4.5 Connection diagram

Drawing preliminary!
No.
Conn.
Designation
KL1
1
L1
KL1
2
N
PE
PE
KL2
1
NO
KL2
2
COM
KL2
3
NC
KL3
1
RSA
KL3
2
RSB
KL3
3
GND
KL3
4
Ain1 U
KL3
5
+ 10 V
KL3
6
Ain1 I
Item no. 52443-5-9970 · ENU · Change 209539 · Approved 2021-02-10 · Page 9 / 14
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Function/assignment
Supply connection, power supply; for nominal voltage range see technical data
Supply connection, power supply; for nominal voltage range see technical data
Ground connection, PE connection
Status relay, floating status contact, make for failure
Status relay, floating status contact, changeover contact, common connection, contact rating 250 VAC/max. 2
A (AC1)/min. 10 mA
Status relay, floating status contact, break for failure
Bus connection RS485, RSA, MODBUS-RTU; SELV
Bus connection RS485, RSB, MODBUS-RTU; SELV
Reference ground for control interface; SELV
Analog input 1, set value: 0-10 V, Ri = 100 kΩ, adjustable curve, only usable as alternative to input Ain1 I;
SELV
Fixed voltage output 10 VDC, + 10 V +/-3%, max. 10 mA, short-circuit-proof, power supply for ext. devices
(e.g. potentiometers); SELV
Analog input 1, set value: 4-20 mA, Ri = 100 Ω, adjustable curve, only usable as alternative to input Ain1 U;
SELV