NMS Alarm Outputs
CO alarms can be sent to a Modular 3611 DSU (which
will then notify a 6800 Series NMS) via a 6-wire modular
jack on the CO Power Unit's backplane (see Figure A-1).
(The Modular 3611 DSU must be configured to forward
alarms to a 6800 Series NMS.) Table A-4 lists the pin
assignments for the NMS adapter cable. Figure A-3
illustrates the NMS adapter cable.
Note that a power failure alarm signal is sent to an
NMS upon a failure in either the – 48V input or low
1
All other pins on the 25-pin male connector are wired straight through
to the 25-pin female connector.
2
This pin only functions as a +12 Vdc source when Jumper J21 is set
as shown in Figure 2-10 of Chapter 2.
3000-A2-GB41–50
Pin Assignments for the NMS Adapter Cable
EIA 25-Pin
1
Male End
2
1
11
14
16
19
23
voltage output circuits, and that a fan failure alarm signal
is sent if the fan speed falls below 1900 rpm.
To avoid potential problems
caused by incorrect connections
(e.g., grounding the +12 Vdc
source), do not set Jumper J21
as shown in Figure 2-10 of
Chapter 2 if you are not using
an NMS adapter cable.
Table A-4
Modular
NMS Alarm Function
Plug End
6
+12 Vdc Source
4
None
3
None
5
None
2
Fan Status Alarm
1
Power Status Alarm
October 2002
Interface Connections
NOTE
A-5