Ecosy+ Ottawa 5 ECO Wide Manual

Hide thumbs Also See for Ottawa 5 ECO Wide:

Advertisement

Quick Links

Version
Last updated
1.2
04/03/2020
Ottawa 5 ECO Wide
&
OTTAWA DELUXE WIDE
Technical Information covering Hampton Vista 500
ADDRESS
CONTACT
Ecosy+
Telephone: + 44 1256 830099
Unit 24, Folly Farm, Ramsdell
Email: trade@ecosystoves.co.uk
Tadley, Hampshire
RG26 5RJ
United Kingdom
Brought to you by
Ecosy+ Stoves, Hampshire

Advertisement

Table of Contents
loading

Summary of Contents for Ecosy+ Ottawa 5 ECO Wide

  • Page 1 Version Last updated 04/03/2020 Ottawa 5 ECO Wide & OTTAWA DELUXE WIDE Technical Information covering Hampton Vista 500 ADDRESS CONTACT Ecosy+ Telephone: + 44 1256 830099 Unit 24, Folly Farm, Ramsdell Email: trade@ecosystoves.co.uk Tadley, Hampshire RG26 5RJ United Kingdom Brought to you by...
  • Page 2: Table Of Contents

    CONTENTS WELCOME ..................................... 2 SAFETY ......................................2 TECHNICAL INFORMATION ................................3 EXPLODED DRAWINGS …………………………………………………………………………………………………………….4 TECHNICAL DRAWINGS …………………………………………………………………………………………………………………………..5 ASSEMBLY ..................................... 5 FLUE PIPE ON TOP ......................................6 FLUE PIPE AT REAR ......................................6 HEARTH ......................................7 AIR SUPPLY / VENTILATION / CHIMNEY DRAW ..........................9 CHIMNEY LINING ..............................
  • Page 3: Welcome

    WELCOME DEAR CUSTOMER, To ensure you get the most out of your fire for the longest time, please Congratulations and thank you for purchasing your Ottawa stoves take the time to have a read through the attached manual. The Ottawa range was Ecosy+ stoves opening collection back in 2015. This Yours Truly, range is a firm favorite by the general public and stove installer alike.
  • Page 4: Technical Information

    TECHNICAL INFORMATION OTTAWA 5 ECO WIDE / OTTAWA DELUXE WIDE Outlet Size 5” Defra Approved Nominal Output Efficiency 83.4% DIN Plus Dust (at 13% O2) 7 Nmg/m3 Mean NOX (at 13% O2) 100 Nmg/m3 Mean CnHm (at 13% O2) 48 Nmg/m3 Mean CO emissions 0.10%...
  • Page 5: Exploded Drawings

    EXPLODED DRAWING: OTTAWA DELUXE WIDE AND OTTAWA 5 WIDE 1. Cast iron door 2. Handle 3. Heat resistant glass 4. Top steel 11. External body. 12. Casing which includes secondary air holes slider plate 5. Right side fire brick. 6. Cast iron Air wash casing 7. 13.
  • Page 6: Technical Drawings

    DRAWING FOR OTTAWA 5 WIDE DRAWING FOR OTTAWA DELUXE WIDE SIGNATURE 5 ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 7: Assembly

    ASSEMBLY Your stove is fully built and almost ready to go. All you need to do is attach the flue collar that is boxed inside the fire, marked “Chimney”. FLUE PIPE ON TOP If you are attaching the flue to the top of the stove, you will need to remove the blanking plate that is currently on top. To do this you will need a Philips screwdriver and 10mm spanner.
  • Page 8: Hearth

    HEARTH The whole Signature range is suitable for a 12mm free standing, non-constructional hearths - see diagram below, marked (b). This is allowed because each model’s base does not exceed 100°C. The hearth must be made from a non-combustible material strong enough to stand the weight of the fire.
  • Page 9 SIGNATURE 5 ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...
  • Page 10: Air Supply / Ventilation / Chimney Draw

    AIR SUPPLY / VENTILATION / CHIMNEY DRAW Your stove will require a constant air supply and should not be used at the same time and in the same room/space as extractor fans or any device which may draw air supply away from the stove. This model has a nominal output of 5kw and in most cases an air brick is not required.
  • Page 11: Air Control

    AIR CONTROL Air wash / Tertiary: This is the control just above the door. When slid to the right, air is flowing in and slid to the left air is restricted. This control manages the air flowing over the glass and helps to keep it clean and clear of smoke stains. To begin with this will need to be left open.
  • Page 12: Smoke Free Zones

    The Ottawa 5 Eco Wide and Ottawa Deluxe Wide have been recommended as suitable for use in smoke control areas when burning seasoned wood logs. Each appliance has been factory fitted with a screw that prevents the full closure of each vent. In a smoke control area the air control stop must be fitted.
  • Page 13: Fuel

    FUEL Wood- All types of wood are suitable provided they are well seasoned, UNTREATED, and have a moisture level between 12% and 20%. For soft woods, typically they will need to have been left in suitable storage for 9+ months for the moisture to evaporate. For hardwoods, this will usually be 18 months+.
  • Page 14: Lighting My Stove

    LIGHTING MY STOVE Prior to lighting the fire for the first time, ensure that • Installation and building work is complete. • The chimney is suitable and sound and has been swept and free from obstruction. • Adequate ventilation and provision for combustion air has been made. •...
  • Page 15: First Use Troubleshooting

    FIRST USE TROUBLESHOOTING When the stove is new the paint is very tacky where the stove is curing. The door locks very tightly and when opened can pull away the fire rope from its chamber. If the instructions are followed above this should not happen. However, if it does, the rope will need to be stuck back in place with “heat resistant fire rope glue”...
  • Page 16: Cleaning And Maintenance

    CLEANING AND MAINTENANCE When cold, the inside of the stove should be given a regular sweep out. The flue and flue pipe will require cleaning with a suitable chimney brush, to minimise build-up of soot and tar. Your chimney will also require periodic sweeping.
  • Page 17: Guarantee

    GUARANTEE The main body of your stove is guaranteed for 5 years. Incorrect use or installation not carried out by a registered HETAS installer will void the guarantee. The only exceptions will be if the install has been signed off by your local authority or suitably qualified Oftec installer. In addition to this the stove must be serviced annually by a suitably accredited chimney sweep or stove installer.
  • Page 18: Broken Fire Bricks

    BROKEN FIRE BRICKS It is common for vermiculite bricks to break. They are fully heat resistant but can be quite fragile. The most common bricks to break are the base and back bricks as these take the brunt of abuse. To ensure the longevity of your fire bricks, please ensure that you gently place fuel in the fire and do not over stack fuel.
  • Page 19: Broken / Crazed Glass

    BROKEN / CRAZED GLASS The glass used in all fires is fully approved heat resistant ceramic glass. This glass will not break through heat but can easily break if struck with a log or similarly hard object. This is why the glass is not covered by any manufacturer of stoves. Common causes for glass breakages are customers closing the door when a log is still sticking out.
  • Page 20: Energy Efficiency

    ENERGY EFFICIENCY SIGNATURE 5 ecosystoves.co.uk + 44 1256 830099 trade@ecosystoves.co.uk...

This manual is also suitable for:

Ottawa deluxe wide

Table of Contents