Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Datron Manuals
Measuring Instruments
1061a
User handbook manual
Rear Input; A Only) Iv 2 Digits (1071 Only) - Datron 1061A User Handbook Manual
Digital voltmeters
Hide thumbs
Also See for 1061A
:
Service handbook
(202 pages)
,
Calibration and servicing handbook
(197 pages)
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
page
of
73
Go
/
73
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Rear
input
The measurement
source
may
be
connected
to
the
'REAR
I/P'
plug
instead
of the
front
panel
terminals
when
the
'I/P
SELECT
rear
panel
switch
is
set
to the
'REAR'
position.
For
all
rear
panel
inputs,
the
maximum
limit
is
250
V RMS.
When
using the
rear
panel input
plug
the front
panel
switches
'4-wire
ft
/
2-wire
ft'
and
'Local
Guard
/
Remote
Guard'
are inoperative.
Therefore
to effect
local
guarding, a connection
should
always
be
made
between
'Guard'
(pin
H)
and "Ohms
Guard'
(pin A).
For
2-wire resistance
measurement
external
connections
must
be
made
from
'Hi'
to
T+'
and
from
"Lo' to
'I—'.
Fig. 2.2
Rear
input
7
pin
plug
Thermal
EMF
Thermal
emfs
are significant
in
DC
voltage,
current
and
resistance
measurements,
especially
when
measuring low
voltages or large
currents.
These
unpredictable
thermal
emf
errors
arise
when
dissimilar
metal
junctions
are
at
different
temp-
eratures.
To
minimise thermal
emf
errors use the
same
material
throughout
the
measuring
circuit,
particularly
avoid
the use of
steel
probes,
nickel
plated terminals
and
tinned
copper
wire.
The
table
below shows thermal emfs
relative
to
hard
drawn
copper
at
23° C.
MATERIAL
EMF
gV/°C
SILVER
+0.03
GOLD
+0.01
TIN
-3
LEAD
-3
NICKEL
-22
If
dissimilar
metal
junctions
are
used ensure
that
they are
offset
by
other junctions
of the
same
material
at
the
same
temperature
and
allow
for
thermal
emfs
by making
the
measurement
twice
with
reversed
polarities.
A
lead
with gold
plated
copper
terminals
is
provided
in
the
Datron
lead
kit
for
making
low
thermal
emf
connections.
6
V
2
Digits
(1061
A
only)
7Vt
Digits
(1071
only)
terminals
(1071
:
7V2
digits)
On
the 1061
A
and
1071
models
only, selection
of
'Input
filter'
extends
the
DC
Voltage
and
Resistance
displays
by an
extra
digit:
i.e.
1061
A
is
extended
to
6
1
/2
digits.
1071
is
extended
to IVi
digits.
If
option
12
is
fitted
in 1061
A.
then
'Input
Filter'
also
selects
6
V
2
digits for
'AC
and
"DC
Coupled AC'
functions.
De-selection
of
this
feature
is
achieved by
re-pressing
the 'Input
filter'
key.
Refer
also
to
'Average
Mode
measurements'
in
Section
3.
2-9
Table of
Contents
Previous
Page
Next
Page
1
...
14
15
16
17
18
19
20
21
Advertisement
Table of Contents
Related Manuals for Datron 1061A
Multimeter Datron 1062 Service Handbook
(202 pages)
Measuring Instruments Datron 1061 Calibration And Servicing Handbook
(197 pages)
Measuring Instruments Datron 1081 User Handbook Manual
(25 pages)
Measuring Instruments Datron 1051 Servicing Manual
Digital voltmeter (129 pages)
Related Content for Datron 1061A
1081 Rear Signal Input
Datron 1081
1061 Bear Input/Ratio Input
Datron 1061
This manual is also suitable for:
1061
1071
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL