Download Print this page

Pentair FRESHPOINT F3000-B2B Instruction Manual page 10

Hide thumbs Also See for FRESHPOINT F3000-B2B:

Advertisement

Available languages

Available languages

PERFORMANCE DATA
Important Notice: Read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test Conditions
Flow Rate
F3000-B2B
= 0.60 gpm (2.27 L/min)
F3000-B2M
= 0.60 gpm (2.27 L/min)
Filter Capacity
F3000-B2B
= 675 gallons (2555 L)
F3000-B2M
= 675 gallons (2555 L)
Inlet Pressure
= 60 psi (4.1 bar)
Temperature
= 68°F +/- 5°F (20°C+/- 2.5°F)
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating Requirements for F3000-B2B and F3000-B2M Systems:
Pressure
= 40-100 psi (2.75-6.89 bar)
Temperature
= 40-100°F (4.4–37.8°C)
CARTRIDGE SEQUENCE
F3000-B2B
10 • F3000-B2B, F3000-B2M Filtration Systems Instruction Manual
F3000-B2M
262.634.2386 | greatlakesintl.com
F3000 B2B, F3000 B2M SYSTEMS
INSTALLED WITH F2B2 RC2 FILTER
CARTRIDGE SET AND F1S5 RC
CARTRIDGE
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Conforms to NSF/ANSI 53 for VOC reduction. See performance data
sheet for individual contaminant and reduction performance.
Model F3000-B2B, F3000-B2M Systems
Max. Permissible
Influent Challenge
Substance
Product Water
Concentration
Concentration
Standard 42
Chlorine Taste
2.0 mg/L±10%
& Odor
Particulates (0.5-
at least 10,000
<1uM) Class 1*
particulates/mL
Standard 53
Cysts **
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Lindane
0.002 mg/L ± 10%
Chloroform
(VOC surrogate
0.300mg/L ± 10%
chemical)
Perfluorooctanoic
Acid (PFOA) and
0.0015 mg/L ± 10%
Perfluorooctane
Sulfonate (PFOS)
Flow Rate = 0.6 gpm (2.2 L/min); Capacity = 675 gallons (2555 L) or 12
months
Testing was performed under standard laboratory conditions, actual
performance may vary.
* Reduces particles as small as 0.5-1 micron in size by mechanical
means
** NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
EPA Est. No. 082989-CHN-001
The Models F3000-B2B and F3000-B2M are Tested and Certified by NSF
International against NSF/ANSI Standard 42, 53, and CSA B483.1 for the reduction
of substances specified on the Performance Data Sheet.
C
US
The Models F3000-B2B and F3000-B2M are certified by IAPMO R&T against NSF/
ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane
sulfonate (PFOS).
Reduction
Minimum
Requirements
Reduction
Reduction
≥50%
>85%
99.95%
99.97%
0.003 mg/L
90.5%
0.010 mg/L
99.3%
0.010 mg/L
99.3%
0.0002 mg/L
94.8%
0.015 mg/L
96.5%
0.00007 mg/L
96.27%
Average
95.9%
97.9%
99.99%
93.7%
99.9%
99.6%
97.4%
98.8%
98.06%