Carrier 48TC 07 Installation, Start-Up And Service Instructions Manual page 58

Variable frequency drive (vfd) factory-installed option 2-speed motor control for 2-stage cooling rooftop units
Hide thumbs Also See for 48TC 07:
Table of Contents

Advertisement

40RU/40RUQ Unit VFD Parameters for Units with VFD Fan Speed Relay Board —
550/580 VFD PART
550/580 ABB PART
NUMBER
NUMBER
HK30WA353 /
ACH550-UH-017A-2 /
HK30WB305
ACH580-01-017A-2
HK30WA357 /
ACH550-UH-08A8-4 /
HK30WB321
ACH580-01-07A6-4
HK30WA361 /
ACH550-UH-06A1-6 /
HK30WB341
ACH580-01-06A1-6
HK30WA353 /
ACH550-UH-017A-2 /
HK30WB305
ACH580-01-017A-2
HK30WA357 /
ACH550-UH-08A8-4 /
HK30WB321
ACH580-01-07A6-4
HK30WA353 /
ACH550-UH-017A-2 /
HK30WB305
ACH580-01-017A-2
HK30WA357 /
ACH550-UH-08A8-4 /
HK30WB321
ACH580-01-07A6-4
HK30WA361 /
ACH550-UH-06A1-6 /
HK30WB341
ACH580-01-06A1-6
HK30WA354 /
ACH550-UH-024A-2 /
HK30WB306
ACH580-01-024A-2
HK30WA358 /
ACH550-UH-012A-4 /
HK30WB322
ACH580-01-012A-4
HK30WA362 /
ACH550-UH-09A0-6 /
HK30WB342
ACH580-01-09A0-6
HK30WA354 /
ACH550-UH-024A-2 /
HK30WB306
ACH580-01-024A-2
HK30WA358 /
ACH550-UH-012A-4 /
HK30WB322
ACH580-01-012A-4
HK30WA362 /
ACH550-UH-09A0-6 /
HK30WB342
ACH580-01-09A0-6
HK30WA355 /
ACH550-UH-031A-2 /
HK30WB307
ACH580-01-031A-2
HK30WA359 /
ACH550-UH-015A-4 /
HK30WB324
ACH580-01-023A-4
HK30WA363 /
ACH550-UH-011A-6 /
HK30WB343
ACH580-01-011A-6
Table 29 — ACH550/580 VFD Parameters —
40RUA 07-30, 40RUS 08-30 and 40RUQ 07-25 (cont)
550 / 580
550 / 580
MAX
MIN
AMPS
FREQ
2003 /
2007 /
30.17
30.13
9.1
0 Hz
4.6
0 Hz
3.9
0 Hz
10.6
0 Hz
5.3
0 Hz
12.9
0 Hz
6.4
0 Hz
4.8
0 Hz
17.6
0 Hz
7.4
0 Hz
6.2
0 Hz
25.8
0 Hz
11.2
0 Hz
10.4
0 Hz
35.4
0 Hz
17.7
0 Hz
12.7
0 Hz
550 / 580
550 / 580
550 / 580
MAX
SWITCH
START
FREQ
FREQ
FCN
2008 /
2606 /
2101 /
30.14
97.01
21.19
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
60 Hz
4 kHz
Auto
58
550 / 580
550 / 580
550 / 580
STOP
ACCEL/
ACCEL
FCN
DECEL
2202 /
2102 /
2201 /
28.72
21.03
28.71
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
Ramp
Not Sel / 0
30 sec
550 / 580
DECEL
2203 /
28.73
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec
30 sec

Advertisement

Table of Contents
loading

Table of Contents