1. Specifications
Holding Force
Voltage Input
Current Draw
Dimensions (Body)
** 12VDC / 24VDC is pre-set on manufacturer; once it set, it cannot be changed.
2. Basic Installation Concept & Accessories (Figure 1)
General Installation
Door
Frame
EM
Lock
Door
Out Swing
LS Bracket For
Out-Swing Door
Door
Frame
EM
Lock
Door
Out-Swing
CX-90S-03
Up to 300 Lbs.
(136 kg)
12VDC / 24VDC **
300mA / 150mA
6 11/16" W x 1 3/8" H x 13/16" D
(165 x 35 x 22 mm)
T Handle Allen Key
(Not Included)
Fixing
Screw
x2
Electromagnet
Allen Wrench
(Not Included)
12VDC / 24VDC
Power Supply
Cable Wire
Mounting Plate
Self-tapping Screw x 5
Armature
Screw
Armature Plate
Rubber
Washer
Sexnut Bolt
Metal
Guide Pin x2
Washer
Page 1 of 4
CX-90S-03
Door Magnetic Locks
Installation Instructions
U1 Bracket For
Glass Door
Door Frame
Glass
Door
Out-Swing
LZ Bracket For
In-Swing Door With Cover
Door
Frame
EM
Lock
M4 Set
Screw
Door
LZ Bracket For
In-Swing Door
Self-tapping Screw
Door
Frame
P/H MC Screw
Door
In-Swing
EM
Lock
CSK M8 x16
In-Swing
EM
Lock
M4 x 8

Advertisement

loading

Summary of Contents for CAMDEN eXact CX-90 Series

  • Page 1 CX-90S-03 Door Magnetic Locks Installation Instructions 1. Specifications CX-90S-03 Up to 300 Lbs. Holding Force (136 kg) Voltage Input 12VDC / 24VDC ** Current Draw 300mA / 150mA 6 11/16” W x 1 3/8” H x 13/16” D Dimensions (Body) (165 x 35 x 22 mm) ** 12VDC / 24VDC is pre-set on manufacturer;...
  • Page 2 CX-90S-03 Door Magnetic Locks 3. General Installation Steps & 4. Trouble Shooting Maintainance 1. Sensor not functioning: - Improper attachment of electromagnet and 1. Drill the armature plate holes in the door using the armature plate template provided. - Modification of the PCB 2.
  • Page 3 CX-90S-03 Door Magnetic Locks 6. Regular Installation Guide (Figure 2) Out Swing Door Installation Template Door Frame Template Door Door Out Swing Fold the CX-90S Template along the dotted Place the template against the door & Close the door, position the EM lock line upto 90°.
  • Page 4 CX-90S-03 Door Magnetic Locks 7. LZ Bracket for In-Swing Door Installation Guide (Figure 3) The door frame min. height value "L" is needed to accommodate the bracket Model: Door - 300LZ(L) = 39mm Frame - 600 LZ(L) = 46mm Lock - 1200LZ(L) = 73mm In Swing Door Door...

This manual is also suitable for:

Exact cx-91 seriesExact cx-90s-03Exact cx-91s-12Exact cx-91s-12tdsExact cx-91m-06Exact cx-91m-06tls ... Show all