TOT- TX timeout timer

G18 can be programmed with a transmission timer that temporarily
blocks transmissions if the radio has been used beyond the maximum
time permitted.
The radio is forced to reception mode if it continues transmitting after
the preset timer threshold has been reached.
To restart the transmission, release the PTT key.
To enable this function:
1.
Press the MENU button;
2.
Turn the Encoder knob until "TOT" is displayed;
3.
Push ENT to enter the function;
4.
Turn the Encoder knob and set a timer from 30 to 270
seconds.
5.
Confirm selection with ENT.

SCAN mode settings

Press MENU and then rotate the Encoder knob. The display will show
"SCANS".
Press ENTER and then rotate the Encoder knob to choose the type of
Scan (TO/CO/SE).
Confirm your selection with ENT.
TO - Time-operated Scan
Whenever a signal is detected, the radio will suspend the scan for 5
seconds, and then will continue to scan even if the signal is still present.
CO: Carrier-operated Scan
Whenever a signal is detected, the radio will stop scanning.
It will resume scanning
resume scanning once the signal is no longer detected.
SE: Search Scan
The radio will stop scanning and exit the Scan mode once a signal is
detected.