Smeg KIV90X Instruction Manual

Smeg KIV90X Instruction Manual

Smeg ventilation hood user manual

Advertisement

Libretto di Istruzioni
Instructions Manual
Manuel d'Instructions
Bedienungsanleitung
Gebruiksaanwijzing
Manual de instrucciones
Manual de Instruções
KIV90X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KIV90X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Smeg KIV90X

  • Page 1 Libretto di Istruzioni Instructions Manual Manuel d’Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções KIV90X...
  • Page 2: Table Of Contents

    INDICE CONSIGLI E SUGGERIMENTI ...4 CARATTERISTICHE ...5 INSTALLAZIONE...7 USO ...11 MANUTENZIONE ...12 INDEX RECOMMENDATIONS AND SUGGESTIONS ...14 CHARACTERISTICS...15 INSTALLATION ...17 USE...21 MAINTENANCE...22 SOMMAIRE CONSEILS ET SUGGESTIONS ...24 CARACTERISTIQUES ...25 INSTALLATION ...27 UTILISATION...31 ENTRETIEN...32 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE...34 CHARAKTERISTIKEN...35 MONTAGE...37 BEDIENUNG...41 WARTUNG...42 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES ...44...
  • Page 3: Recommendations And Suggestions

    RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from in- correct or improper installation.
  • Page 4: Characteristics

    CHARACTERISTICS Dimensions Min. Min. 650mm 500mm...
  • Page 5: Installation

    Components Ref. Q.ty Product Components Hood Canopy complete with: Controls, Lights, Filters Telescopic chimney made up of: Upper chimney Lower chimney Telescopic frame complete with Suction fan, made up 7.1a Upper frame 7.1b Lower frame Rh Air Outlet Directional Grille Lh Air Outlet Directional Grille Reduction flange ø...
  • Page 6 INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF • Use a plumb line to mark the centre of the hob on the ceiling/support shelf. • Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob.
  • Page 7 Fixing the frame • Loosen the two screws fastening the lower chimney and re- move this from the lower frame. • Loosen the two screws fastening the upper chimney and re- move this from the upper frame. If you wish to adjust the height of the frame, proceed as follows: •...
  • Page 8: Recirculation Version Air Outlet

    RECIRCULATION VERSION AIR OUTLET • Assemble the two halves of the hood body extension piece 14 (if necessary). • Push fit the assembled hood body extension piece 14 onto the air outlet (if necessary). • Push fit connection 15 onto the hood body extension piece 14 or directly onto the hood body.
  • Page 9: Maintenance

    ELECTRICAL CONNECTION • Connect the Hood to the Mains power sup- ply, inserting a two-pole Switch with a con- tact aperture of at least 3 mm. • Remove the Metal grease filters (see par. on “Maintenance”) and make sure that the power supply Cable is properly inserted in the Suction fan socket.
  • Page 10 Button Function Press briefly to turn the lighting system on and off. Press and hold for approx. 2 seconds to turn the lighting system on and off at reduced intensity. Turn the suction motor on and off at speed one. If the filter saturation alarm is on, this resets it.
  • Page 11 MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned when all the command LEDs light up in a continuous manner or at least once every 2 months use, or more frequently if use is particularly intensive.
  • Page 12: Installation

    Activated Charcoal Filter (Recirculation Version) • This cannot be washed or regenerated, and must be changed when all the command LEDs start to flash, or at least once every 4 months. Activating the alarm signal • In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date.

Table of Contents