Mounting the hood body
• Adjust the two screws Vr, on brackets 11a, to a minimum.
• Hook the hood canopy onto the two brackets 11a.
• Remove the metal grease filters by turning the handles pro-
vided.
• From inside the hood canopy, adjust the screws Vr to set the
Hood Canopy level.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Push fit Connection 15 and Reducer Flange 9 onto the hood
body outlet.
• Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described
previously.
• Ensure that the activated charcoal filters have been inserted.
EN
Connections
Vr
ø 150
ø 120
9
15
14.1
9
1 14