Download Print this page

Idem LSPS-R Series Operating Instructions

Iec safety limit switch

Advertisement

Quick Links

Application:
IDEM LSPS-R Limit Switches with Reset Button are designed to be mounted for position sensing of moving applications e.g. guard doors, conveyors, machine beds, elevators etc.
They are available with linear plungers, rotary levers or roller plungers and either slow or snap action contacts. All contact blocks are positively operated to satisfy IEC 60947-5-1.
Operation:
Operation of the switches is achieved by a sliding actuation of the moving object to cause deflection of the switch plungers or levers.
For safety applications it is important that the moving object does not pass completely over the switch actuators so as to cause the actuator to return to its original position.
Installation guide: Correct Mounting of Limit Switches is critical to obtain optimum performance and ensure safety reliability.
Installation of all switches must be in accordance with a risk assessment for the individual application.
Installation must only be carried out by competent personnel and in accordance with these instructions.
1.
Never use the switch as a mechanical stop. Ensure that the actuator is protected from mechanical shock.
2.
For switches with Linear actuators the actuating direction and force from the moving object should be applied in line with the axis of the plunger.
3.
For switches with Rotary actuators or rollers the operating cam from the moving object should be designed such that the switch is never operated beyond it's over travel position. Always use a
30 degree tapered actuating cam.
4.
The heads of the switch can be rotated to obtain the best switch orientation by removing the 4 head screws and rotating the head through 90 degrees. Always ensure the 4 head screws are
tightened to 1Nm to ensure switch robustness.
Incorrect
5.
Always ensure that when fitting electrical conductors that they are routed correctly and do not interfere with the switch cover during fitting.
Maximum conductor size is 1.5 sq.mm, contact terminal tightening torque is 1Nm.
6.
Tightening torque for the lid screw is and cable glands is1Nm to maintain IP rating.
7.
Always use M4 mounting bolts and ensure 2Nm tightening torque for robust fitting.
8.
The switches are reset by pulling out the blue pin after switch actuation.
9.
The safety functions and mechanics must be tested regularly. For applications were infrequent guard access is foreseeable, the system must have a manual function test to detect a
possible accumulation of faults. At least once per month for PLe Cat3/4 or once per year for PLd Cat3 (ISO13849-1). Where possible it is recommended that the control system of the
machine demands and monitors these tests, and stops or prevents the machine from starting if the test is not done. (See ISO14119).
Maintenance:
Every Week:
Check the switch actuator and body for signs of mechanical damage and wear. Replace any switch showing damage.
Every 6 Months: Isolate power and remove cover. Check screw terminal tightness and check for signs of moisture ingress. Never attempt to repair any switch.
:
Contact Blocks /Connections
Technical Specification:
Conforming to standards
Positive Opening Operation
Utilization Category
Actuation Force/Torque for Positive Opening
Min Current
Thermal Current (Ith)
Rated Insulation Voltage
Rated Impulse Withstand Volt
Max. Switching Speed
WARNING: DO NOT DEFEAT, TAMPER, OR BYPASS THE SAFETY FUNCTION.
FAILURE TO DO SO CAN RESULT IN DEATH OR SERIOUS INJURY.
AVERTISSMENT: NE PAS DESACTIVER, MODIFIER, RETIRER, OU CONTOURNER
CETI INTERVERROUILLAGE IL PEUT EN RESULTER DES
BLESSURES GRAVES DU PERSONNEL UTILISATEUR.
LSPS-R Series - IEC Safety Limit Switches
Correct
Stop
ISO14119 IEC947-5-1 UL60947-5-1 EN50047 ISO13849-1
NC Contacts
AC15 A300 240V. 3A.
12N. linear types
1.0Nm. rotary types
5V, 5mA, DC
10A
300VAC
2500VAC
250mm/s

Operating Instructions

Incorrect
Case Material
Roller Material
Enclosure Protection
Operating Temperature
Mechanical Life Expectancy
Electrical Life Expectancy at full load
Vibration
Conduit Entry
Fixing
Original Instructions.
To request this data sheet in other languages please contact
Um dieses Datenblatt in Deutscher Sprache wenden Sie sich bitte anfordern
info@idemsafety.com
Pour obtenir cette fiche en Français, veuillez contacter
Para solicitar esta hoja de datos en Español, por favor contacto con
EN 50047
Correct
UL approved glass-filled plastic
Various Polymers Steels
IP67
Min. -25°C Max 80°C
2,500,000 Cycles
100,000 Cycle min.
IEC 68-2-6, 10-55Hz 0.35mm
M20 or ½" NPT
2 x M4
info@idemsafety.com
info@idemsafety.com
info@idemsafety.com

Advertisement

loading

Summary of Contents for Idem LSPS-R Series

  • Page 1: Operating Instructions

    Application: IDEM LSPS-R Limit Switches with Reset Button are designed to be mounted for position sensing of moving applications e.g. guard doors, conveyors, machine beds, elevators etc. They are available with linear plungers, rotary levers or roller plungers and either slow or snap action contacts. All contact blocks are positively operated to satisfy IEC 60947-5-1.
  • Page 2 MTTFd 356 years Intended for same polarity use and one polymeric conduit connection. IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070 Fax.: +44 (0)1942 257076 IDEM (USA) 4416 Technology Drive, Fremont, CA 94538 Tel:510-445-0751 Fax:1866-431-7064 email: sales@idemsafety.com...