Installation; Stove Placement; Floor Protection Requirements - Cumberland Stove Works MF3700 Operator's Manual

Cumberland stove works mf3700,mf3800 multi fuel parlor stove installation and operation
Hide thumbs Also See for MF3700:
Table of Contents

Advertisement

INSTALLATION

It is recommended that the stove be installed and serviced
by authorized professionals who are certified by the National
Fireplace Institute (NFI) as NFI Pellet Specialists.
Proper installation of this stove is necessary for safe and
efficient operation. Installing this product improperly may
result in a house fire and personal injury. All applicable
building codes for your location must be followed. In areas
where building codes require additional steps to the
installation of this product not included in this manual, the
building codes have precedence and must be followed.
Contact your local building inspector to obtain any
necessary permits or inspection guidelines before installing
the product.

STOVE PLACEMENT

Sketch out a plan for installing the stove including dimensions
before permanent placement. When determining the
location for the stove, wall stud location is critical. You may
need to adjust the location of the stove to avoid trying to
vent through a wall stud. Before placing the parlor stove,
connect the vent and allow for minimum clearance to
combustible walls.

FLOOR PROTECTION REqUIREMENTS

The stove must be installed on a noncombustible floor, with
proper floor protection, or on a masonry hearth. The hearth
or noncombustible floor protector must extend a minimum
of six inches (6") in front, and four inches (4") from each
side. When a cleanout t-vent is installed in the inside of
a home, the floor protector must extend 2" beyond rear of
t-vent. SEE FIGURE 13. When stove is vented straight
through the wall and the cleanout t-vent is on the exterior
of the home, the minimum clearance is 3" from the back
of the stove to the edge of floor protector. SEE FIGURE
14. The minimum floor protector material is 24 gA. sheet
metal.
2"
4"
4"
6"
Figure 13
PARLOR STOVE FLOOR PAD CLEARANCES
Page 1
3"
4"
4"
6"
Figure 14
CumberlandStoveWorks.com
INSTALLATION AND OPERATION MANUAL
WARNING
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL
AND USE THIS STOVE. FAILURE TO FOLLOW THE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
CHILDREN AND ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE TEMPERATURES
AND SHOULD STAY AWAY TO AVOID BUMPS TO SkIN
AND/OR CLOTHING.
YO U N G C H I L D R E N S H O U L D B E C A R E F U L LY
SUPERVISED WHEN THEY ARE IN THE SAME ROOM
AS THE STOVE.
CLOTHING AND OTHER FLAMMABLE MATERIALS
SHOULD NOT BE PLACED ON OR NEAR THIS UNIT.
CAUTION
THIS STOVE SHOULD NOT BE USED AS THE ONLY
SOURCE OF HEAT IN THE HOUSE. POWER OUTAGES
AND PERIODIC MAINTENANCE WILL RESULT IN A
TOTAL LOSS OF HEAT.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION
REqUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS
MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT,
FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE
NEED FOR A PERMIT.
kEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS,
LEAVES, ETC.) AT LEAST THREE (3) FEET AWAY
FROM THE FLUE OUTLET ON THE OUTSIDE OF THE
BUILDING.
INSTALLATION AND REPAIR OF THIS PARLOR STOVE
SHOULD BE DONE BY A qUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A qUALIFIED
SERVICE PERSON. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, FIRE BOX, AND CIRCULATING AIR
PASSAGEWAYS OF THE STOVE BE kEPT CLEAN.
Models MF3700, MF3800