Download Print this page

Advertisement

Quick Links

Version
Last updated
1.3
03/07/2023
Hampton 5 Insert
Technical Information covering Hampton 5 Insert
ADDRESS
CONTACT
Ecosy+
Telephone: + 44 1256 830099
Unit 22,26, Folly Farm,
Email: trade@ecosystoves.co.uk
Ramsdell
Tadley, Hampshire
RG26 5RJ
Brought to you by
United Kingdom
Ecosy+ Stoves, Hampshire

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hampton 5 Insert and is the answer not in the manual?

Questions and answers

Summary of Contents for Ecosy+ Hampton 5 Insert

  • Page 1 Version Last updated 03/07/2023 Hampton 5 Insert Technical Information covering Hampton 5 Insert ADDRESS CONTACT Ecosy+ Telephone: + 44 1256 830099 Unit 22,26, Folly Farm, Email: trade@ecosystoves.co.uk Ramsdell Tadley, Hampshire RG26 5RJ Brought to you by United Kingdom Ecosy+ Stoves, Hampshire...
  • Page 2 DEAR CUSTOMER, To ensure you get the most out of your fire for the longest time, please Congratulations and thank you for purchasing a Hampton 5 Insert stove. take the time to have a read through the attached manual. Hampton stoves boast some amazing technology that means this range...
  • Page 3 To enable a good flow of air through the appliance to reduce condensation and subsequent damage, leave the air controls fully open. Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is in use. 2 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 4 TECHNICAL INFORMATION AND TECHNICAL DRAWING - COVERING THE HAMPTON 5 INSERT HAMPTON 5 INSERT Outlet Size 5” Defra Approved Nominal Output Efficiency DIN Plus Dust (at 13% O2) Mean NOX (at 13% O2) Mean CnHm (at 13% O2) Mean CO emissions (at 13% O2) 0.07...
  • Page 5 4 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 6 Hampton 5 Insert – Exploded Drawing 1. Handle. 2. Cast iron door. 3. Glass 4. Cast iron fascia 5. Right 11. Top vermiculite baffle brick. 12. Cast iron secondary air casing side vermiculite brick . 6. Left side vermiculite brick 7. Primary at the rear 13.
  • Page 7 The appliance shall be installed on a floor with adequate load- bearing capacity. If the existing construction does not meet this requirement, suitable measures (e.g., load distributing plate) should be provided to achieve it. 6 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 8 If you are worried about damp issues, we would suggest a pumice backfill ( Leca ) – 7 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 9: Air Controls

    This must remain in place if you require the stove to be Defra approved. When you light the fire, you want to ensure this is fully open. As the fire becomes more established this can be closed off. (To learn how to use the controls, please see page 13 ) 8 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 10 Operation with door left open Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open except as directed in the instructions. 9 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 11: The Clean Air Act 1993 And Smoke Control Areas

    The Hampton 5 Insert has been recommended as suitable for use in smoke control areas when burning seasoned wood logs. Each appliance has been factory fitted with a screw that prevents the full closure of the Tertiary and Secondary air inlets. In a smoke control area the air control stop must be fitted.
  • Page 12 Refueling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there are too few embers in the fire bed add suitable kindling to prevent excess smoke. 11 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 13 If the temperature in the stove is too low, the glass will begin to go black and excess smoke will be produced. Often the key to a hot firebox is the burning of quality dry fuel. 12 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 14: Cleaning And Maintenance

    If your fire rope has become frayed and is no longer making good contact it will need replacing. To change the rope, we suggest removing the door and laying it flat. To remove the door, you need to lever up the bottom door pin, that will have a small head on it. 13 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 15 For full guarantee details please visit . With every claim we will require a signed copy of www.ecosystoves.co.uk the sign-off sheet. 14 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 16 We only suggest changing bricks when they have crumbled away, exposing the stove’s body. 15 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 17 Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 8423:2002 (Replaces BS 6539) in the presence of children, aged and/or infirm persons. 16 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099...
  • Page 18 •Dispose of the items correctly i.e., separate the parts to be disposed of in material groups. •Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling and disposal technology. 17 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 19 18 of 18 Hampton 5 Insert ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...