Installation; Site Requirements; Installation Overview - MSI EV Series User Manual

Table of Contents

Advertisement

Installation

Before installing the EVSE, please ensure that the installation site meets the following
requirements.

Site Requirements

∙ The installation site should be dry, well-ventilated, and free from direct exposure to
sunlight.
∙ The installation site should have a flat and stable surface that can support the
weight of the EVSE.
∙ The installation site should be easily accessible to authorized personnel and away
from any potential hazards.
∙ The installation site should have a power supply with appropriate voltage and
current ratings to power the EVSE.
∙ The installation site should have proper grounding according to local electrical
codes and regulations.

Installation Overview

230 mm
* Recommended installation space Installers shall follow applicable accessibility
requirements for the mounting position. The EVSE shall be mounted at a height
between 600 mm (23.6 inches) and 1200 mm (47.2 inches) above ground.
** The EV AI requires the installation of the Wall Mount bracket at a distance of 760
mm (29.9 inches) from the ground to ensure proper detection of the license plate by
the camera.
250 mm
Ground/Floor
7
152 mm
196 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ev lifeEv life plusEv premiumEv ai

Table of Contents