Download Print this page

Haier HHX3030SS User Manual page 9

Advertisement

Blower Installation
1. When reinstalling the blower into the hood, you will have to mount the blower in
the same direction you have ducted it (horizontal, vertical or ductless).
2. Using the 4 nuts removed earlier, secure the blower in place. Start the nuts by
hand first, then tighten with a 3/8" nut driver or ratchet. A 3/8" ratchet with an
extension will make this operation easier.
3. Plug the blower into the appropriate connector on the side of the wire
compartment.
Note: For ductless installation, remove the range hood's vent insert from the front
grille.
Preparation for Duct Connection
1. Remove the appropriate ducting knockout by inserting a screwdriver under one
end and prying it up. Then snip or break the attachment points.
2. Install the damper assembly to the range hood with the 2 screws supplied (fig. 2).
3. If discharge is vertical through a rectangular duct, remove the knockout sections
D, B and E only (Fig. 4).
4. If the vertical discharge is through a 7" round duct, remove knockout sections
"A" and "B" and "C" only (Fig. 4).
Note: Section "D" and "E" remain with the hood.
5. Mount the round collar (E22A -not supplied) over the opening on the hood by
using 3 shorter screws. Allow the bottom edge of the 7" duct to be inserted into
the collar.
fig. 3
fig. 4
English
8

Advertisement

loading

This manual is also suitable for:

Hhx3030