Mxtra And Profitest Mtech+)

    Protective Conductor Current Measurement (IPE) at Mode 2 Charging Cable Guided Test Sequences Protective Conductor Current (not possible with PROFITEST MXTRA Measurement (I ) at Mode 2 and PROFITEST MTECH+) Charging Cable Test sequences are available for the test Protective conductor current or bias current instruments.
  • Page 16: Measuring Rc (Testing Of Resistance Coding) (Not Possible With Secutest St Pro)

    Measuring RC (Testing of Resistance Coding) (not possible with SECUTEST ST PRO) Measuring R Storage and Transport (Testing of Resistance Coding) (not possible with SECUTEST ST Attention! PRO) Improper Storage Damage to the product and measur- Testing of specified resistance value R ing error due to environmental influ- maximum current-carrying capacity of the ences...
  • Page 17: Maintenance

    Maintenance Maintenance 11.2.1 Testing of Protective Conductor Resis- tance R 11.1 Cleaning of Housing Test Adapter Contacting, Single-Phase (230 V) Protective conductor resistance is tested Attention! between the PE contact at the mains plug Life endangering due to electric (inlet plug N1) and PE contacts ICCB IN1 shock! through IN4.
  • Page 18: Fuse Replacement

    Maintenance Testing the 3-Phase Connection • at the power supply end of the test ➭ Turn the top rotary selector switch (S1) at object, ICCB-IN1 the test adapter to the Status C position • at the output end of the test object, ICCB- (system state: vehicle ready for OUT1 charging).
  • Page 19: Repair

    Repair F1, F2 and F3 (3-phase mains supply power sys- Repair tem N2) If your instrument requires repair, please Required materials: contact our service department, see “Con- – A slotted screwdriver for opening the tact, Support and Service” on page 20. fuse compartment –...
  • Page 20: Contact, Support And Service

    Contact, Support and Service Contact, Support and Service CE Declaration Gossen Metrawatt GmbH can be reached The instrument fulfills all requirements of directly and simply – we have a single num- applicable EU directives and national regula- ber for everything! Whether you require sup- tions.
  • Page 21: Disposal And Environmental Protection

    (including recharge- Attention! able batteries) used in Germany can be Environmental Damage returned free of charge to Gossen Metrawatt Improper disposal results in environ- GmbH or the service provider responsible mental damage. for their disposal in compliance with applica-...
  • Page 22 ©Gossen Metrawatt GmbH Prepared in Germany • Subject to change / errors excepted • A pdf version is available on the Internet All trademarks, registered trademarks, logos, product names and company names are the property of their respective owners. Gossen Metrawatt GmbH Phone +49 911 8602-0 Südwestpark 15...