Paradyne COMSPHERE DualFlow 3615 User Manual page 76

Data service units
Hide thumbs Also See for COMSPHERE DualFlow 3615:
Table of Contents

Advertisement

COMSPHERE DualFlow Data Service Units
LSD Lead: Std
Next
Std
Delay
Line Signal Detect Lead . Controls behavior of the Line Signal Detect lead.
Std
LSD lead goes Off in response to a control mode idle (CMI) signal from the DDS network or DDS failure.
Delay
LSD does not go Off in response to a network alarm condition or CMI. LSD goes Off only after a
successful backup connection is established.
FrcOn —
Keeps LSD on as long as the DSU has power.
DSR FrcOn: Enab
Next
Enab
Disab
Data Set Ready Forced On . Provides the ability to override any other options controlling the Data Set Ready lead.
Enab
DSR remains ON as long as the device is working, regardless of tests and network alarms.
Disab
DSR functions as an active lead reflecting various test and alarm conditions and other options.
SystemStat: Enab
Next
Enab
Disab
System Status . Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or Out-of-Frame alarm
from the network.
Enab
Network alarm turns Off DSR.
Disab
Network alarm does not affect DSR.
DSR on Tst: Enab
Next
Enab
Disab
Data Set Ready On in Test . Controls the behavior of the DSR lead during testing.
Enab
DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test
messages to the DSU.
Disab
DSR is Off during testing.
Circ Assur:Disab
Next
Enab
Disab
Circuit Assurance . Controls behavior of the CTS lead in response to a data signal from the network. If CTS Cntrl is set to
RTS and RTS Cntrl is set to FrcOn, this configuration option is ignored.
A DDS Facility Alarm condition turns Off the CTS lead, regardless of the Circuit Assurance setting.
Enab
The DSU will turn Off the CTS lead if the DSU receives control mode idle (CMI) from the network.
Disab
The DSU is not affected by the receipt of CMI.
RespondRDL:Disab
Next
Enab
Disab
Respond to Remote Digital Loopback . Determines whether the DSU responds to a V.54 Remote Loopback request.
Enab
Performs a Digital Loopback.
Disab
Ignores the Loopback command.
5-8
Table 5-2
(2 of 3)
DSU Port Configuration Options
FrcOn
Prev
Prev
Prev
Prev
Prev
Prev
July 1999
3615-A2-GB20-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere dualflow 3616

Table of Contents