Hohner HM210IT Manual

Level converter, direction signal decoder and programmable pulse divider

Advertisement

Quick Links

Level Converter, Direction Signal Decoder and
programmable pulse divider
Product features:
• Level Converter (RS-422, HTL Single Ended, HTL Differential,
TTL and vice-versa
• Implementation between the two types of representations for the direction
of rotation (A/B 90 °, A/B Direction and vice versa)
• Adjustable division ratio of directional A / B pulses
• Adjustable division ratio for the Z pulse
• Reset of the Z divider by external input (defined setting)
• Zero setting of the A / B / Z divider by external input (defined Start / Stop)
• Z divider can also be used as an independent second divider
• Limit frequency up to 1 MHz, depending on the input format
• Push-pull outputs direct SPS control
• 9 to 30 VDC power supply
Rev. 1
HM210IT
HM210IT User's Manual
www.hohner.it
1

Advertisement

Table of Contents
loading

Summary of Contents for Hohner HM210IT

  • Page 1 • Z divider can also be used as an independent second divider • Limit frequency up to 1 MHz, depending on the input format • Push-pull outputs direct SPS control • 9 to 30 VDC power supply Rev. 1 HM210IT User’s Manual...
  • Page 2: Table Of Contents

    6.4. Independent Z Divider ................ 14 6.5. Automatic generation of a Z pulse ............15 6.6. Reset the Z divider with ZERO_Z Signal ..........15 7. Error Output ................15 8. Dimensions ................16 9. Technical Specifications ............. 17 Rev. 1 HM210IT User’s Manual...
  • Page 3: Safety Instructions And Responsibility

    Please note that device may only be installed in proper form and used in a technically perfect condition - in accordance to the “Technical Specifications” (see chapter 8). The device is not suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard. Rev. 1 HM210IT User’s Manual...
  • Page 4: Installation

    (if necessary). Unauthorized opening and repairing can have negative effects or failures to the protection-measures of the unit. Rev. 1 HM210IT User’s Manual...
  • Page 5: Introduction

    2. Introduction The HM210IT is a universal interface using with incremental measuring systems. The device allows the solution of the following problems: • Level conversion (RS-422, HTL single ended, HTL differential, TTL and vice versa) • Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 2048 •...
  • Page 6: Terminal Assignments And Connections

    A/B. Rev. 1 HM210IT User’s Manual...
  • Page 7 Z-pulse: Generation of a Z-pulse from AIN & BIN, AOUT & BOUT Z-pulse: Z input is used Test mode deactivated: OFF Output format : HTL Differential, HTL Single Ended ( – 2V) UX1(2) Output format: RS-422, TTL (5V) Rev. 1 HM210IT User’s Manual...
  • Page 8: Progarmmable A/B Divider

    If a change takes place at the BIN input signal (A/B dir), the direction of the A/B 90 ° signal changes at the output. Here is a division 1:2, from the input in relation to the output. Rev. 1 HM210IT User’s Manual...
  • Page 9: Setting The A/B Divider (At A/B Dir To A/B 90°)

    OFF OFF OFF OFF OFF OFF OFF OFF OFF ON 1 : 2050 1 : 4096 Example: Input A/B dir, output A/B 90 ° with A/B division 1:6 (setting DIL6, 5: OFF ON OFF) Division 1:2: See Input/Output Mode Conversion (A/B Divider: All OFF) Rev. 1 HM210IT User’s Manual...
  • Page 10: Setting The A/B Divider (For All Other Modes)

    Example: Input A/B 90°, output A/B 90 ° with A/B division 1:3 (setting DIL6, 5: OFF ON OFF Example: Input A/B 90°, output A/B 90 ° with A/B division 1:3 (setting DIL6, 5: OFF ON OFF Rev. 1 HM210IT User’s Manual...
  • Page 11: Setting To Zero The A/B Divider With Zero_A Signal

    5.6. Information over the signal change A/B Dir Signal changes from B (direction) should appear shortly before or latest at the same time as the A flank so that the change can be detected correctly. Rev. 1 HM210IT User’s Manual...
  • Page 12: Programmable Z Divider

    Divider [Z] DIL4 (right 8-pole) Comment Binary value Divider => 1: Binary value +1 1 : 2 1 : 3 1 : 4 1 : 253 1 : 254 1 : 255 1 : 256 Rev. 1 HM210IT User’s Manual...
  • Page 13: Location And Width Of The Z Pulse

    The pulse width at the output corresponds to the full distance between two Z pulses at the input. DIL1 Front Narrow Z pulse (1/4 output-periode) 8-pole (Only applicable to input signals A/B 90°, DIL1/6 = OFF) The pulse width at the output corresponds to ¼ period of pulse width at the input. Rev. 1 HM210IT User’s Manual...
  • Page 14: Independent Z Divider

    (additionally DIL2/1 on OFF, ZIN is used, Z divider not completely set to OFF). DIL1 Front Wide Z pulse (a full encoder turn) 8-pole The pulse width at the output corresponds to the full distance between two Z pulses at the input. Rev. 1 HM210IT User’s Manual...
  • Page 15: Automatic Generation Of A Z Pulse

    DIL3/2 refers to the line B, /B and the DIL switch DIL3/3 to the line Z, /Z. An error can only be detected in RS-422 or HTL differential format, all other formats do not trigger an error. Rev. 1 HM210IT User’s Manual...
  • Page 16: Dimensions

    Dimensions Rev. 1 HM210IT User’s Manual...
  • Page 17: Technical Specifications

    -25 °C … +70 °C / -13 … +158 °F (not condensing) Failure rate: MTBF in years: 109,3 (long-term usage at 60 °C / 140 °F ) Conformity & EMC 2004/108/EC: EN 61000-6-(2-4) standards: 2011/65/EU: RoHS Rev. 1 HM210IT User’s Manual...