Vivitek DH976 Series User Manual page 75

Hide thumbs Also See for DH976 Series:
Table of Contents

Advertisement

RS-232C Protocol
RS232 Setting
Minimum delay for next command: 1ms
Control Command Structure
HEX
ASCII
Operation Command
Note:
"CR" mean Carriage Return
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Value(0~9999)
ASCII
VXXS0001
56h Xh Xh 53h 30h 30h 30h 31h 0Dh
VXXS0002
56h Xh Xh 53h 30h 30h 30h 32h 0Dh
VXXS0003
56h Xh Xh 53h 30h 30h 30h 33h 0Dh
VXXG0004
56h Xh Xh 47h 30h 30h 30h 34h 0Dh
VXXS0005n 56h Xh Xh 53h 30h 30h 30h 35h nh 0Dh
VXXG0005
56h Xh Xh 47h 30h 30h 30h 35h 0Dh
VXXS0006
56h Xh Xh 53h 30h 30h 30h 36h 0Dh
VXXG0007
56h Xh Xh 47h 30h 30h 30h 37h 0Dh
VXXG0008
56h Xh Xh 47h 30h 30h 30h 38h 0Dh
VXXG0009
56h Xh Xh 47h 30h 30h 30h 39h 0Dh
VXXS0009n 56h Xh Xh 53h 30h 30h 30h 39h nh 0Dh
Baud rate:
9600
Parity
None
check:
Data bit:
8
Stop bit:
1
Flow
None
Control
Header code
'V'
Command Group 00
HEX
Command code
Data code
Command
Data
Command
Data
Function
Power On
Power Off
Resync
Get Lamp Hours
Set Air filter timer
Get Air filter timer
System Reset
Get System Status
Get F/W Version
Get Alter EMail
Set Alter Email
— 66 —
A
PPENDIX
End code
0Dh
CR
Description
Return Result
P/F
P/F
P/F
Pn/F
n=0~999999
P/F
n=0~999999
Pn/F
P/F
0: Reset
1:Standby
Pn/F
2:Operation
3:Cooling
Pn/F
Pn/F
n=xxxxxx@xxxx.x
P/F
xx.xx
I