mF3800 TroubleshooTing guide
unplug stove before performing any maintenance. neVer TesT or CheCK eleCTriCAl ComPonenTs un-
less sToVe is unPlugged From PoWer suPPlY.
Problem
Stove Will Not Feed Pellets
Problem
Fire goes out or Stove Shuts
down
Contact service provider if above remedies fail. Contact your dealer or call CsW
customer service at 800-345-6007.
WArning! negative pressure in a home is a serious issue. if there is a problem,
the stove should be installed with a Fresh Air Kit (not included).
Page 
display status
No readiNg
Normal readiNg
display status
loSS oF Fire
oFF To reSeT
overTemP reSeT SWiTCH
auger overTemP
vaCuum FaulT
CHeCk SealS
CumberlandstoveWorks.com
TroubleshooTing Addendum
Possible causes
No power
defective control head
Hopper is empty
Hopper lid is open
Pellet and/or auger jam
auger motor failure
Hopper switch failure
Possible causes
Hopper is empty
Poor quality fuel
Power supply interrupted
Plugged firepot
overtemp
loose connection on spade
terminal
overtemp
loose connection on spade
terminal
inadequate door seals
Front door is ajar
ash pan is ajar
vacuum switch hose is loose/
disconnected, or switch is broken
Model MF3800
remedy
Check to see if stove is plugged in
Check communication cable
Check electrical outlet for power
Check fuse on incoming red power
wire
Test and replace control head if
needed
add fuel to hopper
Close hopper lid
Check auger for fines or pellet jam
replace auger motor
Bypass switch to test. replace
hopper switch if needed
remedy
add fuel to hopper
Change fuel supplier/moisture test
corn
Check power supply. go through
re-ignite sequence
Clean firepot. Clear all holes of ash
or debris
allow stove to cool and reset switch
Check connections on switch and/or
lower plug on im
allow stove to cool and reset fuel
shutoff.
Check connections on switch and/or
lower plug on im
Check that rope seals are in working
condition
Close door securely
Secure ash pan in its proper position
make sure vacuum switch hose is
attached to the switch. replace
switch if necessary.
TSgmF3800
Troubleshooting guide addendum
rev. 06/03/10
© 2010 ardisam, in
all rights reserved.
800-345-6007

Advertisement

loading

Summary of Contents for Cumberland Stove Works MF3800

  • Page 1 TroubleshooTing Addendum Model MF3800 mF3800 TroubleshooTing guide unplug stove before performing any maintenance. neVer TesT or CheCK eleCTriCAl ComPonenTs un- less sToVe is unPlugged From PoWer suPPlY. Problem display status Possible causes remedy No power Check to see if stove is plugged in...