LUBRICATION (ZX210LC-
CAUTION: Position the machine as illustrated below
for lubrication. Stop the engine. Move the pilot con-
trol shut-off lever to the LOCK position. Attach a "Do
not Operate" tag to an easy-to-see place such as the
cab door or a control lever to prevent the machine
from being unintentionally operated while repairs
are being performed.
5
4
3
2
1
Central
Greasing
Location
A
Respectively
Precautions for Greasing
• Grease only after cleaning the grease fitting.
• Grease parts having no grease fittings such as the levers, links at their proper intervals.
• Use only the same manufacturer's grease.
• Part failure may result if greasing is not performed or the filter elements are not replaced at the specified intervals. Be
sure to service the machine as specified.
, 250LC-
, 350LC-
3
3
2
5
4
3
M1V1-SH1-023
No.
Greasing Part
1
Boom Foot
2
Boom Cylinder Rod
3
Arm Cylinder Bottom
4
Arm Boss
5
Arm Cylinder Rod
6
Arm
MAINTENANCE
)
3
A
8-7
6
Interval
Quan-tity
(Hours)
2
2
2
8
2
2
2
M1V1-SH1-025
Kind of Grease
Bearing Grease