SLP99UH090XV48C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
BLOWER DATA
SLP99UH090XV60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between.
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28% and 38% (DIP switch selectable) of the same second-stage COOL speed position.
minimum 380 cfm.
Lennox
Smart Zoning System Applications - Minimum blower speed is 450 cfm.
®
35%
40%
769
835
713
776
656
716
595
652
534
589
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
815
975
1095
745
885
1005
675
810
910
35%
40%
583
665
540
618
497
571
439
507
380
443
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1105
1280
1400
1015
1165
1285
920
1055
1165
Page 47
Heating Input Range and Blower Volume - CFM
50%
60%
968
1101
902
1028
836
955
767
882
699
809
Blower Speed Selections
High
Low
(Default)
1270
1125
1145
1030
1040
950
Heating Input Range and Blower Volume - CFM
50%
60%
830
995
774
930
718
865
644
781
570
697
Blower Speed Selections
High
Low
(Default)
1590
1590
1425
1425
1295
1290
70%
80%
90%
1234
1367
1500
1155
1281
1407
1075
1195
1314
997
1112
1227
919
1029
1139
Second Stage Cool Speed - cfm
Medium-
Medium
Low
High
1375
1565
1235
1445
1115
1305
70%
80%
90%
1159
1324
1488
1085
1241
1397
1012
1159
1306
917
1054
1191
823
950
1076
Second Stage Cool Speed - cfm
Medium-
Medium
Low
High
1820
2025
1635
1855
1470
1655
100%
1633
1534
1434
1342
1249
High
(Default)
1785
1615
1480
100%
1653
1553
1453
1328
1203
High
(Default)
2270
2035
1855