Progarmmable A/B Divider; Level Converter A/B Pulse (A/B Divider: All Off); Input/Output Mode Converter (A/B Divider: All Off) - Hohner HM210IT Manual

Level converter, direction signal decoder and programmable pulse divider
Table of Contents

Advertisement

5.

Progarmmable A/B Divider

5.1.

Level converter A/B Pulse (A/B Divider: All OFF)

If the A/B pulse have to be switched unchanged from the input to the output (no division,
no change in length and position), then the DIL switch position listed below must be
chosen. A level conversion is only possible if the input mode (A/B 90 ° or A/B dir)
corresponds to the output mode. (DIL1/6 = DIL1/7).
DIL5
(Left 8-pole)
1
2
3
4
OFF
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
5.2.

Input/Output Mode Converter (A/B Divider: All OFF)

If input mode differs from output mode and in addition, the DIL switches DIL5 and DIL6 of
the divider A/B are all set to OFF, the following signal characteristics are set up at the
output.
Case 1: Input A/B 90°, Output A/B Dir
DIL1/6 = OFF, DIL1/7 = ON with A/B Divider setting: DIL5, 6 = all OFF
If the direction of the A/B 90 ° signal changes at the input, a change takes place at the
BOUT output signal. (A/B dir). There is no division.
Case 2: Input A/B Dir, Output A/B 90°
DIL1/6 = ON, DIL1/7 = OFF with A/B Divider setting: DIL5, 6 = all OFF
If a change takes place at the BIN input signal (A/B dir), the direction of the A/B 90 ° signal
changes at the output. Here is a division 1:2, from the input in relation to the output.
Rev. 1
5
6
7
8
HM210IT User's Manual
Divider [A/B]
DIL6
(Left 3-pole)
1
2
3
Binary value
AIN = AOUT, BIN = BOUT
www.hohner.it
Comment
8