Rigol RSA5065-TG User Manual
Rigol RSA5065-TG User Manual

Rigol RSA5065-TG User Manual

Real-time spectrum analyzer
Hide thumbs Also See for RSA5065-TG:
Table of Contents

Advertisement

Quick Links

User Guide
RSA5000 Series Real-time
Spectrum Analyzer
Sept. 30, 2018
RIGOL TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Rigol RSA5065-TG

  • Page 1 User Guide RSA5000 Series Real-time Spectrum Analyzer Sept. 30, 2018 RIGOL TECHNOLOGIES CO., LTD.
  • Page 3 Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. ⚫ RIGOL reserves the right to modify or change parts of or all the specifications ⚫ and pricing policies at the company’s sole decision. Information in this publication replaces all previously released materials.
  • Page 4: Safety Requirement

    RIGOL Safety Requirement General Safety Summary Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injury or damage to the instrument and any product connected to it. To prevent potential hazards, please follow the instructions specified in this manual to use the instrument properly.
  • Page 5 Do Not Operate with Suspected Failures. If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized personnel before further operations. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
  • Page 6: Safety Notices And Symbols

    RIGOL Safety Notices and Symbols Safety Notices in this Manual: WARNING Indicates a potentially hazardous situation or practice which, if not avoided, will result in serious injury or death. CAUTION Indicates a potentially hazardous situation or practice which, if not avoided, could result in damage to the product or loss of important data.
  • Page 7: Care And Cleaning

    RIGOL Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Cleaning Clean the instrument regularly according to its operating conditions. Disconnect the instrument from all power sources.
  • Page 8: Rsa5000 Series Overview

    RIGOL RSA5000 Series Overview RSA5000 series is a new generation of cost-efficient real-time spectrum analyzer with high performance. With superb performance specifications and the clear user interface, the RSA5000 series allows you to operate it through various ways, such as pressing keys on the front panel, using the touch screen, connecting the mouse and the keyboard.
  • Page 9: Document Overview

    RIGOL Document Overview Topics in this manual: Chapter 1 Quick Start This chapter introduces the front/rear panel and user interface as well as announcements during first use of the analyzer. Chapter 2 Functions of the Front Panel of GPSA This chapter gives detailed function descriptions of the GPSA's front panel keys and the associated menu keys.
  • Page 10 FREQ on the front panel and then pressing the menu softkey Center Freq. Content Conventions in this Manual: The RSA5000 series spectrum analyzer includes the following models. This manual takes RSA5065-TG as an example. Model Frequency Range Tracking Generator RSA5065 9 kHz to 6.5 GHz...
  • Page 11: Table Of Contents

    Contents RIGOL Contents Guaranty and Declaration ................. I Safety Requirement ................II General Safety Summary ................II Safety Notices and Symbols ..............IV Care and Cleaning ..................V Environmental Considerations ..............V RSA5000 Series Overview ..............VI Document Overview ................VII Chapter 1 Quick Start .................
  • Page 12 Contents RIGOL AMPT ..................... 2-9 Sweep and Function Settings..............2-14 BW ....................2-14 Sweep ..................2-18 Trigger ..................2-22 Trace .................... 2-26 Tracking Generator (Option) ............2-32 Measurement Settings ................2-35 Meas .................... 2-35 Meas Setup ................... 2-38 Marker Measurement ................2-66 Marker ..................
  • Page 13 Contents RIGOL Recall ................... 6-13 Save ..................... 6-15 Chapter 7 Remote Control ..............7-1 Remote Control Overview ............... 7-2 Remote Control via USB ................. 7-3 Remote Control via LAN ................. 7-4 Chapter 8 Troubleshooting ..............8-1 Chapter 9 Appendix ................9-1 Appendix A: RSA5000 Accessories and Option List ........
  • Page 15: Chapter 1 Quick Start

    Chapter 1 Quick Start RIGOL Chapter 1 Quick Start This chapter gives you a quick review about the appearance and dimensions of the RSA5000 series, its front and rear panel, user interface, as well as announcements during first use of the analyzer.
  • Page 16: General Inspection

    The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
  • Page 17: Appearance And Dimensions

    Chapter 1 Quick Start RIGOL Appearance and Dimensions Figure 1-1 Front View Unit: mm Figure 1-2 Vertical View Unit: mm RSA5000 User Guide...
  • Page 18: To Prepare For Use

    Chapter 1 Quick Start RIGOL To Prepare for Use To Adjust the Supporting Legs You can unfold the supporting legs to use them as stands to tilt the instrument upwards for easier operation and observation. You can also fold the supporting legs for easier storage or shipment when the instrument is not in use.
  • Page 19: To Connect To Ac Power

    Chapter 1 Quick Start RIGOL To Connect to AC Power Please use the power cord provided in the accessories to connect the spectrum analyzer to the AC power source. The AC power supply specification of this spectrum analyzer is 100-240 V, 45-440 Hz. The power consumption of the instrument cannot exceed 95 W.
  • Page 20: To Set The System Language

    Chapter 1 Quick Start RIGOL To Set the System Language RSA5000 series spectrum analyzer supports multiple system languages. You can press System → Language to switch the system language. RSA5000 User Guide...
  • Page 21: Front Panel

    Back to previous menu item Utility function key area Function key area Page up/down key Help key Speaker Knob Earphone jack Arrow keys USB HOST RF input Power key Note : This function is only available for RSA5065-TG/RSA5032-TG. RSA5000 User Guide...
  • Page 22: Function Keys On The Front Panel

    Chapter 1 Quick Start RIGOL Function Keys on the Front Panel Figure 1-5 Function Keys Table 1-2 Descriptions of Function Keys on the Front Panel Function Key Description Sets the parameters such as center frequency, start frequency, and stop frequency; enables the signal tracking function.
  • Page 23 Recalls the files. Manages the files. Saves the files. User-defined shortcut key. Provides quick save function. Note : This function is only available for RSA5065-TG/RSA5032-TG. Note : This function is only available for the instrument installed with RSA5000-AMK. RSA5000 User Guide...
  • Page 24: Utility Function Keys On The Front Panel

    Chapter 1 Quick Start RIGOL Tip: Click the function keypad icon at the right corner of the LCD or finger-touch it, and then the function keypad that corresponds to the specified keys on the front panel appears. At this time, you can operate the instrument with the function keypad.
  • Page 25: Front Panel Key Backlight

    Chapter 1 Quick Start RIGOL Front Panel Key Backlight The on/off state and the color of the backlights of some keys on the front panel indicate the working state of the spectrum analyzer. The states are listed below. 1. Power Key Flash on and off alternatively, in breathing state: indicates that the unit is in ⚫...
  • Page 26: Front Panel Connector

    Chapter 1 Quick Start RIGOL Front Panel Connector USB HOST Earphone Jack RF Input TG Output Figure 1-6 Front Panel Connector 1. USB HOST The analyzer can serve as a "master" device to connect to the external USB device. The USB storage device, mouse, and keyboard can be connected to the instrument via the interface.
  • Page 27 3. Gen Output 50Ω The output of the tracking generator can be connected to a receiver through a cable with an N male connector. This function is only available for RSA5065-TG/RSA5032-TG. CAUTION To avoid damage to the tracking generator, the reverse power cannot exceed +10 dBm when the frequency is lower than 10 MHz;...
  • Page 28: To Use The Numeric Keypad

    Chapter 1 Quick Start RIGOL To Use the Numeric Keypad The numeric keypad is available on the front panel of RSA5000, as shown in the figure below. The numeric keypad supports the Chinese characters, English uppercase/lowercase letters, numbers, and common symbols (including decimal point, space, and +/- signs), which are mainly used to edit the file/folder name and set parameters (refer to "Parameter Setting").
  • Page 29 Chapter 1 Quick Start RIGOL The number input mode is, by default, selected for parameter setting. Press ⚫ this key to input the symbol ("+" or "-"). When you press the key for the first time, the parameter symbol "-" is displayed, and when you press it again, "+"...
  • Page 30: Rear Panel

    Chapter 1 Quick Start RIGOL Rear Panel The rear panel of RSA5000 is shown in the following figure. Figure 1-8 Rear Panel 1. AC Power Cord Connector The AC power supply specification of RSA5000 is: 100-240 V; 45-440 Hz. 2. Fuse Holder You can replace the fuse.
  • Page 31 Chapter 1 Quick Start RIGOL reference is lost, transfinite, or not connected, the instrument switches to the internal reference automatically. At this time, the icon "Ext" in the status bar of the user interface disappears. The [10MHz IN] and [10MHz OUT] connectors are usually used to ⚫...
  • Page 32: User Interface

    Chapter 1 Quick Start RIGOL 13. IF OUT Indicates the intermediate frequency signal in the output RF component. Its center frequency is 430 MHz. User Interface 6 7 8 10 11 12 13 14 24 23 22 21 20 17 16...
  • Page 33 Chapter 1 Quick Start RIGOL Trace indicator Displays information about the trace and the detector. Information setting : indicates messages, such as the prompt messages, alarm messages, and error messages. : indicates the speaker. You can tune it up and...
  • Page 34: Mouse/Keyboard/Touch Screen Operation Rule

    Chapter 1 Quick Start RIGOL frequency and stop frequency. Y scale Indicates the scale indication in the Y axis. Note : The display of the trace indicator is shown in the following figure: Trace Number Trace Type Detector Type ⚫ The first line displays the trace number. The color of the number is the same as that of the trace.
  • Page 35: Keyboard Operation Rule

    Chapter 1 Quick Start RIGOL Keyboard Operation Rule Connect the keyboard to the spectrum analyzer via the USB HOST interface, and then use the shortcut keys on the keyboard to perform the same function as what you do with the front panel keys.
  • Page 36: Touch Screen Operation Rule

    Chapter 1 Quick Start RIGOL numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0) and a decimal point(.) Back Backspace Enter Enter Arrow keys ↑, ↓, ←, → (Up/Down/Left/Right arrow key) 7 menu softkeys from top to F1 to F7...
  • Page 37: Menu Operation

    Chapter 1 Quick Start RIGOL Menu Operation There are 6 types of menus according to their operation modes. Each type of menu and its operation method are introduced below. 1. Parameter Input Select the menu and use the numeric keys to modify the value directly.
  • Page 38 Chapter 1 Quick Start RIGOL Tip: The above menu operations can be executed by touch gestures or clicking with the externally connected mouse. Also, you can connect to the keyboard and use the shortcut keys to perform the above menu operations. For the matching relations between the front panel keys and the keyboard shortcut keys, refer to Table 1-5.
  • Page 39: Parameter Setting

    Chapter 1 Quick Start RIGOL Parameter Setting You can enter the desired parameter values by using the numeric keys, the knob, or arrow keys on the front panel. Also, you can set the parameters by using the touch screen, the externally connected keypad or the mouse. This section takes an example (set the center frequency to 800 MHz) to describe six methods of parameter setting.
  • Page 40 Chapter 1 Quick Start RIGOL Then the numeric keypad is displayed. Input 800, and select the desired unit "MHz". 5. Use the keyboard Press "Shift + f" to open the Frequency menu; Press "F1" to select Center Freq; Input 800 by using the numeric keys;...
  • Page 41: To Use The Built-In Help System

    Chapter 1 Quick Start RIGOL To Use the Built-in Help System The built-in help system provides information about every function key on the front panel and every menu softkey. 1. Get the built-in help information Press Help and a prompt message about how to obtain help information will be shown on the screen.
  • Page 42: Fuse Replacement

    Chapter 1 Quick Start RIGOL Fuse Replacement If you need to replace the fuse, use only the specified fuse (AC 250V, T3.15A) and perform the following operations: 1. Turn off the instrument, cut off the power, and remove the power cord.
  • Page 43: Mode Setting

    Chapter 1 Quick Start RIGOL Mode Setting Mode Provides two working modes: GPSA (general purpose spectrum analyzer) and RTSA (real-time spectrum analyzer). Note: In different working modes, the functions of the keys on the front panel may be different. Press Help to display the help information of the current working mode.
  • Page 44: Mode Setup

    Chapter 1 Quick Start RIGOL Mode Setup The Mode Setup menu is used to set parameters global to different measurements under all working modes. These parameters are independent of the currently running measurement, and they are global to all the measurements.
  • Page 45: Chapter 2 Functions Of The Front Panel Of Gpsa

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Chapter 2 Functions of the Front Panel of GPSA This chapter describes in detail the function keys on the front panel and their associated menu functions. Contents in this chapter: Basic Settings ◼...
  • Page 46: Basic Settings

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Basic Settings FREQ Sets the frequency parameters of the analyzer. The analyzer sweeps within a specified frequency range and restarts sweeping every time the frequency parameters are modified. The frequency range of a channel can be expressed by either of two groups of parameters: Start Frequency/Stop Frequency ( );...
  • Page 47 Chapter 2 Functions of the Front Panel of GPSA RIGOL Center Freq Sets the center frequency (that corresponds to the horizontal center of the graticule) of the current channel. Press this key or touch the specified menu item on the screen to set the frequency entry mode to Center Frequency/Span.
  • Page 48 Chapter 2 Functions of the Front Panel of GPSA RIGOL Start Freq Sets the start frequency of the current frequency channel. Press this key or touch the specified menu item on the screen to set the frequency entry mode to Start Frequency/Stop Frequency.
  • Page 49 Chapter 2 Functions of the Front Panel of GPSA RIGOL refer to descriptions in "Parameter Setting". Table 2-3 Stop Frequency Parameter Remarks Default center frequency+span/2 Range 0 Hz to Fmax Unit GHz, MHz, kHz, Hz Knob Step span > 0, step = span/200...
  • Page 50 Chapter 2 Functions of the Front Panel of GPSA RIGOL CF Step Mode The CF step mode consists of "Manual" and "Auto". Remarks: In Auto mode, the CF step is 1/10 of the span in non-zero span mode or equals ⚫...
  • Page 51 Chapter 2 Functions of the Front Panel of GPSA RIGOL Start Execute a sweep Active Marker exists? Search for and mark the Search for frequency point (variation peak and < 3dB) near the Marker mark it as Marker Set marker...
  • Page 52: Span

    Chapter 2 Functions of the Front Panel of GPSA RIGOL SPAN Sets the span of the analyzer. Changing this parameter will change the frequency parameters, and after the span is changed, the sweep restarts. Span Sets the frequency range of the current channel. Press this key or touch the specified menu item on the screen to set the frequency entry mode to Center Frequency/Span.
  • Page 53: Ampt

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Full Span Sets the maximum span. Zero Span Sets the span to 0 Hz. The values of start frequency and stop frequency are the same as that of the center frequency. The X-axis is time. The analyzer measures the time-domain characteristics of the amplitude at the center frequency point of the input signal.
  • Page 54 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-7 Reference Level Parameter Remarks Default 0 dBm Range -170 dBm to 30 dBm Unit dBm, -dBm, V, mV, uV Knob Step In Log scale mode, step = scale/10 In Lin scale mode, step = 0.1 dBm...
  • Page 55 Chapter 2 Functions of the Front Panel of GPSA RIGOL Atten Auto Selects "Manual" or "Auto" to be the current attenuation mode. Remarks: To select "Manual" to be the attenuation mode, press Attenuation to set the ⚫ attenuation value, and the attenuation mode will be automatically switched to "Manual".
  • Page 56 Chapter 2 Functions of the Front Panel of GPSA RIGOL Scale Type Sets the scale type of the Y-axis to Lin or Log. By default, it is Log. Remarks: In Log scale type, the Y-axis denotes the logarithmic coordinate. The top line of ⚫...
  • Page 57 Chapter 2 Functions of the Front Panel of GPSA RIGOL Max Mixer Lvl Sets the maximum input level of the mixer according to the amplitude of the signal. Remarks: For the high-level input signal, select a smaller maximum mixer level to increase ⚫...
  • Page 58: Sweep And Function Settings

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Sweep and Function Settings Sets the parameters such as RBW (Resolution Bandwidth) and VBW (Video Bandwidth). Sets the resolution bandwidth (RBW) to distinguish two signals whose frequencies are close with each other.
  • Page 59 Chapter 2 Functions of the Front Panel of GPSA RIGOL SPAN/RBW Ratio Sets the ratio of span to RBW. You can use the numeric keys, the knob, and the arrow keys on the front panel to modify this parameter; also you can modify it on the touchscreen.
  • Page 60 Chapter 2 Functions of the Front Panel of GPSA RIGOL Sets the video bandwidth (VBW) to filter out the noises outside the video band. Remarks: Reducing VBW makes the spectral line smoother, so that the low-level signal in ⚫ the noise can be detected, but this will also prolong the sweep time (when sweep time is set to Auto, it will be affected by both RBW and VBW).
  • Page 61 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-15 VBW/RBW Ratio Parameter Remarks Default Range 0.00001 to 3,000,000 Unit None Knob Step at 1-3-10 step Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-3-10 step VBW/RBW Mode Sets the coupling mode of the VBW/RBW ratio.
  • Page 62: Sweep

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Sweep Sets sweep-related parameters, such as sweep time, sweep points, and sweep mode. Sweep Points Sets the number of points acquired in each sweep, i.g. the number of the trace points.
  • Page 63 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-17 Sweep Time Parameter Remarks Default 1 ms Range 1 μs to 6,000 s Unit s, ms, μs, ns, ps Knob Step sweep time/100, Min = 1 μs Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-1.5-2-3-5-7.5 step...
  • Page 64 Chapter 2 Functions of the Front Panel of GPSA RIGOL enabled, press this key to enter continuous sweep mode. In this case, if the trigger conditions are met, the instrument will sweep continuously. In continuous sweep mode, the system will send a trigger initialization signal ⚫...
  • Page 65 Chapter 2 Functions of the Front Panel of GPSA RIGOL ":INIT" command through the remote interface) should be executed before judging the trigger conditions. Press “Single” Measurement status? Single sweep mode? Single sweep mode? Enter single sweep mode Enter single sweep/...
  • Page 66: Trigger

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Trigger Selects the trigger source and sets trigger-related parameters. Trigger Source Sets "Free Run", "External 1", "External 2", or "Video" to be the trigger source. 1. Free Run The trigger conditions are met at any time, that is, the analyzer generates trigger signals continuously.
  • Page 67 Chapter 2 Functions of the Front Panel of GPSA RIGOL Trig Delay Sets the time interval during which the instrument waits to start the sweep operation after the trigger signal that meets the trigger conditions is generated. You can use the numeric keys, the knob, and the arrow keys on the front panel to modify this parameter;...
  • Page 68 Chapter 2 Functions of the Front Panel of GPSA RIGOL Trigger Holdoff Sets the holdoff time between trigger signals. You can use the numeric keys, the knob, and the arrow keys on the front panel to modify this parameter; also you can modify it on the touchscreen.
  • Page 69 Chapter 2 Functions of the Front Panel of GPSA RIGOL triggers on the rising edge … … trigger s ignal … … sweep measurement1 trigger delay aut o trig trigger delay trigger occurs trigger occurs … … sweep measu rement2...
  • Page 70: Trace

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Trace Displays the sweep signal on the screen. Press Trace to set parameters for trace. Trace Selection RSA5000 can display at most 6 traces synchronously. Each trace is indicated in different colors (Trace1-yellow, Trace2-dark blue, Trace3-green, Trace4-purple, Trace5-light blue, Trace6-orange).
  • Page 71 Chapter 2 Functions of the Front Panel of GPSA RIGOL Detector Type Sets the detector for the current measurement. The selected detector can be applied to the selected trace. The available trace detectors include Pos Peak, Neg Peak, Normal, Sample, Average (RMS), and Average (Vol).
  • Page 72 Chapter 2 Functions of the Front Panel of GPSA RIGOL   (2-9) Wherein, is the average of voltage in V; is the number of sampled values for each point displayed; and is the envelop of the sampled value in V.
  • Page 73 Chapter 2 Functions of the Front Panel of GPSA RIGOL ➢ Load the stored data to trace. ➢ Trace data are cleared by the trace clear function. When inactive trace is displayed, the trace will not be zoomed in or out based on ⚫...
  • Page 74 Chapter 2 Functions of the Front Panel of GPSA RIGOL (2-13) − Trace Offset result In the above formula, the parameter unit is dB. 5. Op1–Op2+Ref Operand 1 (Op1) minus Operand 2 (Op2), and then plus the reference (Reference). Then, saves the result to the destination trace. During the sweep,...
  • Page 75 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-22 Offset Parameter Remarks Default 0 dB Range -100 dB to 100 dB Unit Knob Step 1 dB Left/Right Arrow Key Step Up/Down Arrow Key Step 10 dB Reference Sets the log reference difference in the math operation function.
  • Page 76: Tracking Generator (Option)

    RIGOL Tracking Generator (Option) Sets the parameter related to the tracking generator (TG). This function is only available for RSA5065-TG/RSA5032-TG. Tracking Generator Enables or disables the tracking generator. When the tracking generator is enabled, a signal with the same frequency as that of the current sweep signal will be output from the [GEN OUTPUT 50Ω] connector on...
  • Page 77 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-25 Tracking Generator Output Amplitude Offset Parameter Remarks Default 0 dB Range -200 dB to 200 dB Unit Knob Step 1 dB Left/Right Arrow Key Step Up/Down Arrow Key Step...
  • Page 78 Chapter 2 Functions of the Front Panel of GPSA RIGOL 3. Reference Position After the normalize function is enabled, you can adjust the vertical position of Reference Level on the screen by adjusting the reference position. The function of this menu is similar to that of Reference Level. When it is set ⚫...
  • Page 79: Measurement Settings

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Measurement Settings Meas Provides swept SA and VSWR, as well as multiple advanced measurement functions, including time-domain power, adjacent channel power, multi-channel power, occupied bandwidth, emission bandwidth, C/N ratio, harmonics, and TOI.
  • Page 80 Chapter 2 Functions of the Front Panel of GPSA RIGOL resolution bandwidth of the analyzer will be adjusted to smaller values automatically. Select Multichan Pwr and then press Meas Setup to set the corresponding parameters. 5. Occupied BW Integrates the power within the whole span and then calculates the bandwidth occupied by this power according to the specified power ratio.
  • Page 81 Chapter 2 Functions of the Front Panel of GPSA RIGOL VSWR Enables or disables the VSWR measurement function. When the VSWR measurement function is enabled, the user interface is divided into two sections automatically (the lower section provides the measurement wizard). At this time, you can perform the VSWR measurement according to the wizard.
  • Page 82: Meas Setup

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Meas Setup Open the parameter setting menu of the function selected in the Meas menu. Swept SA 1. Avg Number Specifies the number of counts (N) for Average, Max Hold, and Min Hold. For Average, the greater the value of N, the smoother the trace is displayed.
  • Page 83 Chapter 2 Functions of the Front Panel of GPSA RIGOL OldAvg Newdata −  ( ) (2-17) NewAvg 20log In the above formula, the parameter unit is dB. 3. Avg State Enables or disables the auto average function. When the auto average function is enabled, the instrument will select the best average type based on the current settings.
  • Page 84 Chapter 2 Functions of the Front Panel of GPSA RIGOL current editing point changes along with the center frequency. Y To Ref: When "Fixed" is selected, the amplitude of the current ⚫ editing point will not be affected by the reference level. When "Relative"...
  • Page 85 Chapter 2 Functions of the Front Panel of GPSA RIGOL 7) Deletes All Limits Deletes all limit lines. After you press the menu, the data of all the limit lines will be cleared and they will be restored to factory defaults.
  • Page 86 Chapter 2 Functions of the Front Panel of GPSA RIGOL Time-domain Power (T-Power) Measurement Interface: Start Line Stop Line Measurement Result Measurement Parameters Figure 2-5 T-Power Measurement Interface Measurement Result: T-power, i.g. the power of the signal from the start line to stop line.
  • Page 87 Chapter 2 Functions of the Front Panel of GPSA RIGOL 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is selected, the result is the exponential average of the ⚫...
  • Page 88 Chapter 2 Functions of the Front Panel of GPSA RIGOL You can use the numeric keys, the knob, or arrow keys to modify this parameter; you can also use the touch screen to modify the parameter. Table 2-31 Stop Line for T-Power Measurement...
  • Page 89 Chapter 2 Functions of the Front Panel of GPSA RIGOL Measurement Interface: Main Channel Bandwidth Channel Spacing Adjacent Channel Bandwidth Figure 2-6 Adjacent Channel Power Measurement Interface Measurement Results: main channel power, upper-adjacent channel power, and lower-adjacent channel power. Main channel power: displays the power within the bandwidth of the main ⚫...
  • Page 90 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-32 Average Count of ACP Measurement Parameter Remarks Default Range 1 to 1,000 Unit None Knob Step Left/Right Arrow Key Step Up/Down Arrow Key Step 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average type is "Exponential".
  • Page 91 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-34 Adjacent Channel Bandwidth for ACP Measurement Parameter Remarks Default 2 MHz Range 33 Hz to 2.5 GHz Unit GHz, MHz, kHz, Hz Knob Step adjacent channel bandwidth/100, Left/Right Arrow Key Step...
  • Page 92 Chapter 2 Functions of the Front Panel of GPSA RIGOL Multichan Pwr Measurement Interface: Channel Span Channel Span Channel Span Span Figure 2-7 Multi-channel Power Measurement Interface Measurement Results: channel power and power spectral density Channel Power: power within the channel span.
  • Page 93 Chapter 2 Functions of the Front Panel of GPSA RIGOL 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is selected, the result is the exponential average of the ⚫...
  • Page 94 Chapter 2 Functions of the Front Panel of GPSA RIGOL the span of the channel according to your needs, and then press Add Channel to add a channel. Table 2-37 Channel Span Parameter Remarks Default 3 GHz 10 Hz to 2*Min[(channel frequency –...
  • Page 95 Chapter 2 Functions of the Front Panel of GPSA RIGOL Occupied BW Measurement Interface: Figure 2-8 OBW Measurement Interface Measurement Results: occupied bandwidth and transmit frequency error. OBW: Use the integral calculation method to calculate the power within the ⚫...
  • Page 96 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-38 Average Count for OBW Measurement Parameter Remarks Default Range 1 to 1000 Unit None Knob Step Left/Right Arrow Key Step Up/Down Arrow Key Step 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential".
  • Page 97 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-39 Span for OBW Measurement Parameter Remarks Default 2 MHz Range 10 Hz to 6.5 GHz Unit GHz, MHz, kHz, Hz Knob Step OBW span/100, Min = 1 Hz...
  • Page 98 Chapter 2 Functions of the Front Panel of GPSA RIGOL Emission Bandwidth (EBW) Measurement Interface: Figure 2-9 EBW Measurement Interface Measurement Results: EBW, i.g. the bandwidth between two points on the signal which are X dB below the highest point within the span. During the measurement,...
  • Page 99 Chapter 2 Functions of the Front Panel of GPSA RIGOL 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is selected, the result is the exponential average of the ⚫...
  • Page 100 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-43 X dB for EBW Measurement Parameter Remarks Default -10 dB Range -100 dB to -0.1 dB Unit Knob Step 0.1 dB Left/Right Arrow Key Step Up/Down Arrow Key Step...
  • Page 101 Chapter 2 Functions of the Front Panel of GPSA RIGOL C/N Ratio (CNR) Measurement Interface: Carrier BW Offset Frequency Noise BW Figure 2-10 C/N Ratio Measurement Interface Measurement Results: carrier power, noise power, and C/N ratio. Carrier Power: power within the carrier bandwidth.
  • Page 102 Chapter 2 Functions of the Front Panel of GPSA RIGOL 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential". When "Exponential" is selected, the result is the exponential average of the ⚫...
  • Page 103 Chapter 2 Functions of the Front Panel of GPSA RIGOL range is from (noise bandwidth/20) to (noise bandwidth x 20). You can use the numeric keys, the knob, or arrow keys to modify this ⚫ parameter; you can also use the touch screen to modify the parameter.
  • Page 104 Chapter 2 Functions of the Front Panel of GPSA RIGOL Harmo Dist (THD) Measurement Interface: Figure 2-11 Harmonic Distortion Measurement Interface Measurement Results: The amplitude of each order of harmonic and THD (total harmonic distortion) of the carrier. At most, 10th-order harmonic can be measured.
  • Page 105 Chapter 2 Functions of the Front Panel of GPSA RIGOL is "Exponential". When "Exponential" is selected, the result is the exponential average of the ⚫ measurement results obtained in the past N times (N is specified in "Avg Number"). When "Repeat" is selected, the result is the arithmetic average of the ⚫...
  • Page 106 Chapter 2 Functions of the Front Panel of GPSA RIGOL Third-order Intercept (TOI) Measurement Interface: Lower Base Base Upp Lower 3rd Order 3rd Order Uppe Figure 2-12 TOI Measurement Interface Measurement Results: Base Lower, Base Upper, 3rd Order Lower, 3rd Order Upper, frequency and amplitude...
  • Page 107 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-51 Average Count for TOI Measurement Parameter Remarks Default Range 1 to 1,000 Unit None Knob Step Left/Right Arrow Key Step Up/Down Arrow Key Step 2. Avg Mode Sets the average mode to "Exponential" or "Repeat". The default average mode is "Exponential".
  • Page 108 VSWR: indicates the ratio of maximum voltage to minimum voltage in standing ⚫ wave pattern. VSWR bridge and the tracking generator (RSA5065-TG/RSA5032-TG) are required during measurement. Two measurements have to be performed according to the measurement wizard at the lower section of the interface: measurement with the DUT disconnected (represented by Trace6) and measurement with the DUT connected (represented by Trace1).
  • Page 109 Chapter 2 Functions of the Front Panel of GPSA RIGOL 2. Cal Open After you disconnect the instrument, press this key, and then the instrument executes the first measurement. The measurement result is represented by Trace6. 3. VSWR After you connect the instrument, press this key, and then the instrument executes the second measurement.
  • Page 110: Marker Measurement

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Marker Measurement Marker Marker is a triangle sign (as shown in the following figure), which is used for marking the point on the trace. Through the marker, you can read the amplitude and frequency of the point on the trace, or the sweep time point.
  • Page 111 Chapter 2 Functions of the Front Panel of GPSA RIGOL Selected Marker RSA5000 provides 8 markers. By default, Marker1 is selected under "Selected Marker". After you select a marker, you can set parameters such as the marker mode, the marker trace, and marker readout. The currently enabled marker will be marked on the trace selected under Marker Trace.
  • Page 112 Chapter 2 Functions of the Front Panel of GPSA RIGOL Application of the "Delta" Marker It is used to measure the S/N ratio of the single spectrum signal. Move the reference marker to the location where the signal resides, and move the Delta marker to the location where the noise resides.
  • Page 113 Chapter 2 Functions of the Front Panel of GPSA RIGOL determined by the instrument. When you disable the marker's auto marking trace function, whatever states of ⚫ the marker and the trace, the marker will be associated to the current marker trace.
  • Page 114 Chapter 2 Functions of the Front Panel of GPSA RIGOL 1. Frequency If you select "Frequency" to be the readout type, the "Position" and the "Fixed" marker modes display the absolute frequency; whereas the "Delta" marker mode displays the frequency difference between the Delta marker and the reference marker.
  • Page 115 Chapter 2 Functions of the Front Panel of GPSA RIGOL waveform display area. If the marker is not visible in the selected area, extend the marker line to the ⚫ display area for better observation. This function is useful for the marker outside the display area.
  • Page 116 Chapter 2 Functions of the Front Panel of GPSA RIGOL Figure 2-15 Marker Table Marker All Off Turns off all the enabled markers and their related functions. 2-72 RSA5000 User Guide...
  • Page 117: Marker To

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Marker To Sets the other system parameters (such as center frequency and reference level) by using the current marker values. Press any key under Marker To to activate a marker automatically if no marker is currently enabled.
  • Page 118 Chapter 2 Functions of the Front Panel of GPSA RIGOL Mkr->Ref Sets the reference level of the analyzer to the amplitude of the current marker. If Position marker is selected, the reference level will be set to the amplitude of ⚫...
  • Page 119: Marker Function

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Marker Function N dB State Enables or disables the N dB bandwidth measurement function. Note: In the N db measurement state, if the current marker is disabled, then the N dB BW measurement function is also disabled.
  • Page 120 Chapter 2 Functions of the Front Panel of GPSA RIGOL For details, refer to descriptions in "Parameter Setting". Table 2-55 N dB BW Parameter Settings Parameter Remarks Default -3.01 dB Range -140 dB to -0.01 dB Unit Knob Step 1 dB...
  • Page 121 Chapter 2 Functions of the Front Panel of GPSA RIGOL Band Adjust Adjusts the bandwidth parameters for the band function. 1. Band Span Sets the bandwidth of the signal involved in the calculation for the band function. 2. Band Left Sets the left edge frequency of the signal involved in the calculation for the band function.
  • Page 122 Chapter 2 Functions of the Front Panel of GPSA RIGOL Table 2-56 Gate Time Parameter Remarks Default 100 ms Range 1 μs to 500 ms Unit s, ms, μs, ns, ps Knob Step gate time/100, Min = 1 μs Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-1.5-2-3-5-7.5 step...
  • Page 123: Peak

    Chapter 2 Functions of the Front Panel of GPSA RIGOL Peak The peak search function enables the marker to move to the specific signal peak point, and then in combination with the function of Delta marker, it can provide a powerful analysis capability.
  • Page 124 Chapter 2 Functions of the Front Panel of GPSA RIGOL Pk-Pk Search Executes Peak Search and Minimum Peak functions at the same time, and marks the results with the Delta marker. Wherein, the result of Peak Search is marked with the reference marker and the result of Minimum Peak is marked with the Delta marker.
  • Page 125 Chapter 2 Functions of the Front Panel of GPSA RIGOL 3. Peak Excursion Sets the amplitude of the peak. It defines the minimum amplitude variation required for a signal to be identified as peak. Table 2-58 Peak Excursion Parameter Remarks...
  • Page 126 Chapter 2 Functions of the Front Panel of GPSA RIGOL 6. Search Mode Sets the peak search condition: maximum value on the trace or the parameter that meets the search criteria. The available options are Max and Para. If "Max" is selected, the system ⚫...
  • Page 127 Chapter 2 Functions of the Front Panel of GPSA RIGOL Figure 2-17 Peak Table Peak Table Sort Selects the peak table sorting rule. Two options are available: Freq and Ampl. That is, list the peak in the order of ascending frequency or descending amplitude.
  • Page 128 Chapter 2 Functions of the Front Panel of GPSA RIGOL Display Line Sets the display line level to change its display location. This line can be used as either the reference for you to read the measurement result or the threshold condition for the peaks displayed in the peak table.
  • Page 129: Chapter 3 Functions Of The Front Panel Of Rtsa

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Chapter 3 Functions of the Front Panel of RTSA The real-time spectrum analyzer (RTSA) contains the digital IF component that has a strong processing capability. In real-time mode, all signal samples are processed to produce measurement results or initiate a trigger.
  • Page 130: Basic Settings

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Basic Settings FREQ Press FREQ on the front panel to enter the frequency setting menu. In this menu, Center Frequency is, by default, selected. You can modify the frequency-related parameters in this menu.
  • Page 131 Chapter 3 Functions of the Front Panel of RTSA RIGOL Table 3-1 Span Parameter Remarks Default 25 MHz Range 5 kHz to 25 MHz Unit GHz, MHz, kHz, Hz Knob Step span/200, Min = 2 Hz Left/Right Arrow Key Step...
  • Page 132 Chapter 3 Functions of the Front Panel of RTSA RIGOL Note: The PvT measurement displays the power variation of the signal within the user-defined time. The horizontal axis represents time, and the vertical axis represents amplitude. Scale/Div (PvT) Sets the unit per division in the horizontal axis of the PvT view. Modifying this value will not cause you to restart measurements.
  • Page 133: Ampt

    Chapter 3 Functions of the Front Panel of RTSA RIGOL AMPT Press AMPT on the front panel to enter the amplitude setting menu. In this menu, Reference Level is, by default, selected. In non-PvT measurement mode and the PvT measurement mode (except the Ref Level and Scale/Div menus), for details about each item under this menu, refer to "AMPT"...
  • Page 134: Sweep And Function Settings

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Sweep and Function Settings Press BW to enter the bandwidth setting menu. In this menu, you can select the filter type and RBW. In RTSA mode, RBW selects from a pre-calculated selection of RBW values, which are computed based on the following formula: RBW = SPAN/Ratio.
  • Page 135 Chapter 3 Functions of the Front Panel of RTSA RIGOL Filter Type Sets the type of the FFT window function. RTSA adopts 6 filter types: Gaussian, Flattop, Blackman-Harris, Rectangular, Hanning, and Kaiser. You can select a proper filter type according to the actual measurement requirements.
  • Page 136: Sweep

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Sweep Press Sweep to enter the sweep setting menu. In this menu, set the sweep and control function of the analyzer. Acq Time Sets the acquisition time for producing one single trace or one persistence bitmap. In this mode, the generated single trace will combine multiple overlapped FFT analysis results.
  • Page 137 Chapter 3 Functions of the Front Panel of RTSA RIGOL Table 3-7 Acquisition Time Parameter Remarks Default 30.00 ms Range 0 s to 40 s Unit s, ms, μs, ns, ps Knob Step acquisition time/100, Min = 1 μs Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-1.5-2-3-5-7.5 step...
  • Page 138: Trigger

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Trigger Press Trigger on the front panel to enter the trigger setting menu. The settings for the trigger parameters are basically the same as that in GPSA. In RTSA, IF power trigger and FMT are added.
  • Page 139 Chapter 3 Functions of the Front Panel of RTSA RIGOL Table 3-9 Power Parameter Remarks Default 0 dBm Range (-140+level offset) to (30+level offset) Knob Step 1 dBm Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-3-10 step 1. Mask Type Determines which mask (upper or lower) is being displayed on the screen.
  • Page 140 Chapter 3 Functions of the Front Panel of RTSA RIGOL Figure 3-1 FMT Editing Interface 1) Active Mask Selects the mask type that needs to be activated currently. The following operations for editing and setting the mask points are only valid for the currently activated mask type.
  • Page 141 Chapter 3 Functions of the Front Panel of RTSA RIGOL 8) Build From Trace Selects a trace to build a mask. 9) Build Builds a mask from the selected trace. The mask points are generated based on the rough outline of the trace. You can use the X and Y offset to adjust the mask position.
  • Page 142 Chapter 3 Functions of the Front Panel of RTSA RIGOL 19) Y Axis Type When "Fixed" is selected, the amplitude of the current editing point will not be affected by the reference level. When "Relative" is selected, the amplitude of the current mask point is the difference between the amplitude of the current mask point and the current reference level.
  • Page 143: Trace

    Chapter 3 Functions of the Front Panel of RTSA RIGOL where the signal passes back into the mask. Trace Press Trace on the front panel to enter the trace setting menu. In this menu, you can perform the operations related to trace, such as trace acquisition, trace display, trace saving, trace detector, and trace data.
  • Page 144 Chapter 3 Functions of the Front Panel of RTSA RIGOL Trace Detector (PvT) Sets the trace detector for the PvT mode. Detector Auto (PvT) Enables or disables the Detector Auto function in PvT mode. By default, Detector Auto is enabled. If you set the detector type manually, please disable the Detector Auto function.
  • Page 145: Measurement Settings

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Measurement Settings Meas In RTSA mode, Normal, Density, Spectrogram, Density Spectrogram, PvT, PvT Spectrum, PvT Spectrogram, and AMK are available. After you select a measurement function, the screen is split into several display windows;...
  • Page 146 Chapter 3 Functions of the Front Panel of RTSA RIGOL Density Measurement Interface: Figure 3-2 Density View The instrument defaults to Density measurement mode, and the measurement interface is shown in the figure above. After you select Density to be the measurement type, press Meas Setup to set the relevant parameters.
  • Page 147 Chapter 3 Functions of the Front Panel of RTSA RIGOL Spectrogram Measurement Interface: Figure 3-3 Spectrogram View After you select Spectrogram to be the measurement type, the measurement interface is shown in the figure above. Press Meas Setup to set the relevant parameters.
  • Page 148 Chapter 3 Functions of the Front Panel of RTSA RIGOL When you select a trace that has not yet been acquired, both the trace window ⚫ and Spectrogram window will remain blank until the trace is acquired. Then, once a trace is acquired in the Spectrogram window, the window will be updated for one time.
  • Page 149 Chapter 3 Functions of the Front Panel of RTSA RIGOL relationship. You can use the mouse or touch the screen to display one of the windows in full screen. The parameter rule in the Density view is consistent with that in the single ⚫...
  • Page 150 Chapter 3 Functions of the Front Panel of RTSA RIGOL Spectrogram and PvT Spectrum, the acquisition time of the real-time spectrum measurement will be set to the PvT acquisition time. The menu items under BW in PvT measurement are disabled. The menu items ⚫...
  • Page 151 Chapter 3 Functions of the Front Panel of RTSA RIGOL PvT Spectrogram Measurement Interface: Figure 3-7 PvT Spectrogram View After you select PvT Spectrogram to be the measurement type, the measurement interface is shown in the figure above. Press Meas Setup to set the relevant parameters.
  • Page 152 Chapter 3 Functions of the Front Panel of RTSA RIGOL Advanced Measurement Function (AMK) Measurement Interface: Figure 3-8 SSC Measurement Interface (1) Meas Off Disables the advanced measurement function and returns to the Normal view in RTSA mode. (2) SSC SSC advance measurement function is a measurement analysis function specially customized for 2FSK signal.
  • Page 153: Meas Setup

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Meas Setup Open the parameter setting menu of the function selected in the Meas menu. In the Meas Setup menu, only the menu items related to the current measurement function are displayed. Please view the relevant menus according to the current measurement function.
  • Page 154 Chapter 3 Functions of the Front Panel of RTSA RIGOL Density Parameters 1. Persistence Sets how long the frequency/amplitude points displayed in the bitmap should take to fade. Remarks: The persistence controls the length of time it will take for a point to go from ⚫...
  • Page 155 Chapter 3 Functions of the Front Panel of RTSA RIGOL Table 3-12 Lowest Density Hue Parameter Remarks Default Range 0 to 99.9 Unit None Knob Step Left/Right Arrow Key Step Up/Down Arrow Key Step at 1-1.5-2-3-5-7.5 step 6. Curve Nonlinearity...
  • Page 156 Chapter 3 Functions of the Front Panel of RTSA RIGOL Spectrogram Parameters 1. Display Trace Sets the trace index displayed in the trace window in the Spectrogram mode. You can determine the trace either by the trace number or the trace time. Trace 1 indicates the latest trace.
  • Page 157 Chapter 3 Functions of the Front Panel of RTSA RIGOL The hues of the colors run from 0 to 359 are shown below: In the hue ring, Hue 0 is red (255,0,0), Hue 120 is green (0,255,0), Hue 240 is blue (0,0,255), Hue 60 is yellow (255,255,0), Hue 180 is Cyan (0,255,255), and Hue 300 is magenta (255,0,255).
  • Page 158 Chapter 3 Functions of the Front Panel of RTSA RIGOL Table 3-17 Bottom Hue Position Parameter Remarks Default 0 to Min (90%, reference Range position value - 10%) Unit None Knob Step Left/Right Arrow Key Step Up/Down Arrow Key Step 7.
  • Page 159 Chapter 3 Functions of the Front Panel of RTSA RIGOL can also use the touch screen to modify the value. 7) Pass/Fail Enables or disables the Pass/Fail function. Before enabling the Pass/Fail function, refer to the descriptions in the following section to edit the limit.
  • Page 160: Marker Setup

    Chapter 3 Functions of the Front Panel of RTSA RIGOL Marker Setup Marker In RTSA mode, the Marker function in the real-time spectrum view is basically the same as that for GPSA (Note that when you select the Density view or the Spectrum view, the Marker Z menu is enabled).
  • Page 161: Chapter 4 Input/Output

    The default input impedance is 50 Ω. To measure a 75 Ω device, you should use a 75 Ω to 50 Ω adapter (option) supplied by RIGOL to connect the analyzer with the system under test, and then set the input impedance to 75 Ω.
  • Page 163: Chapter 5 Shortcut Key

    Chapter 5 Shortcut Key RIGOL Chapter 5 Shortcut Key Auto Tune Automatically searches for the signal within the full frequency range, and adjusts the frequency and amplitude for optimal display effect of the signal to realize one-key signal search and auto setting of parameters.
  • Page 164 Chapter 5 Shortcut Key RIGOL Figure 5-2 After Auto Search Remarks: In the process of auto search, the backlight of the Auto Tune key on the front ⚫ panel turns on. After the search is finished, the backlight of the key turns off.
  • Page 165: Preset

    Chapter 5 Shortcut Key RIGOL Preset Recalls the preset setting and restores the system settings of the analyzer to a specified status. Remarks: To set the preset type, press System → Preset → Preset Type to select ⚫ "Default" or any one of the items from "User1" to "User6".
  • Page 166 Chapter 5 Shortcut Key RIGOL Sweep Points Sweep Time Auto, 1 ms Acq Time Auto, 31.9960 Auto, 21.9855 Sweep Time Mode Continuous Continuous Sweep Time Rule Normal Trigger Trigger Source Free Run Free Run Trigger Holdoff Off, 100 ms Off, 100 ms...
  • Page 167 Chapter 5 Shortcut Key RIGOL Reference Position 100% Reference Trace Mode Measurement Mode GPSA Mode Setup Global CF Mode Off, 3.25 GHz Off, 3.25 GHz Meas Measurement Function Swept SA Normal Measurement Measure Setup (GPSA) Swept SA Measurement Avg Number...
  • Page 168 Chapter 5 Shortcut Key RIGOL Avg Mode Exponential Avg State Main Chan BW 2 MHz Adj Chan BW 2 MHz Chan Spacing 2 MHz Multichan Pwr Avg Number Off, 10 Avg Mode Exponential Avg State Channel Span 3 GMHz Channel Sheet Channel Freq 3.25 GHz...
  • Page 169 Chapter 5 Shortcut Key RIGOL Measure Setup (RTSA) Normal Avg Number Test Limits Select Limit Limit1 Limit State Test Trace Trace1 Limit Type Upper X to CF Relative Y to Ref Relative Margin Off, 0 dB Frequency 0 Hz Amplitude...
  • Page 170 User key Language English English Note : This function is only available for RSA5065-TG/RSA5032-TG working in GPSA mode. Note : This function is only available for RSA5000 installed with the corresponding option. Note : Not affected by Preset settings. RSA5000 User Guide...
  • Page 171: User

    Chapter 5 Shortcut Key RIGOL User User-defined shortcut key. For some hard-to-find but commonly used function menu, you can define it as shortcut key (for the defining method, refer to the introduction in "User Key"). After that, press the shortcut key under any operation interface to quickly open and set the desired menu or function.
  • Page 173: Chapter 6 System Function

    Chapter 6 System Function RIGOL Chapter 6 System Function System Sets the system parameters. Preset Functions include: select the instrument settings to be recalled after the analyzer is powered on ("Last" or "Preset"); set the preset type ("Factory" or one of the items from "User1"...
  • Page 174 Chapter 6 System Function RIGOL Alignment 1. Align Now Press this key and the analyzer will use the internal calibration source to perform a self-calibration immediately. 2. Align Auto Enables or disables self-calibration. If self-calibration is enabled, the analyzer will perform one self-calibration after being started.
  • Page 175 Chapter 6 System Function RIGOL analyzer based on the current network configuration. Auto: When "Auto" is selected, the instrument will acquire the IP ⚫ address ranging from "169.254.0.1" to "169.254.255.254" and the subnet mask (255.255.0.0) automatically based on the current network configuration.
  • Page 176 Chapter 6 System Function RIGOL After the LAN interface configuration is finished, press this key to apply the current configuration to the instrument. 7) Reset Turns on DHCP and Auto-IP; turns Manual-IP off. Clears the set network password and restores it to the factory defaults.
  • Page 177 ⚫ 2. Option Info Displays the option information. RSA5000 provides many kinds of options to meet various measurement requirements. To purchase the corresponding option, please contact RIGOL. 3. Self Test Screen ⚫ Tests whether the screen has a dot defect by using six colors: blue, red, green, gray, white, and black.
  • Page 178 Chapter 6 System Function RIGOL exit the test. Multi-point Touch ⚫ Enters the multi-point touch test interface. Use multiple fingers to make pinch or stretch gestures on the screen, and observe the size of the characters. If they do not change along with your gestures, it indicates that problems occurred to the multi-point touch function.
  • Page 179 Chapter 6 System Function RIGOL Security Clear Press this key to perform the security clear function. This function includes the following operations: Deletes all the files that users have saved, including the state files, trace state ⚫ files, screen files, measdata files, and limit files saved by users in all modes.
  • Page 180 Chapter 6 System Function RIGOL Messages Press this key, and then a prompt message dialog box will be displayed. You can press the corresponding softkey to select to view all the messages, the messages that have been read or not read. You can also use the touch screen or the externally connected mouse to tap or click the specified icon in the prompt message dialog box.
  • Page 181: File

    Chapter 6 System Function RIGOL File RSA5000 allows you to save various types of files to the internal or external memory, and recall them when necessary. Press File on the front panel to enter the file operation menu interface. File Explorer Press the key to enter the file manager interface.
  • Page 182 Chapter 6 System Function RIGOL Table 6-2 Descriptions of File Type File Type Format Suffix Name State .sta Trace+State .trs Measurement Data .csv Limit .csv Screen Image IMAGE .jpg/bmp/png License LICENSE .lic .csv Note: RSA5000 can only recognize files whose filenames consist of Chinese characters, English letters, or numbers.
  • Page 183 Chapter 6 System Function RIGOL New Folder Creates a folder. Press this key to create a new empty folder under the current directory, and the file is named with a default filename. To modify this filename, press Rename to rename the file.
  • Page 184 Chapter 6 System Function RIGOL In addition, you can preview the print page, and set to print the image or the text in All page, 1/2, 1/4, or 1/9 page. 2. Add Device Queries and adds a printer. Inputs the IP address of the printer, the manufacturer of the printer, the printer model, and printer drive.
  • Page 185: Recall

    Chapter 6 System Function RIGOL Recall RSA5000 allows you to recall various types of files saved to the internal or external storage memory. Press Recall on the front panel to enter the file recalling menu. The available file types include: State, Trace+State, Measurement Data, Limit, and FMT (only available for RTSA).
  • Page 186 Chapter 6 System Function RIGOL Measurement Data Press Measurement Data to enter the measurement data recalling menu. 1. Recall Press File Explorer to enter the file manager interface. Select a file and then press Recall to recall the file. 2. To Trace Selects the measurement data file and recalls it to the selected trace.
  • Page 187: Save

    Chapter 6 System Function RIGOL Save RSA5000 allows you to save various types of files to the internal or external memory. Press Save on the front panel to enter the file saving menu. The available file types include: State, Trace+State, Measurement Data, Limit, Screen Image, and FMT (only available for RTSA).
  • Page 188 Chapter 6 System Function RIGOL Trace+State Press Trace+State to enter the trace+state saving menu. The state of the instrument and the selected trace can be saved to the register or the file. 1. Save Press this key to save the current trace+state file in the default filename or user-defined filename.
  • Page 189 Chapter 6 System Function RIGOL 1. Save Press this key to save the currently selected type of measurement data in the default filename or user-defined filename. The default filename is determined by the following methods: If you haven't input a filename by pressing the Save As key, its default ⚫...
  • Page 190 Chapter 6 System Function RIGOL is saved to be "abc.csv". After that, press the key again, another file is saved automatically with the filename "abc1.csv". 2. Save As Press this key and then use the numeric keypad on the front panel to input the filename.
  • Page 191 Chapter 6 System Function RIGOL Color Type Press this key to select the color of the current screen image to be "Normal" or "Inverted". FMT (only available for RTSA) Press FMT to enter the FMT file saving menu. Save the selected FMT file to the file.
  • Page 193: Chapter 7 Remote Control

    Chapter 7 Remote Control RIGOL Chapter 7 Remote Control You can control RSA5000 series spectrum analyzer through USB or LAN remote interface. This chapter introduces remote control and the control method. Contents in this chapter: Remote Control Overview ◼ Remote Control via USB ◼...
  • Page 194: Remote Control Overview

    Please refer to Ultra Sigma help documentation to install the software and the required components correctly. You can download the latest version of the software from www.rigol.com. Note: When the instrument is in remote mode, the front panel keys (except the Power key and Esc) are locked.
  • Page 195: Remote Control Via Usb

    PC. You can also click to search for the resource. 4. View the device resource The resources found will appear under the "RIGOL Online Resource" directory, and the model number and USB interface information of the instrument will also be displayed.
  • Page 196: Remote Control Via Lan

    LAN interface. If you want to remove the resource, please select the resource name, and then click to remove it. 4. View the device resource The resources found are shown under the “RIGOL Online Resource” directory. For example, RSA5065 (TCPIP::172.16.3.194::INSTR). 5. Communication test Right-click the resource name "RSA5065 (TCPIP::172.16.3.194::INSTR)" and select "SCPI Panel Control"...
  • Page 197 Note: If you want to view or modify the network settings of this instrument, please click Network Settings and then a pop-up window is displayed. Input "rigol" ("rigol" must be in lowercase form, without quotation marks) in the user name and the password fields. Besides, you can click Security to reset the password.
  • Page 199: Chapter 8 Troubleshooting

    The commonly encountered failures of the analyzer and their solutions are listed below. If the following problems occur, locate and resolve the problems according to the following steps. If the problems still persist, contact RIGOL and provide your instrument information to us. (For instrument information, press System → About System →...
  • Page 200 (4) Calibrate the instrument regularly to reduce or avoid measurement errors that might occur due to device aging. — If you need calibration after the stated calibration period expires, contact RIGOL or get paid service from authorized measurement agencies. — The analyzer provides self-calibration function. If required, press System →...
  • Page 201: Chapter 9 Appendix

    Real-time Spectrum Analyzer, 9 kHz to 3.2 GHz (include RSA5032-TG Real-time Spectrum Analyzer, 9 kHz to 6.5 GHz (include Model RSA5065-TG Real-time Spectrum Analyzer, 9 kHz to 3.2 GHz (include TG RSA5032N and VNA) Real-time Spectrum Analyzer, 9 kHz to 6.5 GHz (include TG...
  • Page 202 VSWR Bridge, 2 GHz to 8 GHz VB1080 Near-field Probe NFP-3 Rack Mount Kit RM6041 CB-USBA-USBB-FF USB Cable -150 Note: For more details about the accessories and the options, please contact RIGOL sales representatives or the local distributors. RSA5000 User Guide...
  • Page 203: Appendix B: Warranty

    If a product proves defective within the warranty period, RIGOL guarantees free replacement or repair for the defective product. To get repair service, please contact with your nearest RIGOL sales or service office. There is no other warranty, expressed or implied, except such as is expressly set forth herein or other applicable warranty card.
  • Page 205: Index

    Index RIGOL Index 3rd Order Lower ....... 2-62 Keyboard Test ......6-6 3rd Order Upper ....... 2-62 LAN .......... 6-2 ACP ......... 2-35, 2-45 Last Span ......2-8, 3-3 Acq Times/Trigger ..... 3-10 Main Channel Bandwidth .... 2-46 Adjacent Channel Bandwidth ..2-46 Main Channel Power ....
  • Page 206 Index RIGOL PvT Spectrum ......3-22 Start Line ......... 2-43 RBW........2-14 Stop Freq ........2-4 Readout ........2-69 Stop Line ........2-43 Reference Level ......2-9 Subnet Mask ....... 6-3 Reference Level Offset ....2-13 Sweep Time ......2-18 Reference Marker .....

This manual is also suitable for:

Rsa5000 seriesRsa5032-tgRsa5065Rsa5032Rsa5065nRsa5032n

Table of Contents