Clearance to non-mechanical air supply inlet to building or the
combustion air inlet to any other application
K
Clearance to mechanical air supply inlet
L
Clearance above paved sidewalk or paved driveway located on
public property
M
Clearance under veranda, porch deck or balcony
1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2) If locally adopted installation codes specify clearances different than those illustrated, then the most stringent clearance shall
prevail.
3) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code
4) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and
serves both dwellings.
5) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
Table 20
[*]
For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated:
a) A minimum clearance value determined by testing in accordance with section 2.20, or;
b) A reference to the following footnote:
"Clearance in accordance with local installation codes and the requirements of the gas supplier."
830 ES – 6 720 644 936 (2021/08)
Canadian
1)2)
installations
36 in.
72 in.
4)
84 in.
5)
12 in.
Installation instructions
2)3)
U.S. installations
4 feet below or to side of
opening;
1 foot above opening
36 in. above if within 10 feet
horizontally
84 in.
*
23