Electrical Connection - Pelgrim DSG861 Series Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Electrical connection

Mounting the cooker hood
EN 12
This appliance is a Class I appliance and must be earthed.
Make sure the supply voltage ratings correspond with those stated on
the appliance data plate. The connection to the mains is carried out as
follows:
BROWN = phase L
BLUE = phase N
GREEN/YELLOW = Earth
This canopy hood has been provided with a power plug. When installing
the hood, make sure that this plug remains accessible. We recommend
installing the wall socket out of view, behind the chimney cover.
Attention:
If you want to make a fixed connection, ensure that a multi-pole switch
with a distance between contacts of 3 mm is installed in the supply
cable.
Warning! Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is
correctly assembled.
The hood is provided with a special power cable ; if the cable is
damaged, request a new one from Technical Service.
The last pages of this manual show the steps for mounting the
cooker hood.
max. 1400 mm

Advertisement

Table of Contents
loading

Table of Contents