  • Page 1 Installation and Operating Instructions Wood-burning Stove Ottawa 5kw Model: Size: W390XD430XH560MM...
  • Page 2 INTRODUCTION Wood-burning Stove Item No.: Ottawa 5kw Size: W390XD330XH560MM SAFETY Safety is the most important consideration when using and installing your stove. If not installed and used correctly, a house fire could result. Installation must comply with relevant national and local Building Regulations and fire safety standards.
  • Page 3: Installation

    INSTALLATION Installation of your stove must comply with relevant local and national Building Regulations and fire safety standards. TECHNICAL Ottawa 5 kW - Performance Test Results. All efficiencies in table are Net values Wood Results, 1 hour refuels Parameter Mean Test Duration h 1.05 Total Efficiency...
  • Page 4: Operating Instructions

    If installed in a standard type chimney, a register plate needs to be fitted inside the chimney. When purchasing flue pipe, 5” diameter is required. The flue pipe must be fitted INSIDE the flue spigot, and sealed with a generous amount of Fire Cement. Access should be provided for cleaning the flue to ensure that the passageways for exhaust gases remain free from obstruction.
  • Page 5: Air Inlet Controls

    this will usually be 18 months+. It is recommended that logs should be no more than 5” or 125mm in diameter. If you are unsure of the moisture content of your fuel, then you can buy a moisture meter which will indicate the moisture levels in your fuel. Liquid fuels must NEVER be used.
  • Page 6 ade. any applicable local regulations as well as these installation instructions. een tested at nominal output with a flue draught of 12 Pa) INITIAL CURING AND TEMPERING FIRES ESSENTIAL INSTRUCTIONS BEFORE USE – It is essential to follow these ‘tempering-in’ instructions in order to avoid serious damage to your stove.
  • Page 7 First use troubleshooting. When the stove is new the paint is very tacky where the stove is curing. The door locks very tight and when opened can pull away the fire rope from its chamber. If the instructions are followed above this should not happen. However if it does the rope will need to be stuck back in place with “heat resistant fire rope glue”...
  • Page 8: Cleaning & Maintenance

    down draughts, it may be difficult to get sufficient draw through the appliance to achieve good combustion. When this happens, the stove should not be used. IMPORTANT: - As of October 2010, it is a legal requirement to use a Carbon Monoxide Detector in the same room as the stove.