Sony TRINITRON KV-1442 Service Manual page 14

Xe-5 chassis
Table of Contents

Advertisement

KV-1442ECPS
|
RM-651
4-2,
CONVERGENCE
Preparation:
Before starting, perform FOCUS, H.SIZE, V.SIZE
and V.LIN adjustments.
Turn
BRIGHTNESS
control fully counterclock-
wise and PICTURE control to normal.
Feed in the dot pattern.
(1) Horizontal and Vertical Static Convergence
center dot
center dot
. Adjust
H.STAT
VR
to coincide
red, green
and
blue
dots
on
the
centre
of screen
(Horizontal
movement)
. Adjust V.STAT magnet to coincide red, green and
blue dots on the centre of screen (Vertical move-
ment)
. If the red, green and blue dots do not coincide on
the centre
of screen with H.STAT
VR, perform
horizontal convergence adjustment using H.STAT
VR and V.STAT magnet as shown below. (In this
case,
H.STAT
VR
and
V.STAT
magnet
effect
each other.)
Tilt
the V.STAT
magnet
and
adjust static con-
vergence to open or close the V.STAT magnet.
QB)
®
4. When
the V.STAT
magnet
is moved in the direc-
tion of arrow
@) and (b) , Red. Green and Blue
dots move as shown below.
@_ ©@
@
©
"T
Ox-|—®
Bd
|
t
:
G
G
+
n b |
@
R
G
B
B
G eR
.
®
~ ne
RQ
BQ
XB)
G \.
G \
R
If blue dot does not
coincide
with red and
green
dots, perform following steps.
Move
BMC
magnet
(a)
to
correct
insufficient
H. static convergence.
Rotate
BMC
magnet
(b) to correct
insufficient
V. static convergence.
In either
case,
repeat
Beam
Landing
Adjustment.