Parts Description; Installation - AND LCM13-M Series Instruction Manual

Weigh module
Table of Contents

Advertisement

Bolts and nuts to secure the weigh module are not provided and must be prepared by the user.
To secure the weigh module, use bolts with a nominal diameter of M12 and a strength class of
10.9 or higher.
Be sure to remove the retainer plates after installation. Store the removed retainer plates and screws
as they may be used in the future for weigh module maintenance.
When installing the weigh module, refer to
section.
1.
Align and machine the mounting holes on the foundation structure and on the bracket for the
tank to secure the weigh module.
2.
Insert a jack between the foundation structure and the bracket and raise the tank to install the
weigh module.
3.
Secure the lower mount fixture to the foundation structure temporarily using the washers and
bolts.
4.
While aligning the foundation structure, the bracket, and the weigh module, lower the tank slowly
and secure the upper mount fixture to the bracket using the bolts.
5.
Lower the tank completely and remove the retainer plates.
Confirm that there is a gap between the stopper bolt and the upper mount fixture, and between
the stopper bolt and the bracket, as shown in the illustration on the next page.
Confirm that the upper and lower mount fixtures are aligned within 1 mm using the reference line
as shown in the illustration. For adjustment, raise the tank slightly and fine adjust the position of
the lower mount fixture.