Download Print this page

GreenWorks PowerHub GWU-GreenE SYSTEM Quick Installation Manual page 7

Advertisement

Overview of Terminals
No.
Terminals
Port Pin
Pin 1: CT L1B+
CT L1B terminal
20
Pin 2: CT L1B-
Pin 1: CT L2A+
CT L2A terminal
21
Pin 2: CT L2A-
Pin 1: CT L2B+
CT L2B terminal
22
Pin 2: CT L2B-
BI breaker and switch (Purchased by customer)
No.
Component
Description
Amps Part Number Description
100
CSR2100
Eaton # CSR2100: 100 A / 240 V, 25 kAIC, 2-Pole
125
CSR2125N
Eaton # CSR2125N: 125 A / 240 V, 25 kAIC, 2-Pole
150
CSR2150N
Eaton # CSR2150N: 150 A / 240 V, 25 kAIC, 2-Pole
175
CSR2175N
Eaton # CSR2175N: 175 A / 240 V, 25 kAIC, 2-Pole
200
CSR2200N
Eaton # CSR2200N: 200 A / 240 V, 25 kAIC, 2-Pole
100
BW2100
Eaton # BW2100: 100 A / 240 V, 10 kAIC, 2-Pole
125
BW2125
Eaton # BW2125: 125 A / 240 V, 10 kAIC, 2-Pole
1
Grid breaker
150
BW2150
Eaton # BW2150: 150 A / 240 V, 10 kAIC, 2-Pole
175
BW2175
Eaton # BW2175: 175 A / 240 V, 10 kAIC, 2-Pole
200
BW2200
Eaton # BW2200: 200 A / 240 V, 10 kAIC, 2-Pole
100
BWH2100
Eaton # BWH2100: 100 A / 240 V, 25 kAIC, 2-Pole
125
BWH2125
Eaton # BWH2125: 125 A / 240 V, 25 kAIC, 2-Pole
150
BWH2150
Eaton # BWH2150: 150 A / 240 V, 25 kAIC, 2-Pole
175
BWH2175
Eaton # BWH2175: 175 A / 240 V, 25 kAIC, 2-Pole
200
BWH2200
Eaton # BWH2200: 200 A / 240 V, 25 kAIC, 2-Pole
Emergency
Normally closed (NC) contact
2
stop switch
The UL certification is required for the emergency stop switch.
10
Torque
Type
Range
Strip Length
(in-lbs)
Shielded,
/
/
/
twisted pair
Shielded,
/
/
/
twisted pair
Shielded,
/
/
/
twisted pair
3. Mechanical Installation (Floor-mounting)
Weight and mounting height instructions
4 Batteries
844 mm
33.23 in
Inverter
BMS
Battery
Battery
Battery
Battery
Base
Weight(lb/kg): 591/268
2 Batteries
844 mm
33.23 in
Inverter
BMS
Battery
Battery
Base
Weight(lb/kg): 353/160
Mechanical Installation
3 Batteries
844 mm
33.23 in
Inverter
BMS
Battery
Battery
Battery
Base
Weight(lb/kg): 472/214
11

Advertisement