Troubleshooting/Specifications - Snapper 033001 Operator's Manual

Outdoor portable generator

Advertisement

Available languages

Available languages

Problem
Engine is running, but no AC
output is available.
Engine runs well at no-load but
"bogs down" when loads are
connected.
Engine will not start; starts and
runs rough or shuts down when
running.
Engine shuts down and CO
Guard LED blinks red (• • ••) .
For all other issues, see a Snapper authorized dealer.
Specifications
Model 033001
Rated Wattage* . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,500
Starting Wattage**. . . . . . . . . . . . . . . . . . . . . . . . . 4,375
AC Current at 120 Volts . . . . . . . . . . . . . . . . 29.1 Amps
Power Ratings: The net torque rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive
Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1349. Net torque values
are derived at 3600 RPM and are taken with exhaust and air cleaner installed. Given the wide array of conditions in which they are
placed, the gasoline engine may not develop the rated net torque when used in a given piece of power equipment. This difference is
due to a variety of factors including, but not limited to, the variety of application limitations, ambient operating conditions (temperature,
humidity, altitude), and engine-to-engine variability. Due to manufacturing and capacity limitations, JD North America Corp. may
substitute an engine of higher rated torque for this engine.
* Generator per PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018, Safety and Performance of
Portable Generators.
**Per Briggs & Stratton 628k
Cause
1. One of the circuit breakers is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
1. Generator is overloaded.
1. Engine switch set to off (0) position.
2. Fuel valve is in off (0) position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Spark plug wire not connected to
spark plug.
7. Flooded with fuel.
1. Generator improperly located.

Troubleshooting/Specifications

Correction
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
1. See Generator Capacity.
1. Set switch to on (I) position.
2. Turn fuel valve to on (I) position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Connect wire to spark plug.
7. Wait 5 minutes and re-crank engine.
1. Move generator to an open,
outdoor area. Air out premises (e.g.
open windows and doors) before
reoccupying. See CO Guard Carbon
Monoxide (CO) Shutdown System.
Common Specifications
Frequency . . . . . . . . . . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
Displacement . . . . . . . . . . . . . . . . 12.69 cu. in. (208 cc)
Spark Plug Gap . . . . . . . . . . . . . . . 0.030 in. (0.76 mm)
Fuel Capacity . . . . . . . 3.3 U.S. Gallons (12.5 Liters)
Oil Capacity . . . . . . . . . . . . . . . .20 Ounces (0.6 Liters)
15