Table 7: Battery Calculation Form
Ref. No.
Submitted By:
Project Name:
Project Location:
Panel Location:
Node No:
Module
Description
FCM2018-U3
Operating Unit
Operating Unit
FCM2019-U3
(+ LED)
FCI2016-U1
Periphery board (250p)
FCI2017-U1
Periphery board (500p)
FCI2011-U1
NAC module (1A/2B)
XCI2001-U1
Releasing module
FCI2020-U1
Leased line/city tie mod.
FN2001-A1
Network module (SAFEDLINK)
FCA2016-U1
RS485 class A module (iso.)
FN2006-U1
Fiber network module (SM)
FN2007-U1
Fiber network module (MM)
FT2014-xx
Remote display (color)
FT2015-xx
Remote terminal (key, color)
FTI2001-U1
Fire Terminal Board
FCM2023-U3
Option module (LED)
FCA2015-U1
Dialer module (DACT)
FCA2018-U1
Remote peripheral module
FT2003-U1
Graphic driver (I/O)
FCA2032-U1
Battery disconnect module
VCA2002-A1
Card Cage
VCC2002-A1
Voice I/O module
VCC2001-A1
Voice CPU card
VCI2001-U1
Voice ampl. Card (25V/70V)
VN2001-A1
Ethernet module (electric)
24
Siemens Industry, Inc.
Smart Infrastructure
Date:
Module
Feature
Qty
LED zones
SLC load
2
NAC load
Aux power
1
load
Bell Follower
No
SLC load
2
NAC load
Aux power
1
load
Bell Follower
No
No
0
2
NAC load
No
0
Releasing
2
load
Not Installed
LED zones
Enter
value
Select choice
Fixed
Calculated
Standby
Alarm
Current
Current
Comments
0.000
0.000
125 mA (standby), 166 mA (alarm) per module
0.000
0.000
130 mA (standby), 170 mA (alarm) per module
1 mA per zone (3 LEDs per zone)
110 mA (standby), 136 mA (alarm)
0.000
0.000
Calculated device load from below
NAC alarm current from signals
External Aux power for standby & alarm
0.000
0.000
4mA if Bell Follower is active
120 mA (standby), 136 mA (alarm)
0.000
0.000
Calculated device load from below
NAC alarm current from signals
0.000
0.000
External Aux power for standby & alarm
0.000
0.000
4mA if Bell Follower is active
0.000
0.000
15 mA (standby), 40 mA (alarm)
NAC alarm current from signals
11 mA (standby), 40 mA (alarm) per module, 1
0.000
0.000
mA per releasing circuit
Releasing alarm current from solenoids
27 mA (standby), 40 mA (alarm) for LL;
0.000
0.000
2 mA (standby) 13 mA (alarm) for City Tie
0.000
0.000
35 mA per module
0.000
0.000
58 mA per module
0.000
0.000
127 mA per module
0.000
0.000
132 mA per module
0.000
0.000
34 mA (standby) 55 mA (alarm) per module
0.000
0.000
34 mA (standby) 55 mA (alarm) per module
0.000
0.000
11 mA per module
0.000
0.000
5 mA per module
0.000
0.000
1 mA per zone (3 LEDs per zone)
0.000
0.000
25 mA (standby), 33 mA (alarm) per module
0.000
0.000
73 mA per module
0.000
0.000
19.5 mA (standby) 32 mA (alarm) per module
0.000
0.000
7 mA (standby) 12.6 mA (alarm) per module
0.000
0.000
4 mA (standby) 4 mA (alarm)
0.000
0.000
151 mA (standby) 156 mA (alarm) per module
0.000
0.000
200 mA (stanby) 210mA(alarm) per module
196 mA(standby) 2.42A @ 25V (alarm) per
0.000
0.000
module
0.000
0.000
7 mA(standby) 7mA (active) per module
A6V10356958_en--_n