Average Mode Measurements (1071 Only) - Datron 1061A User Handbook Manual

Digital voltmeters
Hide thumbs Also See for 1061A:
Table of Contents

Advertisement

Average
mode
measurements
(1071 only)
Pressing
the 'Av'
key
activates
one
of
two averaging
modes:
'Continuous' or
'Block'.
With
DC
or kf2
functions
set,
selection
of
'Av'
extends
the display
to
IVi
digits
giving greater
resolution.
It
can
also
be
selected
for
other
functions,
but
without
increasing
the
display
resolution.
Interlocks
in
Averaging
Modes
Setting
'Av
deselects auto-ranging, so overscale
readings
cause
an
error indication (Error
OL).
Conversely,
setting 'Auto' deselects
'Av'.
When
'Input
Filter
is
selected
in
combination
with
'Av',
'Ratio'
or 'Remote'; the analog input
filter is
connected
in circuit,
but the high
resolution 'Rolling
Average'
mode
associated with
the
input
filter
key
is
not
selected.
Rolling,
Continuous,
and
Block Average
modes
cannot be
selected
in 'Cal'
mode.
Entry
into 'Cal'
mode
deselects
any
average
mode
set.
Choice
between
'Block
Size'
and
'Continuous'.
A
'Block'
is
a
set
of consecutive measurements,
whose
mean
value
is
calculated
and
displayed
by
the
instrument.
A
user
can
preselect
how many
measure-
ments
will
constitute a block,
by
entering
a
number
(called the
'Block
Size')
via the
front
panel keyboard.
The number
is
stored
in
an
internal
memory,
but
it
also
has
a
second
use; to
determine
which
of
the
two
averaging
modes
will
be
activated
by
pressing'
A
v':
Block
Size
=
0:
Continuous Average
Mode
Block
Size
>
1:
Block Average
Mode
When
the 1071
is
powered
on; the
block
size
is
initialized to
'O',
with
Average
OFF.
Subsequent
selection
of
'Av'
will
thus activate
'Continuous'
mode.
Access
to
Block
Size
memory.
A
user gains
access
to
the
block
size
memory
to
inspect or adjust the stored
number, by
using
the
front
panel 'Keyboard'
mode.
To
inspect the block
size:
Press
'KEYBOARD'
-
1071
enters
'Keyboard'
mode.
-
Display
=
'+0'
Press
'Av'
-
Either 'Cont'
or
a
number
appears
on
the display.
If
'Conf
is
displayed, the 1071
is
set
for
Continuous
mode.
Otherwise,
the
displayed
number
is
the
block
size
in
Block mode.
To
set
the block
size:
Press
'KEYBOARD'
-
1071 enters
'keyboard'
mode.
-
Display
=
'+0\
Enter block
size
required
-
Display
=
Value
entered
(in
range
0
to
19999)
Press
'Store'
-
Store
LED
lights
green.
Press
'Av'
-
Block
size
is
set
in
memory, and
the 1071
reverts to
its
previous
operation.
N.B.
By
entering
a
value
of
0,
Continuous
mode
is
set;
any
other value
sets
Block
mode.
3-6