Paradyne 7974 Installation Instructions Manual page 21

Tdm sdsl standalone termination units
Table of Contents

Advertisement

Table 8. Communication Protocol Options
Node IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the Node IP address.
Node Subnet Mask
Possible Settings: 000.000.000.000 – 255.255.255.255
Default Setting: 000.000.000.000
Specifies the Node Subnet Mask.
Default Network Destination
Possible Settings: None, COM, DSL
Default Setting: None
Specifies where the default management network is connected. For example, if your
default network is connected to the COM port, select COM as the default
management network destination.
Communication Port IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the unit's Communication Port IP Address when the unit is configured as a
network communication link.
Communication Port Subnet Mask
Possible Settings: 000.000.000.000 – 255.255.255.255
Default Setting: 000.000.000.000
Specifies the unit's Communication Port Subnet Mask when the unit is configured as a
network communication link.
Communication Port Link Protocol
Possible Settings: PPP, SLIP
Default Setting: PPP
Specifies the unit's Communication Port link layer protocol when the unit is configured
as a network communication link.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

79757976Hotwire 7974-a2Hotwire 7975-a2Hotwire 7976-a2

Table of Contents