HATHASPACE HARMONY 600 (HSE600) - HEPA Air Purifier Manual

HATHASPACE HARMONY 600 (HSE600) - HEPA Air Purifier Manual

Also See for HARMONY 600:

Advertisement

HATHASPACE HARMONY 600 (HSE600) - HEPA Air Purifier Manual

Introduction

NOTE:
Remove plastic bag from filter before use


READ AND SAVE THESE INSTRUCTION
Use unit according to instructions provided in the manual. Keep this manual for future reference.
This appliance can be used by children aged 8 years and above and individuals with reduced physical, sensory, mental capabilities, or lack of experience if they've been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.

Basic Information

Model HSE600
Power Supply 120V/60HZ
Rated Power 40W
CADR 88 CFM
Noise Level 24dB-50 dB
Dimensions 205*205*313mm 8.07*8.07*12.32inch
Net Weight 2.35 KG

Product Diagram

Product Diagram

4-in-1 Purification System

4-in-1 Purification System
Your new Hathaspace Air Purifier uses advanced technology to clean the air in your room.
Uses 4 advanced technologies to keep your air clean, capturing airborne particles:

  1. Polypropylene Pre-filter
    A preliminary Polypropylene Pre-filter removes large particles like pet hair, dust, and floating debris. This helps extend the life of the composite filter.
  2. Pre-filter
    Non-woven materials serve as an extra pre-filter, capturing small corrosive particles to extend the life of the H13 HEPA filter.
  3. Activated carbon filter
    Activated carbon absorbs smoke, odors. and gases in the air.
  4. H13 HEPA filter
    This high-efficiency HEPA filter can capture small micron particles. These smaller particles make up the majority of harmful air pollutants like tobacco smoke and lead dust.

Buttons and Indicators

Control Panel

Buttons and Indicators - Control Panel

No. Icon Function
1 Power on/off
2 Timer button: 1/2/4/8h
3 Fan speed buttons: Sleep mode, Levels 1, 2, 3
  • Press the speed button to choose sleep mode. In sleep mode, all other indicator lights are turned off.
4 Filter reset button
  • After the unit has been used for 2000 hours, the unit will remind the user to replace the filter when it is powered on each time.
5 AUTO button and child lock button
  • Short press the auto button to enter auto mode, and long press 3 seconds to enter child lock mode. In Auto mode, the fan speed will automatically adjust according to the air quality.
6 Light turn/off button
7 Brightness Adjustment button
8 Air quality indicator (Green, yellow, red)
  • When on auto function, the color of the light will change based upon the air quality.

Air Quality Indicator

Index (ug/m 3 ) Air Quality Speed Color

PM2.5
0-75 Good 1 Green
75-150 Moderate 2 Yellow
150-500 Unhealthy 3 Red

Particle Sensor

Mode Operation
Particle Sensor Manual Mode Adjust fan speed based on your needs. Using the Air Quality Indicator, change the fan speed from 1 (low) to 3 (high) depending on the air quality.
Auto Mode Purify the air automatically at different fan speeds based on the air quality detected by the sensor.

Note: Clean the appliance regularly with soft brushes, eg. a makeup brush.

Brightness Adjustment

There are three levels of light brightness:

  • The default brightness of lights is 100% (including all indicators and air quality lights)
  • Press the brightness adjustment button to manually adjust the following air quality indicator light levels: 30% » 60% » 100% » 30%
  • The brightness is not memorized after the light is adjusted and will still be 100% when the machine is turned on next time (unless you press and hold the brightness key for 3 seconds to set the memory brightness setting)
  • After adjusting the brightness of the light, long press the brightness key for 3 seconds to set the memory light brightness (ex. to set 30%, long press for 3 seconds and the light brightness will be 30% after the next startup)

Air Purifier Maintenance

Cleaning the Unit

  • Please turn off the power and unplug it before cleaning the air purifier.
  • To remove dust, lightly wipe the unit with a soft, clean cloth. If needed, wipe the unit with a clean damp cloth, then immediately dry it with a clean dry cloth. Don't use alcohol, oil, or benzene to clean the unit
  • Do not immerse the unit in water

Note: The HEPA filter, gray color non-woven pre-filter, and the activated carbon filter cannot be reused, cleaned, or replaced after being used. Please don't wash them with water.

Replacing the filter

To maintain the air purifier's performance and purification effect, we suggest replacing the filters every 3-4 months or 2000 hours.

  1. Unplug the air purifier from the electrical outlet.
  2. Twist the bottom panel counterclockwise to remove the panel.
    Replacing the filter - Step 1
  3. Remove the old filter and dispose of it properly. The filter is not recyclable.
    Replacing the filter - Step 2
  4. Remove the new filter packaging and insert it into the air filter.
  5. Turn it clockwise to tighten the bottom panel.
    Replacing the filter - Step 3
  6. Place the air filter on the table again and plug it back into the electrical outlet. The air purifier will automatically clean the air again.

Note:

  • The actual replacement frequency depends on use and air quality. If it is on day and night or your surrounding air is highly polluted, it will need to be replaced sooner.
  • Please remember to press the "Filter Reset " button for 3 seconds to reset the air purifier, otherwise, the filter light will keep blinking.

Troubleshooting

Problem Reasons Possible Solution
Air purifier cannot be turned on or respond to button controls.
  1. No electricity.
  2. Power cord is damaged.
  3. The outlet is damaged.
  4. The air purifier malfunctioned.
  1. Check that the unit is properly plugged into an electrical outlet.
  2. Contact Customer Service.
  3. Plug into a different outlet.
  4. Contact Customer Service.

Airflow is significantly reduced

  1. The airflow is blocked by packaging.
  2. A low speed is being used.
  3. There is not enough clearance for the air inflow.
  4. The Pre-filter may be clogged by large particles.
  5. Filters are installed incorrectly.
  1. Remove the packaging.
  2. Increase the fan speed.
  3. Leave 20cm clearance on all sides of the air purifier.
  4. Clean the Pre-filter or replace the filter.
  5. Make sure the filters are installed correctly.
Air purifier makes an unusual noise while the fan is on.
  1. The airflow is blocked by packaging.
  2. The air purifier is on an inclined place making the fan blades rub with the air purifier's lining.
  3. The air purifier may be damaged or a foreign object may be inside.
  1. Remove the packaging.
  2. Put the air purifier on even places.
  3. Contact Customer Service.

Strange smell comes from the purifier

  1. The airflow is blocked by packaging.
  2. The air purifier is on an inclined place making the fan blades rub with the air purifier's lining.
  3. The air purifier may be damaged or a foreign object may be inside.
  1. Remove the packaging.
  2. Put the air purifier on even places.
  3. Contact Customer Service.

Poor air purification quality

  1. A low speed is used.
  2. The airflow is blocked by packaging.
  3. The air outlet is blocked.
  4. Filters installed incorrectly.
  5. Is being used in open places.
  6. The applied area is larger than the effective range.
  7. The quality of the air in the room is very poor.
  8. The room layout is not good.
  1. Increase the fan speed.
  2. Remove the packaging.
  3. Remove any matter that is blocking the air outlet.
  4. Make sure the filters are installed correctly.
  5. Close doors and windows while using the air purifier.
  6. Consider a larger air purifier.
  7. Open the window to circulate new air.
  8. Buy more air purifiers or change the layout if possible.

Air purifier always detects high levels of particulates

  1. The unit is operating in a very dusty environment.
  1. Consider turning the fan to HIGH.
The filter light is still on after replacing the filter.
  1. Forgot to reset the air purifier.
  1. Press the "Filter Light" button for 5 seconds.

The filter light doesn't turn on within 8 months

  1. The appliance has been running infrequently.
  1. Not Applicable.

The filter light is on before 6 months

  1. The appliance is run frequently or the air is highly polluted.
  1. Replace the filters.

Customer Support

Hathaspace cherishes your experience. If you have any questions or concerns about your air purifier, please feel free to contact our customer support team.
Email: team@hathaspace.com
Website: https://hathaspace.com

www.hathaspace.com
team@hathaspace.com
1-800-446-0535

Hathaspace

Safety Instructions

This appliance is a desktop air purifier. To reduce the risk of fire, electric shock, or serious injury, basic safety precautions should always be followed when using electrical appliances. Please read and follow all the safety instructions before using and only use this air purifier as described in this manual.
This appliance has a polarized plug, which means that one blade is wider than the other. To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to bypass this safety feature.

To reduce the risk of fire, electric shock or injury to persons, do not use replacement parts that have not been recommended by the manufacturer (e.g. parts made at home using a 3D printer).

  • Do not use the air purifier in wet or humid environments, or outdoors. This appliance is designed for indoor use only.
  • Do not put the air purifier on an uneven floor such as a bed or sofa. Always make sure to place the air purifier on a flat surface before operating. Leave more than 20 cm distance between the air purifier and the wall.
  • Do not place the air purifier near sources of heat, such as stove tops, ovens, or radiators.
  • Do not handle the unit with wet hands. Thoroughly dry your hands before handling any part of the air purifier.
  • Do not use without removing the plastic wrap from the air purifier and filters.
  • Do not attempt to use other filters with this appliance. Only use Hathaspace air replacement filters for this unit.
  • Do not block the air inlet, outlet, or sensor.
  • Do not insert fingers or objects into the air outlet.
  • Do not immerse the air purifier in liquids or clean the appliance with any liquid to avoid electric shock and/or electrical fires.
  • Do not run the power cord under carpeting, rugs, furniture, or appliances. Place the power cord away from high-traffic areas.
  • Do not operate the unit if the power cord or plug is damaged. Doing so may result in injury or damage to the unit.
  • Do not repair the air purifier by yourself if it does not work; it will void your warranty. If your appliance is no longer working, damaged, or not functioning properly, discontinue use, unplug immediately and contact customer support.
  • Do unplug the appliance from the power supply before servicing.
  • Do inspect the unit frequently. Dirt that has been collected should be removed regularly to prevent excessive accumulation that may result in flashover or fire.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download HATHASPACE HARMONY 600 (HSE600) - HEPA Air Purifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the HARMONY 600 and is the answer not in the manual?

Questions and answers

Table of Contents