3. Operation
3.6. 3D i-see Sensor setting
Note:
This function cannot be set depending on the outdoor unit to be
connected.
3.6.1 3D i-see Sensor setting
Main
Main menu
Operation
F1
F2
F3
F4
Operation
Vane·3D i-See·Vent. (Lossnay)
High power
Comfort
Main menu:
Cursor
F1
F2
F3
F4
Comfort
Manual vane angle
3D i-See sensor
Setting display:
Cursor
F1
F2
F3
F4
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display:
Cursor
F1
F2
F3
F4
1 Select "Operation" from the Main
menu, and press the [SELECT]
button.
2 Select "Comfort" from the
Operation menu, and press the
[SELECT] button.
3 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT] button.
4 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal airflow
When the thermostat turns off,
the fan and the vanes operate
according to the control settings.
3.6.2 Air distribution
Air distribution
Ref. address
Unit No.
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Air distribution
Ref. address
Unit No.
All
Auto vane
Direct/Indirect
Direct/Indirect setting
Select:
Cur.
F1
F2
F3
F4
Direct
Cooling
horizontal → swing
Heating
keep downward
Direct/Indirect setting
: Direct
: Indirect
: Indirect
: Direct
Select:
Angle
Outlet
F1
F2
F3
F4
1 Move the cursor to "Ref. address"
or "Unit No." with the [F1] button
to select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4]
button.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the
same as during normal operation.
"Area"*: The vanes move to the
down airflow direction toward
areas with a high floor temperature
during cooling mode and toward
areas with a low floor temperature
during heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
"Direct/Indirect"*: The vanes
automatically move relative to
the areas where persons are
detected.
The vanes operate as indicated in
the following table.
* In order to enable this function,
the airflow direction must be set to
"Auto".
Vane setting
Indirect
keep horizontal
downward → horizontal
3 When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT]
button to save the settings.