Download Print this page

Advertisement

Quick Links

Libretto di Istruzioni
Instructions Manual
Manuel d'Instructions
Bedienungsanleitung
Gebruiksaanwijzing
Manual de instrucciones
Manual de Instruções
KI120X

Advertisement

loading
Need help?

Need help?

Do you have a question about the KI120X and is the answer not in the manual?

Questions and answers

Summary of Contents for Smeg KI120X

  • Page 1 Libretto di Istruzioni Instructions Manual Manuel d’Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções KI120X...
  • Page 2: Table Of Contents

    INDICE CONSIGLI E SUGGERIMENTI ...4 CARATTERISTICHE ...5 INSTALLAZIONE...7 USO ...11 MANUTENZIONE ...12 INDEX RECOMMENDATIONS AND SUGGESTIONS ...14 CHARACTERISTICS...15 INSTALLATION ...17 USE...21 MAINTENANCE...22 SOMMAIRE CONSEILS ET SUGGESTIONS ...24 CARACTERISTIQUES ...25 INSTALLATION ...27 UTILISATION...31 ENTRETIEN...32 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE...34 CHARAKTERISTIKEN...35 MONTAGE...37 BEDIENUNG...41 WARTUNG...42 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES ...44...
  • Page 3 ÍNDICE CONSELHOS E SUGESTÕES ...64 CARACTERÍSTICAS ...65 INSTALAÇÃO ...67 UTILIZAÇÃO...71 MANUTENÇÃO ...72...
  • Page 4: Recommendations And Suggestions

    RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation.
  • Page 5: Characteristics

    CHARACTERISTICS Dimensions 898 - 1198 Min. Min. ø 500mm 650mm...
  • Page 6: Installation

    Components Ref. Q.ty Product Components Hood Body, complete with: Controls, Light, Blower, Filters Telescopic Chimney comprising: Upper Section Lower Section Telescopic frame complete with extractor, consisting of: 7.1a Upper frame 7.1b Lower frame Right Air Outlet Grill Left Air Outlet Grill Reducer Flange ø...
  • Page 7 INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF • Use a plumb line to mark the centre of the hob on the ceiling/support shelf. • Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob.
  • Page 8 Fixing the frame • Loosen the two screws fastening the lower chimney and re- move this from the lower frame. • Loosen the two screws fastening the upper chimney and re- move this from the upper frame. If you wish to adjust the height of the frame, proceed as follows: •...
  • Page 9 RECIRCULATION VERSION AIR OUTLET • Assemble the two halves of the hood body extension piece 14 (if necessary). • Push fit the assembled hood body extension piece 14 onto the air outlet (if necessary). • Push fit connection 15 onto the hood body extension piece 14 or directly onto the hood body.
  • Page 10: Maintenance

    ELECTRICAL CONNECTION • Connect the hood to the mains through a two-pole switch hav- ing a contact gap of at least 3 mm. • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
  • Page 11 Button Function Press briefly to turn the lighting system on and off. Press and hold for approx. 2 seconds to turn the lighting system on and off at reduced intensity. Turn the suction motor on and off at speed one. If the filter saturation alarm is on, this resets it.
  • Page 12 MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned when all the command LEDs light up in a continuous manner or at least once every 2 months use, or more frequently if use is particularly intensive.
  • Page 13: Installation

    Activated Charcoal Filter (Recirculation Version) • This cannot be washed or regenerated, and must be changed when all the command LEDs start to flash, or at least once every 4 months. Activating the alarm signal • In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date.