Idem NET-BOX-PS Operating Instructions Manual

Idem NET-BOX-PS Operating Instructions Manual

Safety switches

Advertisement

Quick Links

IDEM Safety Switches
NET-BOX-PS
RFID Guard Interlock with additional Safety IO, Standard IO, and integrated PROFINET with PROFIsafe.
Operating Instructions
Original Instructions - To request this document in other languages please contact
info@idemsafety.com

Advertisement

Table of Contents
loading

Summary of Contents for Idem NET-BOX-PS

  • Page 1 IDEM Safety Switches NET-BOX-PS RFID Guard Interlock with additional Safety IO, Standard IO, and integrated PROFINET with PROFIsafe. Operating Instructions Original Instructions - To request this document in other languages please contact info@idemsafety.com...
  • Page 2: Table Of Contents

    Safety Inputs ........................8 Safety Outputs ........................8 Mechanical Data ......................... 9 Environmental Data ......................9 Reliability / Safety Data (EN ISO 13849-1) ................9 Reliability / Safety Data (EN 62061 / IEC 61508) ..............9 102637 2303 NET-BOX-PS Operating Instructions Contents...
  • Page 3: System Overview

    All relevant safety regulations and standards are to be observed. The NET-BOX-PS complies with the requirements of Cat. 4 / PL e and SIL 3 in accordance with ISO 13849-1, IEC 62061 and IEC 61508. The device implements the following safety functions: •...
  • Page 4: Installation & Maintenance

    Repair or modification of the NET-BOX is not allowed unless authorised by IDEM and carried out according to operating guidelines. • Safety critical failures which do not lead to the safe state shall be reported to IDEM immediately. • Replace a malfunctioning NET-BOX immediately.
  • Page 5: Electrical Connection

    • Not all connections are required for all applications, the minimum requirement to operate the device is one data connection and one power connection. All 4 ports are utilised when the NET-BOX is used a ‘daisy chain’ configuration. 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 6: Protocol Setup

    Replace the NET-BOX Lid and Lid screws, ensuring a tight seal of the lid. INFORMATION • The example given in the image above shows only switches 2, 16 and 64 set to the ‘ON’ position. When adding these numbers up the resulting F-Address is 82. 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 7: Profinet/Profisafe Configuration

    After the detection of a safety critical error, the NET-BOX shall not be kept in fail- safe state for more than 1 hour. INFORMATION • The device GSDML file can be found via the NET-BOX product page of the IDEM website www.idemsafety.com/products or alternatively please contact technical@idemsafety.com PROFINET/PROFIsafe Configuration Download the GSDML file for the NET-BOX and import into the application control software.
  • Page 8: Factory Reset

    • Expected operation of all control circuits. 6. Data Map See configuration specific technical datasheet supplied with product. For assistance please contact: technical@idemsafety.com 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 9: Diagnostic Indication

    Diagnostic LED’s are not reliable indicators and cannot be guaranteed to provide accurate information. They should only be used for general diagnostics during commissioning or troubleshooting. Do not attempt to use LEDs as operational indicators. 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 10: Technical

    Voltage Digital Input Low Current Digital Input High Current Digital Input Low Safety Outputs Parameter Unit Typ. Voltage Digital Output High 19.2 Current Digital Output High Current Digital Output Low Inductive Load Capacitive Load Short Circuit Peak 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 11: Mechanical Data

    Mission Time 20 years SIL CL SIL 3 PFHd 2.3E-9 (Emergency Stop Function) PFHd Safety Inputs 2.4E-9 (voltage free contacts with test pulses) PFHd Safety Inputs 2.4E-9 (OSSD inputs to device) PFHd Safety Outputs 2.4E-9 102637 2303 NET-BOX-PS Operating Instructions...
  • Page 12 EC / EU Declaration of Conformity MANUFACTURER: EU REPRESENTITIVE: ADDRESSES: IDEM SAFETY SWITCHES LIMITED IDEM SAFETY SWITCHES Ro SRL Hindley Industrial Estate Hindley Green Bloc OD6, nr. 35 Wigan Bulevardul Timișoara Lancashire București WN2 4HR 061344 United Kingdom Romania DEVICE(s):...

Table of Contents