7. Diagnostic Indication

LED
LED State
Green
DS
Red
Green
PS
Green Flash
Red
Off
Green
Green flash 1Hz
Green 1 flash
PN
Red
Red 1 flash
Red 2 flashes
Red 3 flashes
Red 4 flashes
Off
L1/L2
Amber
Amber flash
Diagnostic LED's are not reliable indicators and cannot be guaranteed to provide accurate
information. They should only be used for general diagnostics during commissioning or
troubleshooting. Do not attempt to use LEDs as operational indicators.
102637 2303 NET-BOX-PS Operating Instructions
LED
Function
DS
Device state
PS
PROFIsafe
PN
PROFINET/Network
L1
Link 1
L2
Link 2
Comment
Device running
Internal fault detected
PROFIsafe OK
PROFIsafe Integration required
Safe input fault detected, reset qualifier bits
Not initialised
Normal operation
Locate PROFINET device
Diagnostic event present
Exception
Configuration error
IP address not set
Station name not set
Internal error
No Ethernet link detected
Ethernet link detected
Ethernet data transfer
IDEM Safety Switches
Colour
Red/Green
Red/Green
Red/Green
Amber/Green
Amber/Green