COMSPHERE DualFlow Data Service Units
DSR FrcOn: Enab
Next
Enab
Disab
Data Set Ready Forced On . Provides the ability to override any other options controlling the Data Set Ready lead.
Enab
DSR remains ON as long as the device is working regardless of tests and network alarms.
Disab
DSR functions as an active lead reflecting various test and alarm conditions and other options.
DSR on Tst: Enab
Next
Enab
Disab
Data Set Ready On in Test . Controls the behavior of the DSR lead during testing.
Enab
DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test
messages to the DBM.
Disab
DSR is Off during testing.
RespondRDL: Disab
Next
Enab
Disab
Respond to Remote Digital Loopback . Determines whether the DBM responds to a V.54 Remote Loopback request.
Enab
Performs a Digital Loopback.
Disab
Ignores the Loopback command.
RL by DTE: Disab
Next
Enab
Disab
Remote Digital Loopback by DTE . Allows Pin 21 of the EIA-232-D/V.24 interface or Pin N of the V.35 interface by the
DTE or router to initiate a Remote Digital Loopback.
NOTE: Use of Pin 18 or Pin L is determined by the DBM's DTE Port configuration option.
Enab
The DTE or router forces the DBM to request a Remote Digital Loopback when the signal on Pin 21 or
Pin N is turned ON. Remote Digital Loopback ends when the signal is dropped.
Disab
The DTE or router cannot initiate Remote Digital Loopback.
Bilat Lpbk: Disab
Next
Enab
Disab
Bilateral Loopback . If this configuration option is enabled, a DTE Loopback occurs when a Digital Loopback occurs.
Enab
When enabled, DTE Loopback occurs whenever a Digital Loopback occurs.
Disab
Disables Bilateral Loopback.
Ext Leads: Rate
Next
ExtLd
Rate
External Leads . Controls the general-purpose leads on the EIA-232-D/V.24 interface except when Rate is selected.
These leads can be controlled and monitored from the DCP or a 6700 or 6800 Series NMS.
ExtLd
Enables Pins 12 and 13 as output (control) and Pins 19 and 23 as input (alarm) leads. When enabled,
Pins 12 and 13 output +12V when ON and –12V when Off. Pins 19 and 23 recognize voltages from +2.2V
to +12V as ON (reported as an External alarm) and –12V to +.8V as Off.
Rate
Pin 12 on the port is turned Off to indicate that the DBM is in fallback mode. If the port does not fall back
and remain at the same speed, then the fallback feature in the DCE or router connected to that port
should not be enabled.
RPowr —
Functions similarly to ExtLd, but the inputs report power failure or fan alarms when a redundant power
supply is installed in the COMSPHEREr 3000 Series Carrier.
5-14
Table 5-4
(2 of 3)
DBM Port Configuration Options
Prev
Prev
Prev
Prev
Prev
RPowr
Prev
July 1999
3615-A2-GB20-40