About The Appliance; Product Description; Scope Of Delivery; Determined Use - Bosch JUNKERS Storacell PSW 500-5 Manual

Buffer cylinder
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
2

About the appliance

2.1

Product description

The buffer cylinder and thermal insulation are supplied in two units. The
thermal insulation and temperature sensors have to be installed. Each
cylinder type is available with 80 mm and 120 mm thermal insulation.
These installation and maintenance instructions apply to the following
types:
Buffer cylinder:
• PSW 500, 750-5 (special version for heat pumps)
1)
• P 500, 750, 1000-5
• P 500, 750, 1000-5 M
Buffer cylinder with connections for temperature-dependent return
feed and connection for a booster heater:
• P 500, 750, 1000-5 S
Solar buffer cylinder with connections for temperature-dependent
return feed and connections for the solar system and booster heater:
• P 500, 750, 1000-5 S-solar
Heat pump buffer cylinder with connections for temperature-dependent
return feed and connections for the solar system and booster heater:
• PSW 750, 1000-5 S-solar
The PSW 750, 1000-5 S-solar also has two laminated shims. The
laminated shims make it possible to divide the interior of the cylinder
into standby, heating and solar areas. Additionally, the flow feed lance
ensures the heat pump inflow remains stable.
H9/H11
P...S temperature-dependent return feed
H10/H12
P...S-solar/PSW...S-solar
temperature-dependent return feed
VLs/RLs
Solar system connections
E
Connection for booster heater (accessory)
Table 2 Connections (
Fig. 1, page 37)
2.2

Scope of delivery

Buffer cylinder
• Steel storage cylinder
• Technical documentation
80 mm thermal insulation
• Flexible foam thermal insulation with foil jacket
• Thermal insulation for cover
• Cylinder cover
120 mm thermal insulation
• Polyester fleece thermal insulation with PS casing, 2 parts
• Thermal insulation for cover
• Thermal insulation for base
• Cylinder cover
• Locking bracket
• Cutting compass for creating a recess in order to install a booster
heater
• Plug for thermal insulation
1) Not in Germany
PSW/P... -5 – 6 720 806 551 (2014/09)
2.3

Determined use

These buffer cylinders may only be filled with heating water and used in
sealed heating systems.
The buffer cylinders can be used for indirect potable water heating via a
freshwater station.
Only fill solar heat exchangers with propylene glycol/water mixtures
(heat transfer medium L or LS). The use of any other heat transfer
medium is not permitted.
2.4

Technical data

• Specification ( Fig. 1, page 37 and Fig. 2, page 38).
• Pressure drop diagram for solar heat exchanger ( Fig. 7, page 40).

2.4.1 Permissible maximum values

Unit
Operating pressure
bar
Heating water
Operating pressure
bar
Solar heat exchanger
Operating temperature
°C
Heating water
Operating temperature
°C
Solar heat exchanger
3
Maximum recommended
m
flow rate through
connector 1 1/2"
3
Temperature-dependent
m
feed flow rate:
3
Maximum 5 m
/h,
function successfully
tested up to:
Table 3 Permissible maximum values

2.4.2 Data plate

The data plate is located on the left, next to the connections
( Fig. 6, [2], page 40).
The data plate contains the following information:
Position Description
1
Model designation
2
Serial number
3
Actual capacity
6
Year of manufacture
9
Maximum flow temperature, heat source
10
Maximum flow temperature, solar
17
Maximum operating pressure, heat source side
18
Maximum operating pressure, solar side
Table 4 Information on the data plate
About the appliance
PSW...-5,
P...-5 S
P...-5
S-solar,
P...-5,
PSW...-5
P...-5 M
S-solar
3
3
3
10
90
90
90
130
/h
approx. 5 approx. 5 approx. 5
/h
1.5
1.5
9

Advertisement

Table of Contents
loading

Table of Contents