PoE considerations
The PoE and PoE+ power supplied by the switch is prioritized in ascending port order
(from port 1 to port 4), with a total power budget of 83W for the GS305PPv3. If the power
requirements for the attached powered devices (PDs) exceed the total power budget of
the switch, the PD on the highest-numbered port is disabled to make sure that the PDs
that are connected to the higher-priority, lower-numbered ports are supported first.
PoE troubleshooting
Here are some tips for correcting PoE problems that might occur:
If the PoE Max LED is yellow, disconnect one or more PoE devices to prevent PoE
oversubscription. Start by disconnecting the device from the highest-numbered port.
For each powered device (PD) that is connected to the switch, the associated right
port LED on the switch lights solid green. If the right port LED lights yellow, a PoE fault
occurred because of one of the conditions listed in the following table.
PoE Fault Condition
Possible Solution
A PoE-related short circuit occurred on the port.
The problem is most likely with
the attached PD. Check the
The PoE power demand of the PD exceeded
condition of the PD, or restart
the maximum level that the switch permits. The
the PD by disconnecting and
maximum level is 15.4W for a PoE connection or
reconnecting the PD.
30W for a PoE+ connection
The PoE current on the port exceeded the
classification limit of the PD.
The PoE voltage of the port is outside the range
Power cycle the switch to see if
that the switch permits
the condition resolves itself.
© NETGEAR, Inc., NETGEAR and the NETGEAR Logo
are trademarks of NETGEAR, Inc. Any non‑NETGEAR
trademarks are used for reference purposes only.
August 2022
Mount the switch on a wall
We recommend that you use the wall-mount screws that came with the switch.
1.
Locate the two mounting holes on the bottom panel of the switch.
2.
Mark and drill two mounting holes in the wall.
3.
The two mounting holes must be 3.19 in. (80 mm) apart, center-to-center. Insert the
supplied anchors into the wall and tighten the screws with a No. 2 Phillips screwdriver.
Leave about 0.125 in. (4 mm) of each screw protruding from the wall so that you can
insert the screw heads into the holes on the bottom panel.
NOTE: The screws are 3 mm in diameter, 25 mm in length.
Specifications
Specification
Description
Network interface
RJ-45 connector for 1000BASE-T, 100BASE-TX, or 10BASE-T
Network cable
Category 5 (Cat 5) or higher rated Ethernet cable
Ports
5 total. Ports 1-4 can provide PoE+; Port 5 is an uplink port.
Power adapter
54V @ 1.66A DC input
Power consumption
90W maximum; 1.01W standby
PoE power budget
30W maximum per PoE+ port with a total PoE power budget
of 83W for the switch
Dimensions (W x D x H)
6.2 x 4.0 x 1.1 in. (158 x 101 x 27 mm)
Weight
0.88 lb (0.40 kg)
Operating temperature
32–104°F (0–40°C)
Operating humidity
10%–90% relative humidity, noncondensing
Support and Community
Visit netgear.com/support to get your questions answered and access the latest
downloads.
You can also check out our NETGEAR Community for helpful advice at community.
netgear.com.
Regulatory and Legal
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en français
canadien à https://www.netgear.com/support/download/.
(If this product is sold in Canada, you can access this document in Canadian French at
https://www.netgear.com/support/download/.)
For regulatory compliance information including the EU Declaration of Conformity, visit
https://www.netgear.com/about/regulatory/.
See the regulatory compliance document before connecting the power supply.
For NETGEAR's Privacy Policy, visit https://www.netgear.com/about/privacy-policy.
By using this device, you are agreeing to NETGEAR's Terms and Conditions at
https://www.netgear.com/about/terms-and-conditions. If you do not agree, return the
device to your place of purchase within your return period.
Do not use this device outdoors. The PoE source is intended for intra building connection
only.
Applicable to 6 GHz devices only: Only use the device indoors. The operation of 6 GHz
devices is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation
of this device is permitted in large aircraft while flying above 10,000 feet. Operation of
transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications
with unmanned aircraft systems.
NETGEAR, Inc.
NETGEAR INTERNATIONAL LTD
Floor 1, Building 3,
350 East Plumeria Drive
San Jose, CA 95134, USA
University Technology Centre
Curraheen Road, Cork,
T12EF21, Ireland

Advertisement

loading