Download Print this page

Sanyo ECR-238 Service Manual page 7

Hide thumbs Also See for ECR-238:

Advertisement

@ EMERGENCY RESET
When
the Interlocking
(such as no key entry) is
happened, please try the following operations.
a. Unplug the machine from the AC power.
b. Turn the mode lock to the "P" position.
c. While depressing the [Paper Feed] key, plug the
machine to AC outlet.
d. Check the machine if the interlocking is released.
e, Reprogram the associated items.
@ 1.P.L (Initial Programming Loading)
Before using the register, it should first initialize the
total that memory and programming area currently
contained in memory, including the key codes. After
initialization,
the
machine
will
load
the
pre-
programmed data into memory.
Key Sequence
<P mode>
55--[ST ALL]--XX--[#/NS] ... Tax mode
99--[ST ALL]--XX--[#/NS] ... Tax mode (for CANADA)
99--[ST ALL]--XX--[#/NS] ... Non-Tax
XX: machine number (0~99)
If you have not programmed the machine number
yet, please enter one (1) as machine number.
@ AUTO LOADING KEYBOARD
After the memory
initialisation, you must utilize the
following procedures to assign the pre-programmed
key codes on the keyboard.
Key Sequence
<P mode>
44--[ST ALL]--XX--[#/NS]
XX : machine number (0~99)
® GT's & Z Counter INITIALIZATION
You can initialize the Grand Total memory
and Z
counters through the following procedures.
Key Sequence
<P mode>
88--[ST ALL]--XX--[#/NS]
XX : machine number (0~99)
Note : Grand Total has two separate memories.
Grand Total 1 = Sales Department Total
+ Tax Total
+ Void Total
+ Received-on-Account total
+ Paid Out Total
+ Amount Discount Total
+ Percent Discount Total
+ Percent Mark-up Total
+ Refund Total
Grand Total 2 = GROSS SALES
= NET SALES + TAX COLLECTED
© RESET (2) TOTAL
If you want to look at the data and reset the totals and
counters to zero, you would follow the procedure
utilizing the Z mode.
General
DAILY
CASH
Report
PERIODIC | ID code [CASH
PLU Report
Hourly
Daily
Total Report
CHEQUE

Advertisement