Download Print this page

Idem IDIS-1 Operating Instructions

Safety interlock switch

Advertisement

Quick Links

IMPORTANT NOTE:
Read and understand these instructions before installing, operating, or maintaining this equipment.
The product is designed to be a component of a customised safety orientated control system. It is the responsibility of each manufacturer to ensure the correct overall
functionality of its systems and machines. IDEM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not
designed by IDEM.
Application:
IDIS-1 Tongue (Key) Interlock Switches are designed to be mounted for interlock position sensing of hinged moving guards.
They can be fitted to the leading edge of sliding, hinged or lift off guards.
They have positive opening contacts in accordance with IEC 60947-5-1 and the switch design offers a tamper resistant actuator key. They are available with either an angled or
flat actuator fixing to cover most fixing positions and contact blocks are available in slow make/break 2NC 1NO, 3NC or 1NC 1NO snap action.
Enclosures are protected to IP67.
Operation:
Operation of the switches is achieved by withdrawing the actuator key from the switch to cause deflection of the switch plunger.
Positive actuation of the contacts is achieved at 5mm withdrawal of the actuator.
Installation guide:
Correct Mounting of Interlock Switches is critical to obtain optimum performance and ensure safety reliability.
Installation of all switches must be in accordance with a risk assessment for the individual application.
Installation must only be carried out by competent personnel and in accordance with these instructions.
Warning: Do not defeat, bypass or tamper with this switch, severe injury may result.
1.
Never use the switch as a mechanical stop.
2.
To ensure that the actuator and switch are protected from mechanical shock, guides and stops must be used to prevent mechanical damage.
3.
The heads of the switch can be rotated to obtain the best switch orientation by removing the 4 head screws and rotating the head through 90 degrees. Always ensure the
4 head screws are tightened to 1Nm to ensure switch robustness. Always fit the blanking plug (supplied) to the unused actuator entry aperture.
4.
When mounting to the guard door align and fix the switch body and actuator using 2 x M4 mounting bolts tightened at 1.5Nm.
5.
Typical applications:
Hinged guard
Contact Blocks/Connections:
Slow Make Break 2NC 1NO
Quick Connect ½" UNF
IDIS-1
Sliding guard
Slow Make Break 3NC
Quick Connect (QC)
½" UNF 6 Way Male
(Connector length 14mm)
Pin view from switch
Quick Connect M12
Safety Interlock Switch
Operating Instructions
Lift off guard
Snap Action 1NC 1NO
Switch Circuit
1
5
11/12
2
6
21/22 or 23/24
3
4
33/34 or 31/32
Quick Connect (QC)
M12 8 Way Male
(on Flying Lead 250mm)
Pin view from switch
1
7
6
5
4
3

Advertisement

loading

Summary of Contents for Idem IDIS-1

  • Page 1 The product is designed to be a component of a customised safety orientated control system. It is the responsibility of each manufacturer to ensure the correct overall functionality of its systems and machines. IDEM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by IDEM.
  • Page 2 Various (see sales part numbers) Fixing 2 x M4 IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070 Fax.: +44 (0)1942 257076 Doc: 102503 IDEM (USA) 4416 Technology Drive, Fremont, CA 94538 Tel:510-445-0751 Fax:1866-431-7064 email: sales@idemsafety.com...